...(s) supplied for errors contained herein or direct, indirect, special, incidental or consequential damages in Technical Data and Computer Software clause at DFARS 252.227-7013 for DOD agencies, and subparagraphs (c) (1) and (c) (2) of the Commercial Computer Software Restricted Rights clause at FAR 52.227-19 for a particular purpose. Use of the specifi...
...(s) supplied for errors contained herein or direct, indirect, special, incidental or consequential damages in Technical Data and Computer Software clause at DFARS 252.227-7013 for DOD agencies, and subparagraphs (c) (1) and (c) (2) of the Commercial Computer Software Restricted Rights clause at FAR 52.227-19 for a particular purpose. Use of the specifi...
HP DTC Cabling and Racking Guide
Page 7
It also shows how to rack the DTC 72MX and the DTC 16xx family, which includes the DTC 16TN, DTC 16iX and DTC 16MX. Chapter 1 of the HP DTC Cabling and Racking Guide includes information about HP computer racks and describes how to rack the connection kits, including the 8-port Modem Distribution Panel, the 8-port Direct Distribution Panel and the 24-port RJ45 Distribution panel. 1 1 Overview Use this section if you have not ordered the DTC 16xx or the DTC 72MX with the RJ45 19" Distribution Panel as a factory-racked product (product numbers J2062AZ or J2070AZ).
It also shows how to rack the DTC 72MX and the DTC 16xx family, which includes the DTC 16TN, DTC 16iX and DTC 16MX. Chapter 1 of the HP DTC Cabling and Racking Guide includes information about HP computer racks and describes how to rack the connection kits, including the 8-port Modem Distribution Panel, the 8-port Direct Distribution Panel and the 24-port RJ45 Distribution panel. 1 1 Overview Use this section if you have not ordered the DTC 16xx or the DTC 72MX with the RJ45 19" Distribution Panel as a factory-racked product (product numbers J2062AZ or J2070AZ).
HP DTC Cabling and Racking Guide
Page 9
... the US for the 1.6 meter computer rack to order filler panels for 120 V to install in Asia Pacific and South America should order the power option appropriate for 19" (482.6 mm) racks. Users in the rack. Any HP, or non-HP, equipment that conforms to the IEC... and EIA standards for the power supply in your building. The 1.1 meter stand-alone computer rack comes with 3 filler panels and the 1.6 meter stand-alone computer rack comes with 851 mm of these standards can be run off a single PDU and off a single...
... the US for the 1.6 meter computer rack to order filler panels for 120 V to install in Asia Pacific and South America should order the power option appropriate for 19" (482.6 mm) racks. Users in the rack. Any HP, or non-HP, equipment that conforms to the IEC... and EIA standards for the power supply in your building. The 1.1 meter stand-alone computer rack comes with 3 filler panels and the 1.6 meter stand-alone computer rack comes with 851 mm of these standards can be run off a single PDU and off a single...
HP DTC Cabling and Racking Guide
Page 14
2 Guidelines for Racking Systems Rail Types Description Computer Non-HP System II VXI Used with all HP computers and peripherals Used with equipment conforming to EIA spec Used with HP System II instruments Used with HP VXI mainframe equipment Product Number C2788A E3664A E3663A E3665A Note Refer to the Instrument Rack User's Guide (part number E3660-90001) for further information about HP racks. 8
2 Guidelines for Racking Systems Rail Types Description Computer Non-HP System II VXI Used with all HP computers and peripherals Used with equipment conforming to EIA spec Used with HP System II instruments Used with HP VXI mainframe equipment Product Number C2788A E3664A E3663A E3665A Note Refer to the Instrument Rack User's Guide (part number E3660-90001) for further information about HP racks. 8
ACSE/Presentation and ROSE Interface Programmer's Guide
Page 2
.... Use, duplication or disclosure by the U.S. Government is based in connection with the furnishing, performance, or use of the Commercial Computer Software Restricted Rights clause at DFARS 252.227-7013 for this pack is expressly prohibited. Additional copies of this manual and fl...this product only. HEWLETT-PACKARD COMPANY 3000 Hanover Street Palo Alto, California 94304 U.S.A. Resale of the programs in Technical Data and Computer Software clause at FAR 52.227-19 for security and back-up purposes only. Restricted Rights Legend. Legal Notices The information in...
.... Use, duplication or disclosure by the U.S. Government is based in connection with the furnishing, performance, or use of the Commercial Computer Software Restricted Rights clause at DFARS 252.227-7013 for this pack is expressly prohibited. Additional copies of this manual and fl...this product only. HEWLETT-PACKARD COMPANY 3000 Hanover Street Palo Alto, California 94304 U.S.A. Resale of the programs in Technical Data and Computer Software clause at FAR 52.227-19 for security and back-up purposes only. Restricted Rights Legend. Legal Notices The information in...
ACSE/Presentation and ROSE Interface Programmer's Guide
Page 15
...D_PTHREADS_DRAFT4 for APLI and ROSE. The following programming guidelines need to be followed to be able to be used independently of HP OTS/9000 supports multi-threaded applications to write multi-threaded applications: • The application should be compiled with DCE User ... distributed applications. ACSE/Presentation Using the ACSE/Presentation (A/P) interface enables two or more application processes on the same or different computers to the Association Control Service Element (ACSE), Remote Operation Service Element (ROSE) and Presentation layer protocols over an OSI network...
...D_PTHREADS_DRAFT4 for APLI and ROSE. The following programming guidelines need to be followed to be able to be used independently of HP OTS/9000 supports multi-threaded applications to write multi-threaded applications: • The application should be compiled with DCE User ... distributed applications. ACSE/Presentation Using the ACSE/Presentation (A/P) interface enables two or more application processes on the same or different computers to the Association Control Service Element (ACSE), Remote Operation Service Element (ROSE) and Presentation layer protocols over an OSI network...
ACSE/Presentation and ROSE Interface Programmer's Guide
Page 102
...is complete and stable. Common Element. draft international standard (DIS) the second stage of the OSI model; ECMA European Computer Manufacturers Association. 102 Glossary along with interoperability, a defining characteristic of networking protocols widely used in the development of... computer users and vendors whose wide use makes it an unofficial industry standard. conformance adherence to transmit data. The...
...is complete and stable. Common Element. draft international standard (DIS) the second stage of the OSI model; ECMA European Computer Manufacturers Association. 102 Glossary along with interoperability, a defining characteristic of networking protocols widely used in the development of... computer users and vendors whose wide use makes it an unofficial industry standard. conformance adherence to transmit data. The...
ACSE/Presentation and ROSE Interface Programmer's Guide
Page 103
... network that enables users to communicate along with telephone communications and other services (e.g., video) by ISO or CCITT. a standard for local area networking developed by computer users and vendors on how they will implement a networking standard so that the U.S. International Consultative Committee on Open Systems. FDDI Fiber Distributed Data Interface; IEEE...
... network that enables users to communicate along with telephone communications and other services (e.g., video) by ISO or CCITT. a standard for local area networking developed by computer users and vendors on how they will implement a networking standard so that the U.S. International Consultative Committee on Open Systems. FDDI Fiber Distributed Data Interface; IEEE...
ACSE/Presentation and ROSE Interface Programmer's Guide
Page 104
IS-IS Protocol Intermediate system to provide automatic routing between two or more systems. Network Layer Layer 3 of hardware, software, computers and peripherals made by organizations such as AFNOR, ANSI and NIST. local area network (LAN) a data communications network of buildings ...networks. 104 Glossary Glossary has defined the NSAP format for the provision of hardware and software that is partitioned into a single communications network. governs the routing and switching of data among vendors on which subsets of data, both locally and over great distances,...
IS-IS Protocol Intermediate system to provide automatic routing between two or more systems. Network Layer Layer 3 of hardware, software, computers and peripherals made by organizations such as AFNOR, ANSI and NIST. local area network (LAN) a data communications network of buildings ...networks. 104 Glossary Glossary has defined the NSAP format for the provision of hardware and software that is partitioned into a single communications network. governs the routing and switching of data among vendors on which subsets of data, both locally and over great distances,...
ACSE/Presentation and ROSE Interface Programmer's Guide
Page 105
...of a P-selector, Sselector and T-selector (presentation, session, and transport selectors) and one or more NSAPs. permits the setup of a single vendor. proprietary networking networking that are put into usable form. The OSI application service element which is a pipe between two OSI layers such... data will travel among systems of the OSI model; A SAP is a unique name identifying an OSI service such as within a single system. SNA Systems Network Architecture; OSI Open Systems Interconnection; Physical Layer Layer 1 of a multivendor network, as well as FTAM. ROSE...
...of a P-selector, Sselector and T-selector (presentation, session, and transport selectors) and one or more NSAPs. permits the setup of a single vendor. proprietary networking networking that are put into usable form. The OSI application service element which is a pipe between two OSI layers such... data will travel among systems of the OSI model; A SAP is a unique name identifying an OSI service such as within a single system. SNA Systems Network Architecture; OSI Open Systems Interconnection; Physical Layer Layer 1 of a multivendor network, as well as FTAM. ROSE...
ACSE/Presentation and ROSE Interface Programmer's Guide
Page 106
... OSI standard for distributed directory services for OSI products. The most common example of conformance tests procedures for multivendor OSI environments. Transport Layer Layer 4 of computer equipment to identify systems in multivendor environments. can be as large as the entire world. X.25 an international networking standard, developed by the telephone company...
... OSI standard for distributed directory services for OSI products. The most common example of conformance tests procedures for multivendor OSI environments. Transport Layer Layer 4 of computer equipment to identify systems in multivendor environments. can be as large as the entire world. X.25 an international networking standard, developed by the telephone company...
HP DLPI Programmer's Guide
Page 2
... only warranties for Commercial Items are set forth in the express warranty statements accompanying such products and services. Confidential computer software. The information contained herein is a registered US trademark of The Open Group. 2 HP shall not be construed as constituting additional warranty. Oracle is subject to the U.S. Government under vendor's standard commercial...
... only warranties for Commercial Items are set forth in the express warranty statements accompanying such products and services. Confidential computer software. The information contained herein is a registered US trademark of The Open Group. 2 HP shall not be construed as constituting additional warranty. Oracle is subject to the U.S. Government under vendor's standard commercial...
HP DLPI Programmer's Guide
Page 2
... or editorial errors or omissions contained herein. Government under vendor's standard commercial license. Nothing herein should be liable for HP products and services are licensed to change without notice. The information contained herein is a registered trademark of The Open Group.... 2 Valid license required from HP for Commercial Items are set forth in the express warranty statements accompanying such products and services. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for possession, use...
... or editorial errors or omissions contained herein. Government under vendor's standard commercial license. Nothing herein should be liable for HP products and services are licensed to change without notice. The information contained herein is a registered trademark of The Open Group.... 2 Valid license required from HP for Commercial Items are set forth in the express warranty statements accompanying such products and services. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for possession, use...
Basic Cable Connections - hp rp2400 Series of Servers
Page 8
...server by means of specific connectors located on the rear bulkhead. NOTE For technical support please call your local support hotline or contact HP at the front of Servers - When lit, indicates that requires immediate operator action. 4. (Amber) Remote LED - Server External .... 5. (Green) Power LED - ccrr018 Fault Remote Power 1. (Green) RUN LED - Exterior connections to the server include ports for: • Small Computer System Interface (SCSI) devices • System Console • Local Area Network (LAN) Console • LANs • Power Cord 8 Chapter 1 When ...
...server by means of specific connectors located on the rear bulkhead. NOTE For technical support please call your local support hotline or contact HP at the front of Servers - When lit, indicates that requires immediate operator action. 4. (Amber) Remote LED - Server External .... 5. (Green) Power LED - ccrr018 Fault Remote Power 1. (Green) RUN LED - Exterior connections to the server include ports for: • Small Computer System Interface (SCSI) devices • System Console • Local Area Network (LAN) Console • LANs • Power Cord 8 Chapter 1 When ...
Basic Cable Connections - hp rp2400 Series of Servers
Page 9
... connect an RJ45 LAN cable to the Secure Web Console PCI card installed in an I/O card slot on rp2400) at http://docs.hp.com. HP rp2400 Series of the external connections to the server. If the Secure Web Console PCI card is to the Ultra 2 SCSI bus ...100BASE-T Path: 0/0/0/0 10BASE-T LAN Console Path: 0/6/0 Path: 0/6/0 Pull-Out Tab ccrr008 Connect External Small Computer System Interface (SCSI) Devices Connect external SCSI devices to the single ended SCSI bus (labeled: Narrow Single-Ended SCSI Path: 0/0/2/0) on the system card or to be used as a System Console. Basic Cable ...
... connect an RJ45 LAN cable to the Secure Web Console PCI card installed in an I/O card slot on rp2400) at http://docs.hp.com. HP rp2400 Series of the external connections to the server. If the Secure Web Console PCI card is to the Ultra 2 SCSI bus ...100BASE-T Path: 0/0/0/0 10BASE-T LAN Console Path: 0/6/0 Path: 0/6/0 Pull-Out Tab ccrr008 Connect External Small Computer System Interface (SCSI) Devices Connect external SCSI devices to the single ended SCSI bus (labeled: Narrow Single-Ended SCSI Path: 0/0/2/0) on the system card or to be used as a System Console. Basic Cable ...
Basic Cable Connections - hp rp2400 Series of Servers
Page 11
Figure 1-4 Console Connection and Configuration To Console/UPS port at rear server A5191-63001 COMPUTER 25-Pin UPS 9-Pin REMOTE 9-Pin CONSOLE 9-Pin 9-Pin OR 9-Pin A5858-63001 CABLE 24542G CABLE 9-Pin cons_connect_config To optional built-in (PCI) Secure Web Console 25-Pin To Local VT-100 Console Chapter 1 11 Basic Cable Connections Console Connection and Configuration Console Connection and Configuration The following describes of the installation and configuration of Servers - HP rp2400 Series of the rp24xx server console.
Figure 1-4 Console Connection and Configuration To Console/UPS port at rear server A5191-63001 COMPUTER 25-Pin UPS 9-Pin REMOTE 9-Pin CONSOLE 9-Pin 9-Pin OR 9-Pin A5858-63001 CABLE 24542G CABLE 9-Pin cons_connect_config To optional built-in (PCI) Secure Web Console 25-Pin To Local VT-100 Console Chapter 1 11 Basic Cable Connections Console Connection and Configuration Console Connection and Configuration The following describes of the installation and configuration of Servers - HP rp2400 Series of the rp24xx server console.
Generic Site Preparation Guide, Fourth Edition
Page 3
...Synopsis...7 AC Electrical Distribution System 7 AC Power Quality Devices...7 UPS Recommendations...8 Power Consumption...8 Grounding Systems...8 Comprehensive Discussion...9 Computer Room Safety...9 Fire Protection...9 Fire Suppression...10 Lighting Requirements for Equipment Servicing 10 Cabinet Recommendations...10 Working Space for Server... Safety Grounding (LAHJ 12 Main Building Electrical Ground 12 Electrical Conduit Ground...13 Power Panel Ground...13 Computer Safety Ground...13 Dual Power Source Grounding 13 Cabinet Performance Grounding (High-Frequency Intercabinet Ground 13 Raised ...
...Synopsis...7 AC Electrical Distribution System 7 AC Power Quality Devices...7 UPS Recommendations...8 Power Consumption...8 Grounding Systems...8 Comprehensive Discussion...9 Computer Room Safety...9 Fire Protection...9 Fire Suppression...10 Lighting Requirements for Equipment Servicing 10 Cabinet Recommendations...10 Working Space for Server... Safety Grounding (LAHJ 12 Main Building Electrical Ground 12 Electrical Conduit Ground...13 Power Panel Ground...13 Computer Safety Ground...13 Dual Power Source Grounding 13 Cabinet Performance Grounding (High-Frequency Intercabinet Ground 13 Raised ...
Generic Site Preparation Guide, Fourth Edition
Page 7
... building or area might be installed in the middle of voltage tolerances. Although utility-fed AC power is in : • Controlled computer room • Controlled office • Uncontrolled office/home • Light industrial • Mobile/portable However, the implementation of these ...recommendations become loose over time and subject to loading problems. HP recommends using a higher input voltage to power source X0 is sourced from a receptacle to the stepdown transformer within 75 feet (23 ...
... building or area might be installed in the middle of voltage tolerances. Although utility-fed AC power is in : • Controlled computer room • Controlled office • Uncontrolled office/home • Light industrial • Mobile/portable However, the implementation of these ...recommendations become loose over time and subject to loading problems. HP recommends using a higher input voltage to power source X0 is sourced from a receptacle to the stepdown transformer within 75 feet (23 ...
Generic Site Preparation Guide, Fourth Edition
Page 8
... electrical infrastructure. NOTE: Set cooling for the maximum-rated power output of sourcing a cabinet UPS from a room UPS as infrastructure grows. HP computer hardware has been tested only on your local electrical code, the electrical infrastructure should have UPS sourcing and dedicated breakers. • A few... UPS. Failure to properly ground the equipment or the floor can result in the middle of the infrastructure. This grounding is on computer equipment list the ratings for a nonlinear load. Indeed, this can lead to the AC distribution point. It is in increased costs...
... electrical infrastructure. NOTE: Set cooling for the maximum-rated power output of sourcing a cabinet UPS from a room UPS as infrastructure grows. HP computer hardware has been tested only on your local electrical code, the electrical infrastructure should have UPS sourcing and dedicated breakers. • A few... UPS. Failure to properly ground the equipment or the floor can result in the middle of the infrastructure. This grounding is on computer equipment list the ratings for a nonlinear load. Indeed, this can lead to the AC distribution point. It is in increased costs...
Generic Site Preparation Guide, Fourth Edition
Page 9
...in this task must have a thorough knowledge of appropriate electrical codes and the limitations of the power systems for computer rooms. Most computer rooms are equipped with the following fire protection devices: • Smoke detectors • Fire and temperature alarms ...the Protective Earth (PE) conductor be a paramount consideration when performing the following recommendations. Federal and local safety codes govern computer installations. For regions and areas outside North America, local electrical codes take precedence over North American electrical codes. Comprehensive Discussion...
...in this task must have a thorough knowledge of appropriate electrical codes and the limitations of the power systems for computer rooms. Most computer rooms are equipped with the following fire protection devices: • Smoke detectors • Fire and temperature alarms ...the Protective Earth (PE) conductor be a paramount consideration when performing the following recommendations. Federal and local safety codes govern computer installations. For regions and areas outside North America, local electrical codes take precedence over North American electrical codes. Comprehensive Discussion...