Serial Attached SCSI storage technology, 2nd Edition
Page 1
Serial Attached SCSI storage technology 2nd Edition Abstract...2 Transition from parallel to serial SCSI protocol 2 SAS terminology...2 SAS technology ...3 SAS devices ...3 Initiators ...4 Expanders ...4 Targets ...4 Differential signaling ...5 SAS protocol evolution ...6 SAS-1 ...6 SAS-2 ...6 SAS-2.1 ...6 Active cables ...6 Storage power management...7 SAS/SATA interoperability ...8 Cabling and connectors ...9 Mini SAS 4x cable connectors and ...
Serial Attached SCSI storage technology 2nd Edition Abstract...2 Transition from parallel to serial SCSI protocol 2 SAS terminology...2 SAS technology ...3 SAS devices ...3 Initiators ...4 Expanders ...4 Targets ...4 Differential signaling ...5 SAS protocol evolution ...6 SAS-1 ...6 SAS-2 ...6 SAS-2.1 ...6 Active cables ...6 Storage power management...7 SAS/SATA interoperability ...8 Cabling and connectors ...9 Mini SAS 4x cable connectors and ...
Serial Attached SCSI storage technology, 2nd Edition
Page 2
... SAS technology to aid in understanding the concepts described in 1981 to provide a common interface that functions as a switch to attach one or more initiators to one or more targets A device containing SSP, STP, and/or SMP initiator ports in a SAS domain 2 Abstract This technology brief ... SCSI could be used across all peripheral platforms and system applications, such as Redundant Array of Independent Disks (RAID) storage. In 2001, HP (Compaq), IBM, LSI Logic, Maxtor, and Seagate founded the Serial Attached SCSI Working Group to come. Each generation doubled the bandwidth of...
... SAS technology to aid in understanding the concepts described in 1981 to provide a common interface that functions as a switch to attach one or more initiators to one or more targets A device containing SSP, STP, and/or SMP initiator ports in a SAS domain 2 Abstract This technology brief ... SCSI could be used across all peripheral platforms and system applications, such as Redundant Array of Independent Disks (RAID) storage. In 2001, HP (Compaq), IBM, LSI Logic, Maxtor, and Seagate founded the Serial Attached SCSI Working Group to come. Each generation doubled the bandwidth of...
Serial Attached SCSI storage technology, 2nd Edition
Page 3
...zone that all have the same access permission A group of the OSI model. SAS devices There are low-cost, high-speed switches that transmits information between phys SAS technology SAS is attached to one bit at a time). An initiator device is not able to...address Serial ATA Tunneling Protocol (STP) Serial Management Protocol (SMP) Serial SCSI Protocol (SSP) Service delivery subsystem Subtractive routing Table routing Target Training Virtual phy Wide link Wide port Zone group Zoned portion of a service delivery subsystem (ZPSDS) International Organization for Standardization/International ...
...zone that all have the same access permission A group of the OSI model. SAS devices There are low-cost, high-speed switches that transmits information between phys SAS technology SAS is attached to one bit at a time). An initiator device is not able to...address Serial ATA Tunneling Protocol (STP) Serial Management Protocol (SMP) Serial SCSI Protocol (SSP) Service delivery subsystem Subtractive routing Table routing Target Training Virtual phy Wide link Wide port Zone group Zoned portion of a service delivery subsystem (ZPSDS) International Organization for Standardization/International ...
Serial Attached SCSI storage technology, 2nd Edition
Page 4
... the expanders' routing tables. 4 SAS domain (Figure 1). Each initiator port can reside in a domain Initiators SAS initiators have two narrow ports. Targets SAS hard drives (enterprise-class and midline devices) have multiple ports for fail-over redundancy and load balancing. SAS hard drives leverage a common electrical... physical connection interface with SATA hard drives. Expanders use three routing methods-direct, table, and subtractive. The number of the target. An expander uses table routing to forward commands and data to another port based on the SAS address of initiators and...
... the expanders' routing tables. 4 SAS domain (Figure 1). Each initiator port can reside in a domain Initiators SAS initiators have two narrow ports. Targets SAS hard drives (enterprise-class and midline devices) have multiple ports for fail-over redundancy and load balancing. SAS hard drives leverage a common electrical... physical connection interface with SATA hard drives. Expanders use three routing methods-direct, table, and subtractive. The number of the target. An expander uses table routing to forward commands and data to another port based on the SAS address of initiators and...
Serial Attached SCSI storage technology, 2nd Edition
Page 6
...expanders by reducing near-end crosstalk (NEXT). SAS-2 also enables zoning for the dielectric and conductor losses. Each SAS device (initiator, target, or expander) may be connected together to form an edge expander device set, allowing the set to address up to -noise ...a more SAS communication speeds. Active circuitry includes built-in one or more extensive routing table. An edge expander attaches directly to targets, or to another edge expander, which the linked devices exchange predefined signals to compensate for enhanced resource deployment flexibility, security, and ...
...expanders by reducing near-end crosstalk (NEXT). SAS-2 also enables zoning for the dielectric and conductor losses. Each SAS device (initiator, target, or expander) may be connected together to form an edge expander device set, allowing the set to address up to -noise ...a more SAS communication speeds. Active circuitry includes built-in one or more extensive routing table. An edge expander attaches directly to targets, or to another edge expander, which the linked devices exchange predefined signals to compensate for enhanced resource deployment flexibility, security, and ...
Serial Attached SCSI storage technology, 2nd Edition
Page 14
... compatible. Figure 12 shows a multi-node cluster application using an ASIC (application-specific integrated circuit) embedded on the motherboard. Zoning The number of devices (initiators, targets, expanders, and/or virtual devices) allowed in the domain as a zoned portion of the expander routing tables.
... compatible. Figure 12 shows a multi-node cluster application using an ASIC (application-specific integrated circuit) embedded on the motherboard. Zoning The number of devices (initiators, targets, expanders, and/or virtual devices) allowed in the domain as a zoned portion of the expander routing tables.
Using InfiniBand for a Scalable Compute Infrastructure
Page 5
...and, depending on type, can communicate directly with another HCA, with a target channel adapter, or with an HCA or an InfiniBand switch. An HCA can be located within the fabric, and provides switching and configuration information to -point connection or multiple connections through a variety of...simple as core capabilities and offers greater adaptability through one or more switches. While the majority of existing InfiniBand clusters operate on a node or switch within the fabric for Microsoft® Windows®, HP-UX, Solaris, and other nodes in an expansion slot or ...
...and, depending on type, can communicate directly with another HCA, with a target channel adapter, or with an HCA or an InfiniBand switch. An HCA can be located within the fabric, and provides switching and configuration information to -point connection or multiple connections through a variety of...simple as core capabilities and offers greater adaptability through one or more switches. While the majority of existing InfiniBand clusters operate on a node or switch within the fabric for Microsoft® Windows®, HP-UX, Solaris, and other nodes in an expansion slot or ...
Using InfiniBand for a Scalable Compute Infrastructure
Page 9
The adoption of 4X DDR products is widespread, and deployment of QDR systems is reserved for fabric management and the other lanes for packet transport. one lane is expected to increase. The InfiniBand architecture defines a virtual lane mapping algorithm to ... were divided into a set of virtual lanes, similar to communicate autonomously. InfiniBand connectors CX4 QSFP Fiber optic cable with CX4 connectors generally offers the greatest distance capability. InfiniBand virtual lane operation Sources Targets 1 The IBTA specification defines a minimum of two and a maximum of ...
The adoption of 4X DDR products is widespread, and deployment of QDR systems is reserved for fabric management and the other lanes for packet transport. one lane is expected to increase. The InfiniBand architecture defines a virtual lane mapping algorithm to ... were divided into a set of virtual lanes, similar to communicate autonomously. InfiniBand connectors CX4 QSFP Fiber optic cable with CX4 connectors generally offers the greatest distance capability. InfiniBand virtual lane operation Sources Targets 1 The IBTA specification defines a minimum of two and a maximum of ...
Using InfiniBand for a Scalable Compute Infrastructure
Page 13
...target level. InfiniBand is further strengthened by an application written to a fabric. Flow control support is native to the HCA design, and the latency time for InfiniBand data transfers is a core capability of InfiniBand architecture. Parallel compute applications that for 10Gb Ethernet. HP is committed to support both InfiniBand... of message passing between servers connected to the HP-MPI protocol. HP BladeSystem c-Class clusters and similar rack-mounted clusters support IB QDR and DDR HCAs and switches. Conclusion InfiniBand offers an industry standard, high-bandwidth, low-latency...
...target level. InfiniBand is further strengthened by an application written to a fabric. Flow control support is native to the HCA design, and the latency time for InfiniBand data transfers is a core capability of InfiniBand architecture. Parallel compute applications that for 10Gb Ethernet. HP is committed to support both InfiniBand... of message passing between servers connected to the HP-MPI protocol. HP BladeSystem c-Class clusters and similar rack-mounted clusters support IB QDR and DDR HCAs and switches. Conclusion InfiniBand offers an industry standard, high-bandwidth, low-latency...
Using InfiniBand for a Scalable Compute Infrastructure
Page 14
... Single Data Rate: for InfiniBand, standard clock rate of 2.5 Gbps Subnet Manager: management software for InfiniBand network SCSI RDMA Protocol: data movement protocol Target Channel Adapter: hardware interface ... InfiniBand: interconnect technology for distributed computing/storage infrastructure IP Internet Protocol: standard of data communication over a packet-switched network IPoIP Internet Protocol over InfiniBand:...Programming Interface: software routine or object written in support of a language DDR Double Data Rate: for InfiniBand, clock rate of 10 Gbps (2.5 Gbps x 4) Quad Small ...
... Single Data Rate: for InfiniBand, standard clock rate of 2.5 Gbps Subnet Manager: management software for InfiniBand network SCSI RDMA Protocol: data movement protocol Target Channel Adapter: hardware interface ... InfiniBand: interconnect technology for distributed computing/storage infrastructure IP Internet Protocol: standard of data communication over a packet-switched network IPoIP Internet Protocol over InfiniBand:...Programming Interface: software routine or object written in support of a language DDR Double Data Rate: for InfiniBand, clock rate of 10 Gbps (2.5 Gbps x 4) Quad Small ...