Aqua Solar
Page 1
Aqua Solar Electronic Solar Control Center Operation and Installation Manual AQ-SOL-LV AQ-SOL-LV-TC AQ-SOL-LV-SP www.haywardnet.com Temperature/Resistance /Voltage All Hayward controls use a 10K thermistor sensors. All voltage measurements (DC) must be made with the sensor connected to the control and ... temperature reading should be accurate to the chart below for the resistance at 25ºC/77ºF. Elizabeth, NJ 07207 092008F RevG Copyright © 2010 Hayward Inc. Refer to ± 2%. °F Ohms Volts °F Ohms Volts °F Ohms Volts °F Ohms Volts 1 82,719 4.46 41 ...
Aqua Solar Electronic Solar Control Center Operation and Installation Manual AQ-SOL-LV AQ-SOL-LV-TC AQ-SOL-LV-SP www.haywardnet.com Temperature/Resistance /Voltage All Hayward controls use a 10K thermistor sensors. All voltage measurements (DC) must be made with the sensor connected to the control and ... temperature reading should be accurate to the chart below for the resistance at 25ºC/77ºF. Elizabeth, NJ 07207 092008F RevG Copyright © 2010 Hayward Inc. Refer to ± 2%. °F Ohms Volts °F Ohms Volts °F Ohms Volts °F Ohms Volts 1 82,719 4.46 41 ...
Aqua Solar
Page 3
..., you don't need to disconnect the sensor). Alternatively, you don't need to disconnect the sensor). "Aux Sensor" LED flashing "Err" on the solar temperature display: On continuously indicates a probable open circuit in the "POOL" sensor or wiring. Flashing indicates a probable short circuit in the "AUX" ...If the sensor and wiring are both good, then the main circuit PCB may have a problem. When the Aux sensor is shorted, the Aqua Solar will still operate properly. If the sensor and wiring are both good, then the main circuit PCB may have a problem. 7. In either...
..., you don't need to disconnect the sensor). Alternatively, you don't need to disconnect the sensor). "Aux Sensor" LED flashing "Err" on the solar temperature display: On continuously indicates a probable open circuit in the "POOL" sensor or wiring. Flashing indicates a probable short circuit in the "AUX" ...If the sensor and wiring are both good, then the main circuit PCB may have a problem. When the Aux sensor is shorted, the Aqua Solar will still operate properly. If the sensor and wiring are both good, then the main circuit PCB may have a problem. 7. In either...
Aqua Solar
Page 4
...sensor is not connected OR a freeze snap switch is open . order relays separately (part no. Check to see if the Aqua Solar power is connected to giving incorrect readings, check the sensors using the temperature/resistance/voltage chart on ) due to cool the... the sensors using the temperature/ resistance/voltage chart on , -3ºF off time to resume normal operation. 5. Aqua Solar Digital Solar Control System The Aqua Solar Digital Solar Control System is a differential temperature control for pools that overheat in hot climates) and recirculate freeze protection functions can...
...sensor is not connected OR a freeze snap switch is open . order relays separately (part no. Check to see if the Aqua Solar power is connected to giving incorrect readings, check the sensors using the temperature/resistance/voltage chart on ) due to cool the... the sensors using the temperature/ resistance/voltage chart on , -3ºF off time to resume normal operation. 5. Aqua Solar Digital Solar Control System The Aqua Solar Digital Solar Control System is a differential temperature control for pools that overheat in hot climates) and recirculate freeze protection functions can...
Aqua Solar
Page 5
... a freeze condition at the main circuit breaker. When recirculate freeze protection is enabled, the Aqua Solar will operate automatically based on and off time using the series of small slide "trippers" located around the outside of the timeclock. Hayward highly recommends that one or more "freeze snap switches" (model GC-3) be placed in...
... a freeze condition at the main circuit breaker. When recirculate freeze protection is enabled, the Aqua Solar will operate automatically based on and off time using the series of small slide "trippers" located around the outside of the timeclock. Hayward highly recommends that one or more "freeze snap switches" (model GC-3) be placed in...
Aqua Solar
Page 6
...and on page 7. Be careful to cycle through the various displays. "1" (up) - Sweep Interlock: The pool sweep is enabled, the Aqua Solar will turn the pump and solar valve on the built-in timeclock in parallel with the AUX sensor (short circuit, only when used ): 3rd button push will show "...on when there is active. AQ-SOL-LV: This relay should be wired in addition to the "trippers" set on during freezing conditions. The Aqua Solar will also turn the filter pump on . MANUAL CONTROL The manual control can override the timer and is active. timer controls pump "0" (down...
...and on page 7. Be careful to cycle through the various displays. "1" (up) - Sweep Interlock: The pool sweep is enabled, the Aqua Solar will turn the pump and solar valve on the built-in timeclock in parallel with the AUX sensor (short circuit, only when used ): 3rd button push will show "...on when there is active. AQ-SOL-LV: This relay should be wired in addition to the "trippers" set on during freezing conditions. The Aqua Solar will also turn the filter pump on . MANUAL CONTROL The manual control can override the timer and is active. timer controls pump "0" (down...
Aqua Solar
Page 7
... pump wiring. 2) Most codes require that each pump be on a separate circuit. 3) Aqua Solar will ensure sweep pump runs only when filter pump is running. 4) Sweep pump will turn off power at circuit breaker before wiring. For Hayward, Jandy, and Compool valve actuators (with the knockouts facing downward. Mount the enclosure vertically... or 240VAC per the diagram below. AQ-SOL-LV-TC with filter pump & pool sweep relays 120/240 VAC Pool Sweep Timer 240 VAC Aqua Solar (AQ-SOL-LV-TC) Booster Pump Pool Sweep Filter Pump 240 VAC Ground Sweep Pump Filter Pump NOTES: 1) Do not use the...
... pump wiring. 2) Most codes require that each pump be on a separate circuit. 3) Aqua Solar will ensure sweep pump runs only when filter pump is running. 4) Sweep pump will turn off power at circuit breaker before wiring. For Hayward, Jandy, and Compool valve actuators (with the knockouts facing downward. Mount the enclosure vertically... or 240VAC per the diagram below. AQ-SOL-LV-TC with filter pump & pool sweep relays 120/240 VAC Pool Sweep Timer 240 VAC Aqua Solar (AQ-SOL-LV-TC) Booster Pump Pool Sweep Filter Pump 240 VAC Ground Sweep Pump Filter Pump NOTES: 1) Do not use the...
Aqua Solar
Page 8
... the PC sensor until the O-ring makes an adequate seal. Ground the shields to cross phases on page 9). Order additional relays separately (Hayward p/n AQ-RELAY). Position the hose clamp over the sensor and gently tighten until the O-ring collar sits flush on . Sensor wiring run...relays are industry standard and are also being used , drill a 3/8" (10mm) hole in direct sunlight, away from the weather. If the Aqua Solar is required (see description of a 240VAC circuit. Additionally, the underside of the sensing element may be connected to the LOAD side of two high...
... the PC sensor until the O-ring makes an adequate seal. Ground the shields to cross phases on page 9). Order additional relays separately (Hayward p/n AQ-RELAY). Position the hose clamp over the sensor and gently tighten until the O-ring collar sits flush on . Sensor wiring run...relays are industry standard and are also being used , drill a 3/8" (10mm) hole in direct sunlight, away from the weather. If the Aqua Solar is required (see description of a 240VAC circuit. Additionally, the underside of the sensing element may be connected to the LOAD side of two high...