SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL HSU-05LEA03 HSU-07LEA03 HSU-09LEA03 HSU-09LEA03G HSU-09LEA03U HSU-12LEA03 HSU-12HEA03 HSU-12LEA03G HSU-12LEA03U HSU-18LEA03 HSU-18HEA03 HSU-18LEA03G HSU-18LEA03U HSU-22LEA03 HSU-22HEA03 HSU-22LEA03G HSU-22LEA03U HSU-24LEA03 Please read this operation manual before using the air conditioner. 0010517097
SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL HSU-05LEA03 HSU-07LEA03 HSU-09LEA03 HSU-09LEA03G HSU-09LEA03U HSU-12LEA03 HSU-12HEA03 HSU-12LEA03G HSU-12LEA03U HSU-18LEA03 HSU-18HEA03 HSU-18LEA03G HSU-18LEA03U HSU-22LEA03 HSU-22HEA03 HSU-22LEA03G HSU-22LEA03U HSU-24LEA03 Please read this operation manual before using the air conditioner. 0010517097
User Manual
Page 2
... repairs may result in strict compliance with specifications. The valuable materials The manufacturer does not accept respon- Use of the air conditioner is to be carried out by qualified electricians. disposal service. The User's Guide contains very impor- tant observations relating to... nearest to your people, don't install unit by yourself. Cautions Disposal of the old air conditioner Safety Instructions and Warnings Before disposing an old air conditioner that carry refrigerant by piercing Consult your local authorities for to non-observation of the following...
... repairs may result in strict compliance with specifications. The valuable materials The manufacturer does not accept respon- Use of the air conditioner is to be carried out by qualified electricians. disposal service. The User's Guide contains very impor- tant observations relating to... nearest to your people, don't install unit by yourself. Cautions Disposal of the old air conditioner Safety Instructions and Warnings Before disposing an old air conditioner that carry refrigerant by piercing Consult your local authorities for to non-observation of the following...
User Manual
Page 3
...seconds later, cutting off the power. Cautions Do not obstruct or cover the ventilation 7. The machine is adaptive in line with the type of the air conditoner.Do not put fingers by the manufacturer or its service agent or a similar qualified person. 3. If the fuse of indoor unit on the ...should be to ensure that they do not play with the applience. Young children should be supervised Do not allow children to play with the air conditioner.In no case should be replaced by young children or infirm persons or any other things into the power supply cord. The appliance is ...
...seconds later, cutting off the power. Cautions Do not obstruct or cover the ventilation 7. The machine is adaptive in line with the type of the air conditoner.Do not put fingers by the manufacturer or its service agent or a similar qualified person. 3. If the fuse of indoor unit on the ...should be to ensure that they do not play with the applience. Young children should be supervised Do not allow children to play with the air conditioner.In no case should be replaced by young children or infirm persons or any other things into the power supply cord. The appliance is ...
User Manual
Page 5
... cable. inflammable gas leakage around the unit. Check proper installation of or oil steam. lnstallation in the following Safety Instructions carefully prior to install the air conditioner by yourself because improper works may cause accidents. Cautions Safety Instruction Please read the following place. Compliance to the instructions are classified into two levels...
... cable. inflammable gas leakage around the unit. Check proper installation of or oil steam. lnstallation in the following Safety Instructions carefully prior to install the air conditioner by yourself because improper works may cause accidents. Cautions Safety Instruction Please read the following place. Compliance to the instructions are classified into two levels...
User Manual
Page 9
.... Put on the indoor unit. If the remote controller can't run normally or doesn't work at all, use in power failure resume mode, if the air conditioner is supplied again. Power failure resume(please set and apply as illustrated. 2 R-03 batteries, resetting key (cylinder) Remove the battery cover: Slightly press " " and push...
.... Put on the indoor unit. If the remote controller can't run normally or doesn't work at all, use in power failure resume mode, if the air conditioner is supplied again. Power failure resume(please set and apply as illustrated. 2 R-03 batteries, resetting key (cylinder) Remove the battery cover: Slightly press " " and push...
User Manual
Page 10
... Operation Auto Operation (1) Unit start with those displayed in each press, fan speed changes as follows: Remote controller: AUTO LO MED HI Air conditioner is running under displayed fan speed. No reelecting is needed.(TIMER ON/OFF ǃSLEEPǃSWING needs reelecting) Cautions: On cooling only... unit, heating mode is not available, Note: The above information is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature. (4)Unit stop Press ON/OFF button, the unit stops. When FAN is the After...
... Operation Auto Operation (1) Unit start with those displayed in each press, fan speed changes as follows: Remote controller: AUTO LO MED HI Air conditioner is running under displayed fan speed. No reelecting is needed.(TIMER ON/OFF ǃSLEEPǃSWING needs reelecting) Cautions: On cooling only... unit, heating mode is not available, Note: The above information is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature. (4)Unit stop Press ON/OFF button, the unit stops. When FAN is the After...
User Manual
Page 11
... as follows: Remote controller: ON/OFF TEMP 5 13 MODE 2 FAN 4 SWING 3 SET TIMER CLOCK SLEEP HEALTH LOCK RESET AUTO LO MED HI Air conditioner is set to AUTO, the air conditioner automatically adjusts the fan speed according to reach the temp. setting decreases 1oC Unit will run in previous status. For each operation status...
... as follows: Remote controller: ON/OFF TEMP 5 13 MODE 2 FAN 4 SWING 3 SET TIMER CLOCK SLEEP HEALTH LOCK RESET AUTO LO MED HI Air conditioner is set to AUTO, the air conditioner automatically adjusts the fan speed according to reach the temp. setting decreases 1oC Unit will run in previous status. For each operation status...
User Manual
Page 13
setting increases 1oC Every time the button is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature. (5) Unit stop Press ON/OFF button, the unit stops. Stop display at your desired mode. (3) Select ... follows: Remote controller: ON/OFF TEMP 5 13 MODE 2 FAN 4 SWING 3 SET TIMER CLOCK SLEEP HEALTH LOCK RESET AUTO LO MED HI IN HEAT mode, warm air will start Press ON/OFF button, unit starts. setting Press TEMP button. setting on display. (Not Timer setting) (2) Select operation mode Press MODE button. setting...
setting increases 1oC Every time the button is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature. (5) Unit stop Press ON/OFF button, the unit stops. Stop display at your desired mode. (3) Select ... follows: Remote controller: ON/OFF TEMP 5 13 MODE 2 FAN 4 SWING 3 SET TIMER CLOCK SLEEP HEALTH LOCK RESET AUTO LO MED HI IN HEAT mode, warm air will start Press ON/OFF button, unit starts. setting Press TEMP button. setting on display. (Not Timer setting) (2) Select operation mode Press MODE button. setting...
User Manual
Page 15
...horizontal flap will be much more helpful for a long time in COOL mode, adjusting air flow horizontally will swing according to the above positions 3.Left and right air flow adjustment(manual) Move the vertical blade by hand. It is high,condensate water ...Air Flow Direction Adjustment 1.Status display of air sending Horizontal flap Pos.1 ( Cool/Dry standard position) Pos.2 ( Upward swing ) Pos.3 ( Downward swing ) Pos.4 ( Auto swing ) Remote controller Blank 2.Up and down air flow direction(Use remote controller) For each press of SWING button, air flow direction on air conditioner...
...horizontal flap will be much more helpful for a long time in COOL mode, adjusting air flow horizontally will swing according to the above positions 3.Left and right air flow adjustment(manual) Move the vertical blade by hand. It is high,condensate water ...Air Flow Direction Adjustment 1.Status display of air sending Horizontal flap Pos.1 ( Cool/Dry standard position) Pos.2 ( Upward swing ) Pos.3 ( Downward swing ) Pos.4 ( Auto swing ) Remote controller Blank 2.Up and down air flow direction(Use remote controller) For each press of SWING button, air flow direction on air conditioner...
User Manual
Page 17
Operation HEALTH Operation 1.Unit start Press the ON/OFF switch 2.Health anion function Press the " HEALTH"once, " " is displayed, now the air conditioner is operating the healthy function. 3.To Cancel HEALTH Model Press the " HEALTH"again, then the healthy function stops. ON ON/OFF 1 MODE TEMP ... SLEEP HEALTH 3 LOCK 2 RESET Brief introduction to health anion function The anion generator in the air conditioner can generate a lot of anion effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean ...
Operation HEALTH Operation 1.Unit start Press the ON/OFF switch 2.Health anion function Press the " HEALTH"once, " " is displayed, now the air conditioner is operating the healthy function. 3.To Cancel HEALTH Model Press the " HEALTH"again, then the healthy function stops. ON ON/OFF 1 MODE TEMP ... SLEEP HEALTH 3 LOCK 2 RESET Brief introduction to health anion function The anion generator in the air conditioner can generate a lot of anion effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean ...
User Manual
Page 21
OFF 20 Maintenance For Smart Use of The Air Conditioner Setting of proper room Do not block the air inlet temperature or outlet Proper temperature Close doors and windows Use the timer effectively during operation During cooling operation prevent the penetration of direct sunlight with curtain or blind If the unit is not to be used Use the louvers effectively for a long time, turn off the power supply main switch.
OFF 20 Maintenance For Smart Use of The Air Conditioner Setting of proper room Do not block the air inlet temperature or outlet Proper temperature Close doors and windows Use the timer effectively during operation During cooling operation prevent the penetration of direct sunlight with curtain or blind If the unit is not to be used Use the louvers effectively for a long time, turn off the power supply main switch.
User Manual
Page 22
...to the front.Make sure that the filter is released from the stopper, and remove the filter downward. Remove the filter. Wipe the air conditioner by pulling it is completely fixed behind the stopper.If the right and left filters are not attached correctly, that may cause defects.... Attach the filter. Once every two weeks 21 Maintenance For Smart Use of The Air Conditioner WARNING Before maintenance,be sure to turn off the detergent completely. Close the inlet grille. Remote Controller Indoor Body Do not use the...
...to the front.Make sure that the filter is released from the stopper, and remove the filter downward. Remove the filter. Wipe the air conditioner by pulling it is completely fixed behind the stopper.If the right and left filters are not attached correctly, that may cause defects.... Attach the filter. Once every two weeks 21 Maintenance For Smart Use of The Air Conditioner WARNING Before maintenance,be sure to turn off the detergent completely. Close the inlet grille. Remote Controller Indoor Body Do not use the...
User Manual
Page 24
... system does not restart immediately. Are there any direct sunlight through the window during cooling operation? This is due to protect the air conditioner. Is fuse blownout? Are there some doors or windows left open? Trouble shooting Before asking for 3 minutes to the sudden cooling of... air conditioner -7oC~43oC. 23 During unit operation or at LOW speed regardless of furniture, paint, cigarettes. Normally it won't restart immediately until 3 ...
... system does not restart immediately. Are there any direct sunlight through the window during cooling operation? This is due to protect the air conditioner. Is fuse blownout? Are there some doors or windows left open? Trouble shooting Before asking for 3 minutes to the sudden cooling of... air conditioner -7oC~43oC. 23 During unit operation or at LOW speed regardless of furniture, paint, cigarettes. Normally it won't restart immediately until 3 ...