User Manual
Page 7
...inflammable gases because the inflammable gases near to air-conditioner may cause shock. CAUTION ! Earthing Use discharge pipe correctly to install the air-conditioner. Air-conditioner should not be installed in the following conditions. WARNING ! Air-conditioner can't be connected to the machine emitting electric...accessible place. Earthing wire should not be created. It easily cause electrical shock without circuit breaker. [Location] Air-conditioner should be equipped with acid, alkali vapuor. Incorrect pipe use may cause water leaking, shock and fire ...
...inflammable gases because the inflammable gases near to air-conditioner may cause shock. CAUTION ! Earthing Use discharge pipe correctly to install the air-conditioner. Air-conditioner should not be installed in the following conditions. WARNING ! Air-conditioner can't be connected to the machine emitting electric...accessible place. Earthing wire should not be created. It easily cause electrical shock without circuit breaker. [Location] Air-conditioner should be equipped with acid, alkali vapuor. Incorrect pipe use may cause water leaking, shock and fire ...
User Manual
Page 12
Clean Notice Do not use soft brush and neutral detergent. (C) Throw the water off, then put it in a dusty environment, the air filter should be burnt. Do not dry the unit on fire, the filter may cause trouble. Open and remove (B) When the dust is too much, ... clean to remove dust. Open 1. Use cleaner or water to clean to remove dust. (A) Use cleaner to avoid discoloration or deformation. When the air conditioner is reversed.) 2.Dismantle the air filter Pull the two side handles at the same time, slowly draw them out. (when closing it, the procedure is used in the...
Clean Notice Do not use soft brush and neutral detergent. (C) Throw the water off, then put it in a dusty environment, the air filter should be burnt. Do not dry the unit on fire, the filter may cause trouble. Open and remove (B) When the dust is too much, ... clean to remove dust. Open 1. Use cleaner or water to clean to remove dust. (A) Use cleaner to avoid discoloration or deformation. When the air conditioner is reversed.) 2.Dismantle the air filter Pull the two side handles at the same time, slowly draw them out. (when closing it, the procedure is used in the...
User Manual
Page 14
.... Stop operation and turn off the power supply switch .Electric power is consumed even the air conditioner is not dirty. The inner part of both indoor and outdoor unit to install the air filter, ensure that the air filter is in machine damages or cause malfunciton due th dust inside of the unit well... unit To prevent compressor when start in HEAT mode, please cut in room. 13 Pre-season Care See that there is no obstacles blocking the air inlet and air outlet of indoor unit must be cleaned. Maintenance Seasonal Reserve Post-season Care Operate the unit with dustcoat.
.... Stop operation and turn off the power supply switch .Electric power is consumed even the air conditioner is not dirty. The inner part of both indoor and outdoor unit to install the air filter, ensure that the air filter is in machine damages or cause malfunciton due th dust inside of the unit well... unit To prevent compressor when start in HEAT mode, please cut in room. 13 Pre-season Care See that there is no obstacles blocking the air inlet and air outlet of indoor unit must be cleaned. Maintenance Seasonal Reserve Post-season Care Operate the unit with dustcoat.
User Manual
Page 15
...be restarted soon after it will soon back to the cooling mode. To prevent frost from the indoor unit sometimes smells. The air conditioner cannot be seen blown out of the system, therefore,it cannot be restarted for three minutes 14 Cracking sound is the flowing... sound of indoor unit. It is heard It smells. Automatically switch into the FAN mode,but it stops. Air conditioner does not start? During operation, white fog comes out of the refrigerant , not a malfunction. Trouble Shooting The followings are not malfuncition...
...be restarted soon after it will soon back to the cooling mode. To prevent frost from the indoor unit sometimes smells. The air conditioner cannot be seen blown out of the system, therefore,it cannot be restarted for three minutes 14 Cracking sound is the flowing... sound of indoor unit. It is heard It smells. Automatically switch into the FAN mode,but it stops. Air conditioner does not start? During operation, white fog comes out of the refrigerant , not a malfunction. Trouble Shooting The followings are not malfuncition...
User Manual
Page 16
This happens when the frost accumulated on ? Please check the following things about your air conditioner before making a service call. ON OFF Power supply switch is stopped. In DRY mode, when room temperature becomes 2 C higher than temperature setting, unit rill run...generated from the outdoor unit during drying. Unit fails to turn off the power supply switch immediately and contact the sales dealer. 14 Trouble Shooting Air does not blow or the fan speed cannot be changed during heating. Is the earth leakage breaker in ON position. Defrosting operation During heating,...
This happens when the frost accumulated on ? Please check the following things about your air conditioner before making a service call. ON OFF Power supply switch is stopped. In DRY mode, when room temperature becomes 2 C higher than temperature setting, unit rill run...generated from the outdoor unit during drying. Unit fails to turn off the power supply switch immediately and contact the sales dealer. 14 Trouble Shooting Air does not blow or the fan speed cannot be changed during heating. Is the earth leakage breaker in ON position. Defrosting operation During heating,...
User Manual
Page 17
...that is audible. 15 When Trouble Happens Insufficient cooling or heating The operation controller adjusted as required Air filter too dirty ? Cooled air blown out ( when heating) When the air conditioner does not operate properly after you have checked the above-mentioned items or when following phenomenon is observed...,stop the operation of the air conditioner and contact your sales dealer. 1)The fuse or breaker often shuts down. 2)Water drops off during cooling or drying operation....
...that is audible. 15 When Trouble Happens Insufficient cooling or heating The operation controller adjusted as required Air filter too dirty ? Cooled air blown out ( when heating) When the air conditioner does not operate properly after you have checked the above-mentioned items or when following phenomenon is observed...,stop the operation of the air conditioner and contact your sales dealer. 1)The fuse or breaker often shuts down. 2)Water drops off during cooling or drying operation....