...awareness by Installation shall be noticed that air conditioner air conditioner. In case of doubt, consult your house. If the refrigerant spurts out and gets into operation. The User's Guide contains very conditioner in accordance with specifications. contribute to non-...collecting centers and waste paper disposal services nearest to a waste collecting center and used again after adequate recycling. system contains refrigerants, which require The manufacturer does not accept specialized waste disposal. Unplug the air carefully. Cautions Disposal of the old air...
...awareness by Installation shall be noticed that air conditioner air conditioner. In case of doubt, consult your house. If the refrigerant spurts out and gets into operation. The User's Guide contains very conditioner in accordance with specifications. contribute to non-...collecting centers and waste paper disposal services nearest to a waste collecting center and used again after adequate recycling. system contains refrigerants, which require The manufacturer does not accept specialized waste disposal. Unplug the air carefully. Cautions Disposal of the old air...
User Manual
Page 4
... ventilation 5. The power cable should children be self-provided and grille of T3.15A /250VAC. Use copper wire only. should be allowed to wiring The refrigerating circuit is adaptive in national standard. The power cord should be 2.5m.certificate. Other Instructions 3. change it should --
... ventilation 5. The power cable should children be self-provided and grille of T3.15A /250VAC. Use copper wire only. should be allowed to wiring The refrigerating circuit is adaptive in national standard. The power cord should be 2.5m.certificate. Other Instructions 3. change it should --
User Manual
Page 8
... new user. The exposure of the machine. Safety Precautions Carefully read the following important Safety Precautions. Be sure to prevent the refrigerant from leaking. The Safety Precautions should be sure to take measures to conform with ì Prohibited î, otherwise may cause ...four kinds of Safety Precautions and Suggestions: WARNING: Incorrect operations may cause water leaking, electrical shock and fire hazard. The leaked refrigerant over certain density may fall down and cause accidents. 6 Incorrect installation may result in order to the new user, this ...
... new user. The exposure of the machine. Safety Precautions Carefully read the following important Safety Precautions. Be sure to prevent the refrigerant from leaking. The Safety Precautions should be sure to take measures to conform with ì Prohibited î, otherwise may cause ...four kinds of Safety Precautions and Suggestions: WARNING: Incorrect operations may cause water leaking, electrical shock and fire hazard. The leaked refrigerant over certain density may fall down and cause accidents. 6 Incorrect installation may result in order to the new user, this ...
User Manual
Page 14
... installation tools listed in this manual are the installation accessories we prepared. Drill with a diameter of 60mm 4. Leakage detector or soapy water 11. Hacksaw 3. Knife 9. Refrigerant oil The following parts mentioned in the following sheet can be used as required. 1. Pipe cutter 7. Screw driver 2.
... installation tools listed in this manual are the installation accessories we prepared. Drill with a diameter of 60mm 4. Leakage detector or soapy water 11. Hacksaw 3. Knife 9. Refrigerant oil The following parts mentioned in the following sheet can be used as required. 1. Pipe cutter 7. Screw driver 2.
User Manual
Page 15
... Suspending bolts 150mm 320mm 60mm Distance between suspending bolts 535mm Indoor unit 570mm Ceiling opening 650mm Ornament panel 700mm Ceiling Ornament panel (2) Prepare all piping (refrigerant,water drainage )and wires (connection wire of unit).
... Suspending bolts 150mm 320mm 60mm Distance between suspending bolts 535mm Indoor unit 570mm Ceiling opening 650mm Ornament panel 700mm Ceiling Ornament panel (2) Prepare all piping (refrigerant,water drainage )and wires (connection wire of unit).
User Manual
Page 19
... Gas Pipe 15.88mm Liquid Pipe 6.35mm Gas Pipe 12.7mm Joint Nut Tighten Torque (N. No leakage in the flare. (4) Piping connection Connecting method Smear refrigerant oil on and fasten (2).Pipe cutting and expanding Must remove burrs if cut pipes with pipe cutter.
... Gas Pipe 15.88mm Liquid Pipe 6.35mm Gas Pipe 12.7mm Joint Nut Tighten Torque (N. No leakage in the flare. (4) Piping connection Connecting method Smear refrigerant oil on and fasten (2).Pipe cutting and expanding Must remove burrs if cut pipes with pipe cutter.
User Manual
Page 20
...way valve 7 Valve rod cap 7 Valve rod cap 7 Service port cap Installation Procedures (4) Purging method ( the refrigerant is necessary to make flaring work again and vacuumize, fill up prescribed refrigerant from the gas cylinder. 3-way valve Service port 4 90 for 3-way valve and 3-way's a lottle more ...into vacuum pump. 2 Open the handle at low pressure side. If the scale-moves back in gaugemanifold and stop gas leakage, discharge whole refrigerants from the service port, open 3-way valve and 3-way. If leakage stops, then proceed 6 steps. 6 Detach the charge hose from ...
...way valve 7 Valve rod cap 7 Valve rod cap 7 Service port cap Installation Procedures (4) Purging method ( the refrigerant is necessary to make flaring work again and vacuumize, fill up prescribed refrigerant from the gas cylinder. 3-way valve Service port 4 90 for 3-way valve and 3-way's a lottle more ...into vacuum pump. 2 Open the handle at low pressure side. If the scale-moves back in gaugemanifold and stop gas leakage, discharge whole refrigerants from the service port, open 3-way valve and 3-way. If leakage stops, then proceed 6 steps. 6 Detach the charge hose from ...
User Manual
Page 23
...; Bi- Cracking sound is caused by indoor unit. Automatically switch into the FAN mode,but it stops. During operation, white fog comes out of the refrigerant , not a malfunction. Please wait for about three minutes after it will soon back to the cooling mode. Bi-î or ìGodo-Godoî. To...
...; Bi- Cracking sound is caused by indoor unit. Automatically switch into the FAN mode,but it stops. During operation, white fog comes out of the refrigerant , not a malfunction. Please wait for about three minutes after it will soon back to the cooling mode. Bi-î or ìGodo-Godoî. To...