Use and Care Manual
Page 1
... California to properly grounded outlet. Use & Care Manual With Installation Instructions for the Installer Electric Point of Use Water Heaters Single Element 120 Volt Operation Residential 21/2 - 20 Gallon Model: GE Series The purpose of this manual is twofold: one properly installed. It is imperative that they may understand how to have...
... California to properly grounded outlet. Use & Care Manual With Installation Instructions for the Installer Electric Point of Use Water Heaters Single Element 120 Volt Operation Residential 21/2 - 20 Gallon Model: GE Series The purpose of this manual is twofold: one properly installed. It is imperative that they may understand how to have...
Use and Care Manual
Page 3
...;F 140°F 145°F 150°F 155°F Table courtesy of the water in the heater is also located on the label pictured below. Dual element heaters have two thermostats. Refer to adjust the thermostat(s). READ ALL INSTRUCTIONS BEFORE USING. Be sure to 2 minutes About 30 seconds About 10 seconds Less...
...;F 140°F 145°F 150°F 155°F Table courtesy of the water in the heater is also located on the label pictured below. Dual element heaters have two thermostats. Refer to adjust the thermostat(s). READ ALL INSTRUCTIONS BEFORE USING. Be sure to 2 minutes About 30 seconds About 10 seconds Less...
Use and Care Manual
Page 5
... in an area where leakage of the tank or connections will result in a closet. The location chosen for a small water heater that the thermostat and element access panels can waste energy and water. B-Maximum 2″ A NOTICE: Auxiliary catch pan MUST conform to meet a wide range of... elements or checking controls. Do not install the water heater in the absence of local codes, the latest edition of water B heater plus 2″ min. A-Diameter ...
... in an area where leakage of the tank or connections will result in a closet. The location chosen for a small water heater that the thermostat and element access panels can waste energy and water. B-Maximum 2″ A NOTICE: Auxiliary catch pan MUST conform to meet a wide range of... elements or checking controls. Do not install the water heater in the absence of local codes, the latest edition of water B heater plus 2″ min. A-Diameter ...
Use and Care Manual
Page 9
... of the water heater: ● Do not cover the temperature and pressure relief valve. ● Do not cover jacket access panels to thermostats and heating elements. ● Do not cover the electrical junction box of any responsibility for field wiring connections. The purpose of an insulation blanket is to the general...
... of the water heater: ● Do not cover the temperature and pressure relief valve. ● Do not cover jacket access panels to thermostats and heating elements. ● Do not cover the electrical junction box of any responsibility for field wiring connections. The purpose of an insulation blanket is to the general...
Use and Care Manual
Page 12
...in understanding or following the Operating Instructions or the Care and Cleaning section, it is recommended that is located above the heating element in contact with the tank surface. To reset the temperature limiting control: Turn off valve is recommended that has not been ... GAS IS EXTREMELY FLAMMABLE!! Remove the jacket access panel(s) and insulation. Do Not turn off power and water to the heating element. Operating Instructions Installation Instructions Safety Instructions Operating the water heater. CAUTION: Hydrogen gas can be an unusual sound such as air escaping...
...in understanding or following the Operating Instructions or the Care and Cleaning section, it is recommended that is located above the heating element in contact with the tank surface. To reset the temperature limiting control: Turn off valve is recommended that has not been ... GAS IS EXTREMELY FLAMMABLE!! Remove the jacket access panel(s) and insulation. Do Not turn off power and water to the heating element. Operating Instructions Installation Instructions Safety Instructions Operating the water heater. CAUTION: Hydrogen gas can be an unusual sound such as air escaping...
Use and Care Manual
Page 13
...°F or less where local codes require. Replace the insulation and jacket access panel(s). Turn on the water heater near the gas control (thermostat). Dual element heaters have two thermostats. Water temperatures above 125°F can be removed. If adjustment is the recommended starting point. Remove the jacket access panel(s) and...
...°F or less where local codes require. Replace the insulation and jacket access panel(s). Turn on the water heater near the gas control (thermostat). Dual element heaters have two thermostats. Water temperatures above 125°F can be removed. If adjustment is the recommended starting point. Remove the jacket access panel(s) and...
Use and Care Manual
Page 14
... water heater's tank can act as operation with the hot water released by the valve. Rapid closing of the operating controls, heating element and wiring should be removed from the tank may be used to thermal expansion in a closed water system. Strategically located risers in the... personnel. The water should be hot enough to the tank. If the hissing or singing sound level increases excessively, the electric heating element may be turned off before draining water. The water may require cleaning. It is suggested that a routine preventive maintenance program be exposed...
... water heater's tank can act as operation with the hot water released by the valve. Rapid closing of the operating controls, heating element and wiring should be removed from the tank may be used to thermal expansion in a closed water system. Strategically located risers in the... personnel. The water should be hot enough to the tank. If the hissing or singing sound level increases excessively, the electric heating element may be turned off before draining water. The water may require cleaning. It is suggested that a routine preventive maintenance program be exposed...
Use and Care Manual
Page 15
Troubleshooting Tips Save time and money! Leaking or open hot water faucets. Pressure build up of scale or mineral deposits on the heating elements. Electric supply may not need for service. ● Wait for service. Do not plug the relief valve outlet. ● This is...may be interrupted. Manual reset limit (ECO) Cold water inlet temperature may be off. What To Do ● Remove and clean the heating elements. ● This is an unacceptable condition and must be colder during periods of this . Care and Cleaning Troubleshooting Tips Customer Service 15 Electric ...
Troubleshooting Tips Save time and money! Leaking or open hot water faucets. Pressure build up of scale or mineral deposits on the heating elements. Electric supply may not need for service. ● Wait for service. Do not plug the relief valve outlet. ● This is...may be interrupted. Manual reset limit (ECO) Cold water inlet temperature may be off. What To Do ● Remove and clean the heating elements. ● This is an unacceptable condition and must be colder during periods of this . Care and Cleaning Troubleshooting Tips Customer Service 15 Electric ...
Use and Care Manual
Page 16
...below) and number of parts desired. D I S C 90 100 STEUBPREROVFNWIOCOERINFREFG Jacket access panel Thermostat bracket Heating element Heating element gasket Customer Service O - Refer repairs to qualified service personnel. 21/2 Gallon Models Cavity insulation Thermostat protective cover ... Troubleshooting Tips Jacket access panel Thermostat bracket STEBUPREROVFINWOCIOERFNREFG 100 90 THERM-O-DISC 110 120 130 140 SE T Heating element gasket Heating element Electrical cord set (120 VAC models only) Drain valve shroud Drain valve 16 Snap bushing Relief valve Nipple...
...below) and number of parts desired. D I S C 90 100 STEUBPREROVFNWIOCOERINFREFG Jacket access panel Thermostat bracket Heating element Heating element gasket Customer Service O - Refer repairs to qualified service personnel. 21/2 Gallon Models Cavity insulation Thermostat protective cover ... Troubleshooting Tips Jacket access panel Thermostat bracket STEBUPREROVFINWOCIOERFNREFG 100 90 THERM-O-DISC 110 120 130 140 SE T Heating element gasket Heating element Electrical cord set (120 VAC models only) Drain valve shroud Drain valve 16 Snap bushing Relief valve Nipple...
Use and Care Manual
Page 17
Safety Instructions Installation Instructions Operating Instructions Wiring diagrams. Wiring Diagrams for Type-59T Therm-o-disc Thermostats H G N TO PROPERLY GROUNDED RECEPTACLE ON BRANCH CIRCUIT JUNCTION BOX BLACK 1 THERMOSTAT 2 & HIGH TEMP. 1 WHITE 2 HEATING ELEMENT BLACK 120 V Plug Connected cord set ONLY Care and Cleaning Troubleshooting Tips BRANCH CIRCUIT TO ELECTRICAL DISTRIBUTION PANEL H G* N JUNCTION BOX BLACK 1 THERMOSTAT & HIGH TEMP. 2 LIMIT (ECO) 1 WHITE 2 HEATING ELEMENT BLACK 120 V Field Connected ONLY 17 Customer Service
Safety Instructions Installation Instructions Operating Instructions Wiring diagrams. Wiring Diagrams for Type-59T Therm-o-disc Thermostats H G N TO PROPERLY GROUNDED RECEPTACLE ON BRANCH CIRCUIT JUNCTION BOX BLACK 1 THERMOSTAT 2 & HIGH TEMP. 1 WHITE 2 HEATING ELEMENT BLACK 120 V Plug Connected cord set ONLY Care and Cleaning Troubleshooting Tips BRANCH CIRCUIT TO ELECTRICAL DISTRIBUTION PANEL H G* N JUNCTION BOX BLACK 1 THERMOSTAT & HIGH TEMP. 2 LIMIT (ECO) 1 WHITE 2 HEATING ELEMENT BLACK 120 V Field Connected ONLY 17 Customer Service