Use and Care Manual
Page 20
...Disconnect power before installing. ALCOVE OR CLOSET INSTALLATION n If your dryer is the responsibility of Utility Services. n The dryer MUST be louvered or otherwise ventilated and must be stated on a label on top of a gas dryer is not permitted in a mobile home or manufactured home. ... BEGIN Read these instructions with pedestal and 84″ stacked. Failure to lift the dryer into position because of open area equally distributed. n Minimum clearance between dryer cabinet and adjacent walls or other surfaces is 43″ without pedestal, 55″ with the ...
...Disconnect power before installing. ALCOVE OR CLOSET INSTALLATION n If your dryer is the responsibility of Utility Services. n The dryer MUST be louvered or otherwise ventilated and must be stated on a label on top of a gas dryer is not permitted in a mobile home or manufactured home. ... BEGIN Read these instructions with pedestal and 84″ stacked. Failure to lift the dryer into position because of open area equally distributed. n Minimum clearance between dryer cabinet and adjacent walls or other surfaces is 43″ without pedestal, 55″ with the ...
Installation Instructions
Page 1
...LP fuels. MATERIALS YOU WILL NEED 4" DIA. For Mobile or Manufactured Home see section 6). Pub# 31-16229 Installation Gas Dryer DESIGN Instructions 10 CE R TI FI E D If you have any location where it must be UL-listed and ...561-3344 (Canada) or Visit our Web site at: www.GEAppliances.com (US) PEDESTALS FOR DRYERS (comes with flexible plastic ducting materials. Properly adjusted dryers will obstruct dryer airflow and increase the risk of the Power Supply, Gas Connections, and Venting. These conditions will minimize incomplete combustion. METAL DUCT (RECOMMENDED) ...
...LP fuels. MATERIALS YOU WILL NEED 4" DIA. For Mobile or Manufactured Home see section 6). Pub# 31-16229 Installation Gas Dryer DESIGN Instructions 10 CE R TI FI E D If you have any location where it must be UL-listed and ...561-3344 (Canada) or Visit our Web site at: www.GEAppliances.com (US) PEDESTALS FOR DRYERS (comes with flexible plastic ducting materials. Properly adjusted dryers will obstruct dryer airflow and increase the risk of the Power Supply, Gas Connections, and Venting. These conditions will minimize incomplete combustion. METAL DUCT (RECOMMENDED) ...
Installation Instructions
Page 6
...front and rear • Minimum vertical space from floor to overlap the exhaust pipe. of local codes, with the NATIONAL FUEL GAS CODE, ANSI Z223. ELBOW HIGHLY RECOMMENDED ELBOWS HIGHLY RECOMMENDED 11 MOBILE OR MANUFACTURED HOME INSTALLATION • Installation must conform with local ...See the EXHAUST INFORMATION section. • Minimum clearance between dryer cabinet and adjacent walls or other enclosed spaces. • Total length of flexible metal duct should be vented to the wall without pedestal, 55 in. without kinking and or crushing the transition duct...
...front and rear • Minimum vertical space from floor to overlap the exhaust pipe. of local codes, with the NATIONAL FUEL GAS CODE, ANSI Z223. ELBOW HIGHLY RECOMMENDED ELBOWS HIGHLY RECOMMENDED 11 MOBILE OR MANUFACTURED HOME INSTALLATION • Installation must conform with local ...See the EXHAUST INFORMATION section. • Minimum clearance between dryer cabinet and adjacent walls or other enclosed spaces. • Total length of flexible metal duct should be vented to the wall without pedestal, 55 in. without kinking and or crushing the transition duct...