... (50.8) 5 (12.7) All dimensions are available in the vicinity of the cooktop. pages 1-6 Español - LENGTH 25 ¾ (65.4) 30 ¾ (78.1) 30 (76.2) 32 ¼ (81.9) 32 ¼ (81.9) 36 ¾ (93.3) 36 (91.4) 36 (91.4) B. MIN. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. for unprotected cabinet 24" (61 cm) min. LENGTH E. pages...
... (50.8) 5 (12.7) All dimensions are available in the vicinity of the cooktop. pages 1-6 Español - LENGTH 25 ¾ (65.4) 30 ¾ (78.1) 30 (76.2) 32 ¼ (81.9) 32 ¼ (81.9) 36 ¾ (93.3) 36 (91.4) 36 (91.4) B. MIN. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. for unprotected cabinet 24" (61 cm) min. LENGTH E. pages...
Installation Instructions (All Languages)
Page 2
... cabinet storage is needed for G, H and J. MODEL 26" Coil Elements 30" Ceramic-Glass 30" Coil Elements 32" Ceramic-Glass 32" Coil Elements 36" Ceramic-Glass 36" Coil Elements (36" X 18") 36" Coil Elements (36" X 21½") G 3" (7.6 cm) 7½" (19.1 cm) 7½" (19.1 cm) 7½" (19.1 cm) 7½" (19.1 cm) 7½" (19.1 cm) 3" (7.6 cm) H... Location of Cutout and Nearest Combustible Surface Above Countertop 18" (45.7 cm) 10" ( 25.4 cm) 25" Min. (63.5 cm Min.) G Min. ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS Overhead Cabinet Should Not Exceed a Maximum Depth of the cabinets.
... cabinet storage is needed for G, H and J. MODEL 26" Coil Elements 30" Ceramic-Glass 30" Coil Elements 32" Ceramic-Glass 32" Coil Elements 36" Ceramic-Glass 36" Coil Elements (36" X 18") 36" Coil Elements (36" X 21½") G 3" (7.6 cm) 7½" (19.1 cm) 7½" (19.1 cm) 7½" (19.1 cm) 7½" (19.1 cm) 7½" (19.1 cm) 3" (7.6 cm) H... Location of Cutout and Nearest Combustible Surface Above Countertop 18" (45.7 cm) 10" ( 25.4 cm) 25" Min. (63.5 cm Min.) G Min. ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS Overhead Cabinet Should Not Exceed a Maximum Depth of the cabinets.
Installation Instructions (All Languages)
Page 4
...zone) from the power supply cable if a 3-wire appliance cable is grounded inside the house service panel. Only Models 36" with local electrical codes. Connect the remaining wires from the supply cable to the matching color wires from the appliance cable (see Figure...be used to ground the appliance in accordance with Warmer Zone Only 3-WIRE GROUNDED JUNCTION BOX WARNING Improper connection of the 4-wire electrical system. ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS This appliance is supplied) to the power supply cable white wire. U.S.A. Connect the appliance white wire (if a ...
...zone) from the power supply cable if a 3-wire appliance cable is grounded inside the house service panel. Only Models 36" with local electrical codes. Connect the remaining wires from the supply cable to the matching color wires from the appliance cable (see Figure...be used to ground the appliance in accordance with Warmer Zone Only 3-WIRE GROUNDED JUNCTION BOX WARNING Improper connection of the 4-wire electrical system. ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS This appliance is supplied) to the power supply cable white wire. U.S.A. Connect the appliance white wire (if a ...
Installation Instructions (All Languages)
Page 5
...to the counter with CSA Standard C22.1, Canadian Electrical Code, Part 1 (see Figure 10). 5 The retainer brackets MUST be removable for damage. Figure 10 2. Models: 26" and 36" (36" X 18") Coil Elements Cooktops Set the cooktop into the countertop cutout. Align the knobs on... the edges of the box to meet local codes or, in "Electrical Connection" section. The cooktop must clamp unit down information. COOKTOP COUNTERTOP NYLON SPACER Retainer Brackets...
...to the counter with CSA Standard C22.1, Canadian Electrical Code, Part 1 (see Figure 10). 5 The retainer brackets MUST be removable for damage. Figure 10 2. Models: 26" and 36" (36" X 18") Coil Elements Cooktops Set the cooktop into the countertop cutout. Align the knobs on... the edges of the box to meet local codes or, in "Electrical Connection" section. The cooktop must clamp unit down information. COOKTOP COUNTERTOP NYLON SPACER Retainer Brackets...
Installation Instructions (All Languages)
Page 6
... serial numbers and a lot number or letter from the serial plate on your Owner's Guide for our service phone number and address. ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS Reach down through surface unit openings and install the four hold down retainers with offset side of angle into countertop opening , ...burner box to the warranty in cutout. It may be seen by lifting up the main top of unit. Models: 30" and 36" (36" X 21½") Coil Elements Cooktops - Once unit is firmly retained to fit various cutout sizes. Before You Call for operation. Tighten all screws evenly. 5. Be...
... serial numbers and a lot number or letter from the serial plate on your Owner's Guide for our service phone number and address. ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS Reach down through surface unit openings and install the four hold down retainers with offset side of angle into countertop opening , ...burner box to the warranty in cutout. It may be seen by lifting up the main top of unit. Models: 30" and 36" (36" X 21½") Coil Elements Cooktops - Once unit is firmly retained to fit various cutout sizes. Before You Call for operation. Tighten all screws evenly. 5. Be...