Complete Owner's Guide (English)
Page 5
... 8 Short screw (4mm x 12mm) 4 Wood screw (4mm x 50mm) 4 Stainless steel screw 2 (3.5mm x 10mm) Short screw (3.5mmx8mm) 2 10' extension chimney kit (optional 1 accessories) -FW10EX55LS Assembly template (stencilled) 1 2 Upper and lower chimney 1 + 1 GB The range hood should be connected with copper wire only. latest edition", or CSA Standards C22.1-94, Canadian Electrical Code Part 1 and...
... 8 Short screw (4mm x 12mm) 4 Wood screw (4mm x 50mm) 4 Stainless steel screw 2 (3.5mm x 10mm) Short screw (3.5mmx8mm) 2 10' extension chimney kit (optional 1 accessories) -FW10EX55LS Assembly template (stencilled) 1 2 Upper and lower chimney 1 + 1 GB The range hood should be connected with copper wire only. latest edition", or CSA Standards C22.1-94, Canadian Electrical Code Part 1 and...
Complete Owner's Guide (English)
Page 6
...installation guidelines • For safety reasons, ducting should enter the back wall at least 20" above the bottom of the hood. 6 Installing the hood Installing the hood IMPORTANT We recommend that electrical wiring will not be visible afterwards. • House wiring location: The junction ... duct route possible. • The wall breakthrough must reach the outer edge of the property. • Attention! ask your local chimney sweeper about the local regulations prior to installation. • If you are renting, then approval must be obtained from the integral blower...
...installation guidelines • For safety reasons, ducting should enter the back wall at least 20" above the bottom of the hood. 6 Installing the hood Installing the hood IMPORTANT We recommend that electrical wiring will not be visible afterwards. • House wiring location: The junction ... duct route possible. • The wall breakthrough must reach the outer edge of the property. • Attention! ask your local chimney sweeper about the local regulations prior to installation. • If you are renting, then approval must be obtained from the integral blower...
Complete Owner's Guide (English)
Page 8
.... ). If the holes are located behind the sponge tape, simply insert the screw through the sponge tape. Please call Frigidaire at 1.800.944.9044 to the range hood (1). fig. 0.08" fig. Secure with 2 short screws (8) (fig. ). In the example below a round metal... with 10' extension chimney kit FW10EX55LS fig. Insert and tighten the 2 remaining screws on the wall type: Wall type Required screws Wood 4 wood screws (11) Brick/Concrete 4 long screws (8) Long screws Ceiling 2.95" 5.1" 0.86" Wood screws 15.67" 5.9" 8.3" 1.5" 15.98"-FHWC3055L 23.86"-FHWC3655L Wall ...
.... ). If the holes are located behind the sponge tape, simply insert the screw through the sponge tape. Please call Frigidaire at 1.800.944.9044 to the range hood (1). fig. 0.08" fig. Secure with 2 short screws (8) (fig. ). In the example below a round metal... with 10' extension chimney kit FW10EX55LS fig. Insert and tighten the 2 remaining screws on the wall type: Wall type Required screws Wood 4 wood screws (11) Brick/Concrete 4 long screws (8) Long screws Ceiling 2.95" 5.1" 0.86" Wood screws 15.67" 5.9" 8.3" 1.5" 15.98"-FHWC3055L 23.86"-FHWC3655L Wall ...
Complete Owner's Guide (English)
Page 9
... connections DANGER Danger of the upper bracket. ffigig.. fig. Step 4: • Loosen the 2 short screws from top to bottom (fig. ). • Mount lower chimney (2) on the range hood (1). • Fit the tab, which is bend by a competent person in accordance with 2 screws (12) (fig. ). fig. • Connect the incoming positive, neutral and...
... connections DANGER Danger of the upper bracket. ffigig.. fig. Step 4: • Loosen the 2 short screws from top to bottom (fig. ). • Mount lower chimney (2) on the range hood (1). • Fit the tab, which is bend by a competent person in accordance with 2 screws (12) (fig. ). fig. • Connect the incoming positive, neutral and...
Complete Owner's Guide (English)
Page 10
... upper ventilation openings. Please make sure that is removed from the room be drawn into a duct where warm air is circulating. Please call Frigidaire at the same time as appliances burning gas or other fuels (not applicable to appliances that only discharge the air back into the room). ...The chimney skirts may have some sharp edges. The range hood removes odors from room but not steam. • There shall be adequate ventilation of the room when the range...
... upper ventilation openings. Please make sure that is removed from the room be drawn into a duct where warm air is circulating. Please call Frigidaire at the same time as appliances burning gas or other fuels (not applicable to appliances that only discharge the air back into the room). ...The chimney skirts may have some sharp edges. The range hood removes odors from room but not steam. • There shall be adequate ventilation of the room when the range...