Product Specifications Sheet
Page 2
...to Product Installation Guide for detailed installation instructions on the web at frigidaire.com. Ft.) Oven Light Rack Configuration Baking System Broiling System Bake Burner / Broil Burner (BTU) Drawer Racks OPTIONAL ACCESSORIES LP Gas Conversion Kit Griddle CERTIFICATIONS Star-K® Certified (Sabbath Mode) SPECIFICATIONS Oven Interior (...• Mississauga, ON L5V 3E4 • 1-800-265-8352 • frigidaire.ca FGGF3047T 10/17 © 2017 Electrolux Home Products, Inc. Depth (Incl. FGGF3047TF FREESTANDING RANGE 30" GAS FEATURES Oven Control / Timing System Surface Type Sealed ...
...to Product Installation Guide for detailed installation instructions on the web at frigidaire.com. Ft.) Oven Light Rack Configuration Baking System Broiling System Bake Burner / Broil Burner (BTU) Drawer Racks OPTIONAL ACCESSORIES LP Gas Conversion Kit Griddle CERTIFICATIONS Star-K® Certified (Sabbath Mode) SPECIFICATIONS Oven Interior (...• Mississauga, ON L5V 3E4 • 1-800-265-8352 • frigidaire.ca FGGF3047T 10/17 © 2017 Electrolux Home Products, Inc. Depth (Incl. FGGF3047TF FREESTANDING RANGE 30" GAS FEATURES Oven Control / Timing System Surface Type Sealed ...
Product Specifications Sheet
Page 3
... only. Refer to model's product specifications for actual dimensions. 36" (Adjustable to change. OPTIONAL ACCESSORIES • LP Gas Conversion Kit - (PN # GRLP4). • Griddle - Specifications subject to ±1/8") INSTALLATION SPECIFICATIONS • Product Shipping Weight...LP Gas convertible. (Optional LP Gas conversion kit available.) • Floor beneath range MUST be capable of withstanding minimum heat of 90° F above 36" height Wall CL 18" min. 30" 111/2" 23" 8" 36" stand. 46 5/8" 15" 101/2" 2" 24" Recommended area for 120V outlet on the web at frigidaire...
... only. Refer to model's product specifications for actual dimensions. 36" (Adjustable to change. OPTIONAL ACCESSORIES • LP Gas Conversion Kit - (PN # GRLP4). • Griddle - Specifications subject to ±1/8") INSTALLATION SPECIFICATIONS • Product Shipping Weight...LP Gas convertible. (Optional LP Gas conversion kit available.) • Floor beneath range MUST be capable of withstanding minimum heat of 90° F above 36" height Wall CL 18" min. 30" 111/2" 23" 8" 36" stand. 46 5/8" 15" 101/2" 2" 24" Recommended area for 120V outlet on the web at frigidaire...
Installation Instructions
Page 6
..., inlet pressure must be at elevations above sea level. Fig. 9 6 FREESTANDING GAS RANGE 2 Provide an adequate gas supply. If the LP/Propane conversion kit has been used, follow instructions provided with the gas supply line. b. of the gas pressure regulator before tightening ANY fittings to gas...regulator to turn on pipe when tightening fittings (Refer to gas pressure regulator using no more than 14 inches of 4 percent for LP/Propane gas 10 inch manifold pressure, inlet pressure must be conducted according to Fig. 8). Note: To prevent leaks use . a. The...
..., inlet pressure must be at elevations above sea level. Fig. 9 6 FREESTANDING GAS RANGE 2 Provide an adequate gas supply. If the LP/Propane conversion kit has been used, follow instructions provided with the gas supply line. b. of the gas pressure regulator before tightening ANY fittings to gas...regulator to turn on pipe when tightening fittings (Refer to gas pressure regulator using no more than 14 inches of 4 percent for LP/Propane gas 10 inch manifold pressure, inlet pressure must be conducted according to Fig. 8). Note: To prevent leaks use . a. The...