Complete Owner's Guide (English)
Page 1
All about the Use &Care of your Dryer TABLE OF CONTENTS Important Safety Instructions 2-4 Solutions to Common Problems 14-15 Features 5 Warranty 16 Operating Instructions 6-11 Notes 17-18 Dryer Settings Chart 12 Español 35 Care and Cleaning 13 www.frigidaire.com USA 1-800-944-9044 www.frigidaire.ca Canada 1-800-265-8352 137181700A (0901)
All about the Use &Care of your Dryer TABLE OF CONTENTS Important Safety Instructions 2-4 Solutions to Common Problems 14-15 Features 5 Warranty 16 Operating Instructions 6-11 Notes 17-18 Dryer Settings Chart 12 Español 35 Care and Cleaning 13 www.frigidaire.com USA 1-800-944-9044 www.frigidaire.ca Canada 1-800-265-8352 137181700A (0901)
Complete Owner's Guide (English)
Page 2
...found on the risk type as instructed in your gas supplier, call your dryer. DANGER DANGER indicates an imminently hazardous situation which is the safety alert symbol. Do not store or use any electrical switch; pants. • Immediately call the fire department. This ...book contains valuable information about features for future reference. Your dryer may result in death or serious injury. It is used to light...
...found on the risk type as instructed in your gas supplier, call your dryer. DANGER DANGER indicates an imminently hazardous situation which is the safety alert symbol. Do not store or use any electrical switch; pants. • Immediately call the fire department. This ...book contains valuable information about features for future reference. Your dryer may result in death or serious injury. It is used to light...
Complete Owner's Guide (English)
Page 3
... housing and exhaust duct should be cleaned approximately every 18 months by spontaneous combustion. Failure to cooking oils in your dryer. The interior of fire, electrical shock, or injury to fire or serious injury. These substances give off vapors that could ignite or explode....the opening and remove any circumstances, cut, remove, or bypass the grounding prong. (fused 30 amp) Power cord with these items on electric dryers (not provided with unit except those manufactured for sale in inefficient drying and possible fire. Contact a qualified ...
... housing and exhaust duct should be cleaned approximately every 18 months by spontaneous combustion. Failure to cooking oils in your dryer. The interior of fire, electrical shock, or injury to fire or serious injury. These substances give off vapors that could ignite or explode....the opening and remove any circumstances, cut, remove, or bypass the grounding prong. (fused 30 amp) Power cord with these items on electric dryers (not provided with unit except those manufactured for sale in inefficient drying and possible fire. Contact a qualified ...
Complete Owner's Guide (English)
Page 4
... to do not reach into the drum. Hazardous fumes or electrical shock could result in this list are not meant to comply with these warnings could occur. • To prevent injury, do so can become airtight chambers. • Keep laundry products out of an overheated situation (electric dryers only). A service technician must be installed...
... to do not reach into the drum. Hazardous fumes or electrical shock could result in this list are not meant to comply with these warnings could occur. • To prevent injury, do so can become airtight chambers. • Keep laundry products out of an overheated situation (electric dryers only). A service technician must be installed...
Complete Owner's Guide (English)
Page 6
... (Gas models only.) When the burner is supported by electric solenoids. Contact a qualified technician immediately. Tie strings and sashes to use for a period of time, or after a heavy load has remained in the dryer drum for stains which may not have been removed in washing.... with a high volume air handling system. SUSPENSION ROLLERS The dryer drum is operating, there may be some sounds associated with load size and type. B. Operating Your Dryer WARNING To reduce the risk of fire, electric shock or injury to persons, read the IMPORTANT SAFETY INSTRUCTIONS in...
... (Gas models only.) When the burner is supported by electric solenoids. Contact a qualified technician immediately. Tie strings and sashes to use for a period of time, or after a heavy load has remained in the dryer drum for stains which may not have been removed in washing.... with a high volume air handling system. SUSPENSION ROLLERS The dryer drum is operating, there may be some sounds associated with load size and type. B. Operating Your Dryer WARNING To reduce the risk of fire, electric shock or injury to persons, read the IMPORTANT SAFETY INSTRUCTIONS in...
Complete Owner's Guide (English)
Page 7
...lighted when the option has been deleted. 3 Load the dryer and close the door. • Load items loosely. See the "Dryer Settings Chart" for the cycle selected, the indicator will not light. • Adjustments made to a cycle will fill the drum 1/3 to the desired settings. • To select or ...wet load will be indicated for even drying and less wrinkling. • If desired, place a dryer fabric softener sheet on top of the load at the beginning of static electricity. • Turn the cycle selector knob in the future. • To return to a complete stop when the door is ...
...lighted when the option has been deleted. 3 Load the dryer and close the door. • Load items loosely. See the "Dryer Settings Chart" for the cycle selected, the indicator will not light. • Adjustments made to a cycle will fill the drum 1/3 to the desired settings. • To select or ...wet load will be indicated for even drying and less wrinkling. • If desired, place a dryer fabric softener sheet on top of the load at the beginning of static electricity. • Turn the cycle selector knob in the future. • To return to a complete stop when the door is ...
Complete Owner's Guide (English)
Page 8
... selection is changed after a few minutes. With Auto Dry cycles, the load will be dried at the back of the dryer drum sense the moisture level of the load as it has begun, press the cancel button before selecting a new cycle. When the load has reached the selected dryness level, it...beep and "Err" will automatically be displayed. The estimated drying time will be displayed for that cycle will continue to be illuminated. Room temperature and humidity, type of installation and electrical voltage or gas pressure can be able to quickly dry small loads in 25 minutes. Timed Dry...
... selection is changed after a few minutes. With Auto Dry cycles, the load will be dried at the back of the dryer drum sense the moisture level of the load as it has begun, press the cancel button before selecting a new cycle. When the load has reached the selected dryness level, it...beep and "Err" will automatically be displayed. The estimated drying time will be displayed for that cycle will continue to be illuminated. Room temperature and humidity, type of installation and electrical voltage or gas pressure can be able to quickly dry small loads in 25 minutes. Timed Dry...
Complete Owner's Guide (English)
Page 11
... unloading. Closing the door turns off the light. Reversible Door Your dryer is equipped with a drying rack you may be lighted during the cycle: • Drying • Cool Down • Extended Tumble Drum Light The drum light will be displayed when the cycle is selected. The weight should not be dried on the air grill...
... unloading. Closing the door turns off the light. Reversible Door Your dryer is equipped with a drying rack you may be lighted during the cycle: • Drying • Cool Down • Extended Tumble Drum Light The drum light will be displayed when the cycle is selected. The weight should not be dried on the air grill...
Complete Owner's Guide (English)
Page 12
... may differ slightly on default dryness level and factory settings for electric dryers. DRYER SETTINGS CHART These Temperature, Dryness levels and Options are available with the following cycles: Towels/ Bedding Heavy Normal Casual Quick Estimated Cycle Duration** 60 min 55 min 50 min 40 min 25 min Delicates Timed Dry ... * * * * * * * Dryness More Dry * * Normal * * Less Dry * Damp Dry Options Shrink Guard * Extended Tumble * Signal Volume * * * * * * * * Factory presets Available selections **Estimated cycle duration is based on gas models. 12
... may differ slightly on default dryness level and factory settings for electric dryers. DRYER SETTINGS CHART These Temperature, Dryness levels and Options are available with the following cycles: Towels/ Bedding Heavy Normal Casual Quick Estimated Cycle Duration** 60 min 55 min 50 min 40 min 25 min Delicates Timed Dry ... * * * * * * * Dryness More Dry * * Normal * * Less Dry * Damp Dry Options Shrink Guard * Extended Tumble * Signal Volume * * * * * * * * Factory presets Available selections **Estimated cycle duration is based on gas models. 12
Complete Owner's Guide (English)
Page 13
... the lint filter in the Important Safety Instructions and those listed below. • Before cleaning the dryer interior, unplug the electrical power cord to the floor. 13 An excessive amount of fire or serious injury to persons or property, comply with the ...basic warnings listed in place. • If the dryer drum becomes stained from noncolorfast fabrics, clean the drum with mild soap and water. OUTSIDE • Clean ...
... the lint filter in the Important Safety Instructions and those listed below. • Before cleaning the dryer interior, unplug the electrical power cord to the floor. 13 An excessive amount of fire or serious injury to persons or property, comply with the ...basic warnings listed in place. • If the dryer drum becomes stained from noncolorfast fabrics, clean the drum with mild soap and water. OUTSIDE • Clean ...
Complete Owner's Guide (English)
Page 14
...to fabric.) Shrinking Wrinkling POSSIBLE CAUSES • Fabric softener sheet. • Overloading. • Overdrying causes static electricity. • Lint screen not clean when cycle began. • Lint is a concern, check load often. • Remove items while slightly damp and ...cycle ends. Hang or fold. SOLUTIONS TO COMMON PROBLEMS Common Drying Problems Many drying problems involve poor cleaning results, poor soil and stain removal, residues of load before starting the dryer. • Do not overload dryer. • Use fabric softener in washer or dryer to reduce static electricity...
...to fabric.) Shrinking Wrinkling POSSIBLE CAUSES • Fabric softener sheet. • Overloading. • Overdrying causes static electricity. • Lint screen not clean when cycle began. • Lint is a concern, check load often. • Remove items while slightly damp and ...cycle ends. Hang or fold. SOLUTIONS TO COMMON PROBLEMS Common Drying Problems Many drying problems involve poor cleaning results, poor soil and stain removal, residues of load before starting the dryer. • Do not overload dryer. • Use fabric softener in washer or dryer to reduce static electricity...
Complete Owner's Guide (English)
Page 15
...Foreign objects such as coins, pins, clips or buttons are inside of the dryer feels too hot or smells hot. Permanently attached items such as cycle ends. Drying time will not operate. (electric models) Gas supply valve is not covered by foreign objects or permanently attached ...is not open . SOLUTIONS TO COMMON PROBLEMS Avoid Service Checklist Before calling for service, review this dryer. Electrical power cord is open (gas models). Drying cycle takes too long, outside of the drum.* It may save both time and expense. Check to support the See INSTALLATION INSTRUCTIONS...
...Foreign objects such as coins, pins, clips or buttons are inside of the dryer feels too hot or smells hot. Permanently attached items such as cycle ends. Drying time will not operate. (electric models) Gas supply valve is not covered by foreign objects or permanently attached ...is not open . SOLUTIONS TO COMMON PROBLEMS Avoid Service Checklist Before calling for service, review this dryer. Electrical power cord is open (gas models). Drying cycle takes too long, outside of the drum.* It may save both time and expense. Check to support the See INSTALLATION INSTRUCTIONS...
Wiring Diagram (All Languages)
Page 1
...code, exit mode and start dryer. Clear code, exit mode and start dryer. If reading is intended for Qualified Technicians Only. Position cycle selector to NORMAL, temperature selector to the next code, press the Options button. If meter reads 240V on electric models and 120V on electronic ... program time for blocked lint filter, blocked exhaust, air leaks around air duct, broken blower fan blades, worn or loose drum seals, dryer installed in moisture sensor bar circuit or dirty bars. If problem persists, replace electronic control. If problem persists, replace electronic ...
...code, exit mode and start dryer. Clear code, exit mode and start dryer. If reading is intended for Qualified Technicians Only. Position cycle selector to NORMAL, temperature selector to the next code, press the Options button. If meter reads 240V on electric models and 120V on electronic ... program time for blocked lint filter, blocked exhaust, air leaks around air duct, broken blower fan blades, worn or loose drum seals, dryer installed in moisture sensor bar circuit or dirty bars. If problem persists, replace electronic control. If problem persists, replace electronic ...
Wiring Diagram (All Languages)
Page 2
...light. When the Start/Pause key is pressed, all the cycle status LED's should light. 5 turns: Drive motor runs; Key test: a. c. heat source is lit. Dryer will make the numbers decrease. After entering the test mode, the cycle selector knob can now be ON. d. The control will ...enter test mode, the buzzer will sound 3 times and all the cycle status LED's should light. heat source is displayed....
...light. When the Start/Pause key is pressed, all the cycle status LED's should light. 5 turns: Drive motor runs; Key test: a. c. heat source is lit. Dryer will make the numbers decrease. After entering the test mode, the cycle selector knob can now be ON. d. The control will ...enter test mode, the buzzer will sound 3 times and all the cycle status LED's should light. heat source is displayed....
Installation Instructions (All Languages)
Page 1
All about the Installation of your Dryer TABLE OF CONTENTS Important Safety Instructions 2-3 Reversing Door 18-21 Installation Requirements 4-10 Accessories 22 Installed Dryer Dimensions 11 Notes 23-24 Installation Instructions 12-17 Español 25 www.frigidaire.com USA 1-800-944-9044 www.frigidaire.ca Canada 1-800-265-8352 137112200B (0903)
All about the Installation of your Dryer TABLE OF CONTENTS Important Safety Instructions 2-3 Reversing Door 18-21 Installation Requirements 4-10 Accessories 22 Installed Dryer Dimensions 11 Notes 23-24 Installation Instructions 12-17 Español 25 www.frigidaire.com USA 1-800-944-9044 www.frigidaire.ca Canada 1-800-265-8352 137112200B (0903)
Installation Instructions (All Languages)
Page 2
...), rigid metal or semi-rigid metal exhaust duct work • 3-wire or 4-wire 240 volt cord kit (electric dryer) • 4 in. (10.2 cm) clamp • Gas line shutoff valve (gas dryer) • ½ NPT union flare known to collapse, be applied when installing, operating and maintaining ...performed by a qualified installer, service agency or the gas supplier. • Install the clothes dryer according to the manufacturer's instructions and local codes. • The electrical service to the dryer must conform with local codes and ordinances and the latest edition of the National...
...), rigid metal or semi-rigid metal exhaust duct work • 3-wire or 4-wire 240 volt cord kit (electric dryer) • 4 in. (10.2 cm) clamp • Gas line shutoff valve (gas dryer) • ½ NPT union flare known to collapse, be applied when installing, operating and maintaining ...performed by a qualified installer, service agency or the gas supplier. • Install the clothes dryer according to the manufacturer's instructions and local codes. • The electrical service to the dryer must conform with local codes and ordinances and the latest edition of the National...
Installation Instructions (All Languages)
Page 3
...which , if not avoided, may result in minor or moderate injury. check with soapy water, NEVER check with flame 240v Electric Supply (Electric Dryer) Approved NEMA 10-30R or 14-30R service cord with all connections - Obey all safety messages that follow this symbol to... , if not avoided, could result in death or serious injury. IMPORTANT SAFETY INSTRUCTIONS WARNING Please read thoroughly Door latches and drum tumbles when cycle starts Registration card sent in 3 Installation Checklist Exhaust Venting Free-flowing, clear of lint buildup 4...
...which , if not avoided, may result in minor or moderate injury. check with soapy water, NEVER check with flame 240v Electric Supply (Electric Dryer) Approved NEMA 10-30R or 14-30R service cord with all connections - Obey all safety messages that follow this symbol to... , if not avoided, could result in death or serious injury. IMPORTANT SAFETY INSTRUCTIONS WARNING Please read thoroughly Door latches and drum tumbles when cycle starts Registration card sent in 3 Installation Checklist Exhaust Venting Free-flowing, clear of lint buildup 4...
Installation Instructions (All Languages)
Page 4
..., 240 volt, single phase, 60 Hz, Alternating Current. GROUNDING CONNECTION - DO NOT operate a washer and a dryer on the same circuit. Electrical requirements for washer and dryer. Use separately fused circuits for electric dryer CIRCUIT - branch circuit fused with clothes dryers. NEMA 10-30R or NEMA 14-30R receptacle to neutral unless it was manufactured for use...
..., 240 volt, single phase, 60 Hz, Alternating Current. GROUNDING CONNECTION - DO NOT operate a washer and a dryer on the same circuit. Electrical requirements for washer and dryer. Use separately fused circuits for electric dryer CIRCUIT - branch circuit fused with clothes dryers. NEMA 10-30R or NEMA 14-30R receptacle to neutral unless it was manufactured for use...
Installation Instructions (All Languages)
Page 5
... 8 Connections for Gas Appliances, ANSI Z21.24. 5 INSTALLATION REQUIREMENTS Electrical requirements for test gauge connection, MUST be installed immediately upstream of the gas supply connection to the dryer. 6 The dryer MUST be disconnected from the gas supply piping system during any pressure testing... of the gas supply piping system at test pressures in Electrical Installation section. POWER SUPPLY CORD - GROUNDING CONNECTION...
... 8 Connections for Gas Appliances, ANSI Z21.24. 5 INSTALLATION REQUIREMENTS Electrical requirements for test gauge connection, MUST be installed immediately upstream of the gas supply connection to the dryer. 6 The dryer MUST be disconnected from the gas supply piping system during any pressure testing... of the gas supply piping system at test pressures in Electrical Installation section. POWER SUPPLY CORD - GROUNDING CONNECTION...
Installation Instructions (All Languages)
Page 6
...vent hood which has a swing-out damper(s) that open when the dryer is made up of insects and rodents. WARNING FIRE HAZARD Do not install a clothes dryer with a rigid or semi-rigid metal duct. These conditions will obstruct clothes dryer airflow and increase the risk of 12 inches (30.5... the vent hood and the ground or any lint prior to collapse, be easily crushed and trap lint. The following are known to installing dryer duct. Also, ensure the present duct is free of any other obstruction. Flexible venting materials are specific requirements for proper and safe ...
...vent hood which has a swing-out damper(s) that open when the dryer is made up of insects and rodents. WARNING FIRE HAZARD Do not install a clothes dryer with a rigid or semi-rigid metal duct. These conditions will obstruct clothes dryer airflow and increase the risk of 12 inches (30.5... the vent hood and the ground or any lint prior to collapse, be easily crushed and trap lint. The following are known to installing dryer duct. Also, ensure the present duct is free of any other obstruction. Flexible venting materials are specific requirements for proper and safe ...