BOOK INSTL VENT FRAME FP USA (English, French)
Page 1
..., please then refer back to your main Installation instructions to complete the installation of your product explains how to this booklet are installing the external venting kit into framed cabinetry only For customers with framed cabinetry only The supplied Installation Instructions booklet provided with your dishwasher. The instructions in this booklet...
..., please then refer back to your main Installation instructions to complete the installation of your product explains how to this booklet are installing the external venting kit into framed cabinetry only For customers with framed cabinetry only The supplied Installation Instructions booklet provided with your dishwasher. The instructions in this booklet...
BOOK INSTL VENT FRAME FP USA (English, French)
Page 2
...HOSE + POWER CORD Frame 8 11⁄16" (220 mm) 1" (25 mm) 1b INTEGRATED MODELS ONLY - PREPARATION FOR EXTERNAL VENTING THROUGH ADJACENT CABINET Services can be located either side of dishwasher If the services holes are through metal, ensure you do not cut ...mm) ø 2 3⁄8" (60 mm) 4" (100 mm) Important! PREPARATION FOR EXTERNAL VENTING THROUGH SAME CABINET 2 Services can be located either side of dishwasher VENT HOSE ø 2 3⁄8" (60 mm) ø max. 1½"(38 mm) Important! VENT HOSE + DRAIN HOSE + INLET HOSE ø max. 1½" (38 mm) ø...
...HOSE + POWER CORD Frame 8 11⁄16" (220 mm) 1" (25 mm) 1b INTEGRATED MODELS ONLY - PREPARATION FOR EXTERNAL VENTING THROUGH ADJACENT CABINET Services can be located either side of dishwasher If the services holes are through metal, ensure you do not cut ...mm) ø 2 3⁄8" (60 mm) 4" (100 mm) Important! PREPARATION FOR EXTERNAL VENTING THROUGH SAME CABINET 2 Services can be located either side of dishwasher VENT HOSE ø 2 3⁄8" (60 mm) ø max. 1½"(38 mm) Important! VENT HOSE + DRAIN HOSE + INLET HOSE ø max. 1½" (38 mm) ø...
BOOK INSTL VENT FRAME FP USA (English, French)
Page 3
2 UNSCREW TOP COVER FROM EXTERNAL VENT 3 THE SHADED AREAS HAVE TO BE REMOVED. 3 FIRST, CUT DOWN FRONT FACE WITH A KNIFE 4 CUT OFF REMAINING PLASTIC FROM EACH SIDE Important! Ensure you perform this step on the countertop or floor. 5 LOOSELY ASSEMBLE THE EXTERNAL VENT TOGETHER. THE VENT IS NOW MODIFIED AND READY TO INSTALL Snap off Score with Knife Do not cut on 19 a chopping board or similiar.
2 UNSCREW TOP COVER FROM EXTERNAL VENT 3 THE SHADED AREAS HAVE TO BE REMOVED. 3 FIRST, CUT DOWN FRONT FACE WITH A KNIFE 4 CUT OFF REMAINING PLASTIC FROM EACH SIDE Important! Ensure you perform this step on the countertop or floor. 5 LOOSELY ASSEMBLE THE EXTERNAL VENT TOGETHER. THE VENT IS NOW MODIFIED AND READY TO INSTALL Snap off Score with Knife Do not cut on 19 a chopping board or similiar.
BOOK INSTL VENT FRAME FP USA (English, French)
Page 4
Insert bracket into vent slot and secure to the fitted elbow at the back of the product (as per main Installation instructions). 6 ATTACH THE HOSE TO THE VENT & POSITION IN CUTOUT 7 SECURE THE EXTERNAL VENT USING 4 BRACKET & SCREWS Important! Ensure that the venting hose was attached to shelf with screw Screw vent together with the 4 screws 1 After routing the vent hose through and out the hole cutout, attach and secure the vent. 2 Airflow
Insert bracket into vent slot and secure to the fitted elbow at the back of the product (as per main Installation instructions). 6 ATTACH THE HOSE TO THE VENT & POSITION IN CUTOUT 7 SECURE THE EXTERNAL VENT USING 4 BRACKET & SCREWS Important! Ensure that the venting hose was attached to shelf with screw Screw vent together with the 4 screws 1 After routing the vent hose through and out the hole cutout, attach and secure the vent. 2 Airflow
BOOK INSTL DD24S PH7 US CA EN (English)
Page 2
... STANDARD HEIGHT SINGLE MODELS Designer Integrated Classic TALL HEIGHT SINGLE MODELS Designer Integrated DD24SCX7 DD24SCW7 DD24SCB7 DD24SDFX7 DD24SI7 DD24SCTX7 DD24SCHTX7 DD24SCTW7 DD24SCTB7 DD24SDFTX7 DD24STI7 DD24SHTI7 PARTS SUPPLIED PRODUCT & CABINETRY DIMENSIONS (STANDARD HEIGHT) OPTIONALLY HARD WIRING ...BY DRAWER REMOVAL DRAWER REMOVAL RECOMMENDED ALTERNATIVE METHOD (a) METHOD (b) FOLLOW STEPS FOR THE EXTERNAL VENTING KIT FOLLOW STEPS FOR THE EXTERNAL VENTING KIT INSTALL THE FRONT PANEL CHOOSE DRAINAGE OPTION CONNECT TO WATER & ELECTRICITY FINAL CHECKLIST TROUBLESHOOTING ...
... STANDARD HEIGHT SINGLE MODELS Designer Integrated Classic TALL HEIGHT SINGLE MODELS Designer Integrated DD24SCX7 DD24SCW7 DD24SCB7 DD24SDFX7 DD24SI7 DD24SCTX7 DD24SCHTX7 DD24SCTW7 DD24SCTB7 DD24SDFTX7 DD24STI7 DD24SHTI7 PARTS SUPPLIED PRODUCT & CABINETRY DIMENSIONS (STANDARD HEIGHT) OPTIONALLY HARD WIRING ...BY DRAWER REMOVAL DRAWER REMOVAL RECOMMENDED ALTERNATIVE METHOD (a) METHOD (b) FOLLOW STEPS FOR THE EXTERNAL VENTING KIT FOLLOW STEPS FOR THE EXTERNAL VENTING KIT INSTALL THE FRONT PANEL CHOOSE DRAINAGE OPTION CONNECT TO WATER & ELECTRICITY FINAL CHECKLIST TROUBLESHOOTING ...
BOOK INSTL DD24S PH7 US CA EN (English)
Page 5
3b ADDITIONAL PARTS SUPPLIED WITH INTEGRATED MODELS 5 External Venting kit (1) Panel bracket (1) (attached to product) Panel mounting screws (6)
3b ADDITIONAL PARTS SUPPLIED WITH INTEGRATED MODELS 5 External Venting kit (1) Panel bracket (1) (attached to product) Panel mounting screws (6)
BOOK INSTL DD24S PH7 US CA EN (English)
Page 8
... the first box below , then complete the equation. min. 1⁄16" (2mm) ventilation gap with external venting kit installed min. 1⁄16" (2mm) ventilation gap with the top of the panel is aligned with external venting kit installed clearance to withstand moisture (122OF/ 50OC @ 80% RH) Maximum weight of panel: 20 lb...
... the first box below , then complete the equation. min. 1⁄16" (2mm) ventilation gap with external venting kit installed min. 1⁄16" (2mm) ventilation gap with the top of the panel is aligned with external venting kit installed clearance to withstand moisture (122OF/ 50OC @ 80% RH) Maximum weight of panel: 20 lb...
BOOK INSTL DD24S PH7 US CA EN (English)
Page 11
... you fit the supplied Edge Protector around the hole for the hoses should be located either side of dishwasher VENT HOSE ø 2 3⁄8" (60 mm) ø max. 1½"(38 mm) Shelf cutouts External Venting kit (1) max. 3⁄16" (5 mm) ø 2 3⁄8" (60 mm) DRAIN HOSE + ...INLET HOSE + POWER CORD 8 11⁄16" (220 mm) 4" (100 mm) 9b INTEGRATED MODELS ONLY - PREPARATION FOR EXTERNAL VENTING THROUGH SAME CABINET 11 Services can be located either side of dishwasher ø 2 3⁄8" 60mm The ø 2 3⁄8" (60 mm) services hole for the ...
... you fit the supplied Edge Protector around the hole for the hoses should be located either side of dishwasher VENT HOSE ø 2 3⁄8" (60 mm) ø max. 1½"(38 mm) Shelf cutouts External Venting kit (1) max. 3⁄16" (5 mm) ø 2 3⁄8" (60 mm) DRAIN HOSE + ...INLET HOSE + POWER CORD 8 11⁄16" (220 mm) 4" (100 mm) 9b INTEGRATED MODELS ONLY - PREPARATION FOR EXTERNAL VENTING THROUGH SAME CABINET 11 Services can be located either side of dishwasher ø 2 3⁄8" 60mm The ø 2 3⁄8" (60 mm) services hole for the ...
BOOK INSTL DD24S PH7 US CA EN (English)
Page 12
10 MAXIMUM DISTANCE OF HOSES & CORD FROM CHASSIS EDGE 12 Left hand side Drain hose - 78 ½" (2000 mm) Inlet hose - 64 ¾" (1650 mm) Power cord (excl. plug) - 27 ½" (700 mm) Venting hose - 75 13⁄16" (1925 mm) (Integrated models only) plug) - 29 ½" (750 mm) Venting hose - 60 1⁄16" (1525 mm) (Integrated models only) Right hand side Drain hose - 70 ½" (1800 mm) Inlet hose - 49" (1250 mm) Power cord (excl.
10 MAXIMUM DISTANCE OF HOSES & CORD FROM CHASSIS EDGE 12 Left hand side Drain hose - 78 ½" (2000 mm) Inlet hose - 64 ¾" (1650 mm) Power cord (excl. plug) - 27 ½" (700 mm) Venting hose - 75 13⁄16" (1925 mm) (Integrated models only) plug) - 29 ½" (750 mm) Venting hose - 60 1⁄16" (1525 mm) (Integrated models only) Right hand side Drain hose - 70 ½" (1800 mm) Inlet hose - 49" (1250 mm) Power cord (excl.
BOOK INSTL DD24S PH7 US CA EN (English)
Page 14
Ensure they're securely fitted before sliding product into their slots A using a flat-bladed screwdriver. ATTACH VENTING HOSE Check that the fitted elbow is rotated left or right (depending on each side diagonally across the product. RECOMMENDED METHOD (a) - B A... A B A The mounting slots are in pairs, B one on the direction of the routing), then ensure the venting hose is securely attached to it. A bracket must match A slot and B bracket must match B slot. 13a INTEGRATED ONLY - 14 NOW CHOOSE WHICH INSTALLATION METHOD...
Ensure they're securely fitted before sliding product into their slots A using a flat-bladed screwdriver. ATTACH VENTING HOSE Check that the fitted elbow is rotated left or right (depending on each side diagonally across the product. RECOMMENDED METHOD (a) - B A... A B A The mounting slots are in pairs, B one on the direction of the routing), then ensure the venting hose is securely attached to it. A bracket must match A slot and B bracket must match B slot. 13a INTEGRATED ONLY - 14 NOW CHOOSE WHICH INSTALLATION METHOD...
BOOK INSTL DD24S PH7 US CA EN (English)
Page 15
... plug back into the trim moulding and ensure the trim seal is facing forward. 3 Repeat for all four brackets. 1 After routing the vent hose through the trim moulding, securing the side mounting bracket to incorrect operation. 16a INTEGRATED ONLY - Using a flat-bladed screwdriver, prize ... screwdriver, screw through and out the hole cutout, attach and secure the vent by tightening the four screws provided. 2 Airflow 14a PULL THROUGH HOSES & MOVE INTO THE CAVITY Vent Hose (Integrated models only) vent either through same cabinet or adjacent cabinet as doing so may squash the hoses...
... plug back into the trim moulding and ensure the trim seal is facing forward. 3 Repeat for all four brackets. 1 After routing the vent hose through the trim moulding, securing the side mounting bracket to incorrect operation. 16a INTEGRATED ONLY - Using a flat-bladed screwdriver, prize ... screwdriver, screw through and out the hole cutout, attach and secure the vent by tightening the four screws provided. 2 Airflow 14a PULL THROUGH HOSES & MOVE INTO THE CAVITY Vent Hose (Integrated models only) vent either through same cabinet or adjacent cabinet as doing so may squash the hoses...
BOOK INSTL DD24S PH7 US CA EN (English)
Page 16
... product in far enough, pull out again and rearrange hoses and cord. Important! Fitted Elbow 13b PULL THROUGH HOSES & MOVE INTO THE CAVITY Vent Hose (Integrated models only) vent either through hoses and cord, ensuring they don't get kinked or twisted. 16 ALTERNATIVE METHOD (b) - If product cannot be pushed in , pull ... same cabinet or adjacent cabinet as doing so may squash the hoses and lead to it. SECURE BY DRAWER REMOVAL 12b INTEGRATED ONLY - ATTACH VENTING HOSE Check that the fitted elbow is rotated left or right (depending on the direction of the routing), then ensure the...
... product in far enough, pull out again and rearrange hoses and cord. Important! Fitted Elbow 13b PULL THROUGH HOSES & MOVE INTO THE CAVITY Vent Hose (Integrated models only) vent either through hoses and cord, ensuring they don't get kinked or twisted. 16 ALTERNATIVE METHOD (b) - If product cannot be pushed in , pull ... same cabinet or adjacent cabinet as doing so may squash the hoses and lead to it. SECURE BY DRAWER REMOVAL 12b INTEGRATED ONLY - ATTACH VENTING HOSE Check that the fitted elbow is rotated left or right (depending on the direction of the routing), then ensure the...
BOOK INSTL DD24S PH7 US CA EN (English)
Page 17
14b REMOVE THE DRAWER 4 1 Product may move. SECURE THE EXTERNAL VENT 159 148 Ensure the release tabs on the bottom (use 5⁄8" (16 mm) screws) 1 2 a pair of each drawer runner are reset fully. Before refitting the ... and the latches at the rear of fixing holes on 115 both sides are facing forward. 126 1 After routing the vent hose through and out the hole cutout, attach and secure the vent by tightening the four screws provided. 2 Airflow two pairs of formed brackets on its side after removal. 5 Push drawer...
14b REMOVE THE DRAWER 4 1 Product may move. SECURE THE EXTERNAL VENT 159 148 Ensure the release tabs on the bottom (use 5⁄8" (16 mm) screws) 1 2 a pair of each drawer runner are reset fully. Before refitting the ... and the latches at the rear of fixing holes on 115 both sides are facing forward. 126 1 After routing the vent hose through and out the hole cutout, attach and secure the vent by tightening the four screws provided. 2 Airflow two pairs of formed brackets on its side after removal. 5 Push drawer...