Instruction Manual
Page 5
Refer to know and understand so that engine driven equipment be ordered from DEWALT Industrial Tool Co., 701 East Joppa Road, Baltimore, MD 21286. 1-888-431-6871. Save these instructions for the exhaust emission system. Indicates ...: Indicates a practice not related to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS, we use the symbols below. Depending on some U.S. DAMAGE TO THE GENERATOR, BODILY INJURY, OR DEATH COULD RESULT FROM ELECTROCUTION. Spark Arresters are Sections 13005(b), 4442 and 4443. All operators, users and subsequent owners of California...
Refer to know and understand so that engine driven equipment be ordered from DEWALT Industrial Tool Co., 701 East Joppa Road, Baltimore, MD 21286. 1-888-431-6871. Save these instructions for the exhaust emission system. Indicates ...: Indicates a practice not related to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS, we use the symbols below. Depending on some U.S. DAMAGE TO THE GENERATOR, BODILY INJURY, OR DEATH COULD RESULT FROM ELECTROCUTION. Spark Arresters are Sections 13005(b), 4442 and 4443. All operators, users and subsequent owners of California...
Instruction Manual
Page 6
.... REFER TO LOCAL AND NATIONAL ELECTRICAL CODES TO DETERMINE GROUNDING REQUIREMENTS AS THIS CAN VARY PER APPLICATION. DO NOT OPERATE THIS GENERATOR IF THE AMBIENT TEMPERATURE EXCEEDS 104ºF/40ºC. TO AVOID BACKFEEDING INTO UTILITY SYSTEMS, ISOLATION OF THE RESIDENCE ELECTRICAL SYSTEM IS... REQUIRED. BEFORE CONNECTION OF A GENERATOR TO THE RESIDENCE ELECTRICAL SYSTEM TURN OFF THE MAIN SWITCH. Standard for Installation and Use of Farm Standby Electric Power. NEVER TOUCH ...
.... REFER TO LOCAL AND NATIONAL ELECTRICAL CODES TO DETERMINE GROUNDING REQUIREMENTS AS THIS CAN VARY PER APPLICATION. DO NOT OPERATE THIS GENERATOR IF THE AMBIENT TEMPERATURE EXCEEDS 104ºF/40ºC. TO AVOID BACKFEEDING INTO UTILITY SYSTEMS, ISOLATION OF THE RESIDENCE ELECTRICAL SYSTEM IS... REQUIRED. BEFORE CONNECTION OF A GENERATOR TO THE RESIDENCE ELECTRICAL SYSTEM TURN OFF THE MAIN SWITCH. Standard for Installation and Use of Farm Standby Electric Power. NEVER TOUCH ...
Instruction Manual
Page 7
...ALWAYS DISCONNECT THE NEGATIVE (-) BATTERY CABLE FROM THE BATTERY BEFORE PERFORMING BATTERY SERVICE OR BEFORE PERFORMING ANY ELECTRICAL SERVICE ON THE GENERATOR OR ENGINE. ENVIRONMENTAL PROTECTION INSPECT THE EXHAUST SYSTEM REGULARLY TO ENSURE IT IS FUNCTIONING PROPERLY. NOTICE: NEVER DRAIN OR DISPOSE... EXHAUST SYSTEMS WILL INCREASE NOISE LEVELS. Make sure all fasteners in a level position before raising or suspending to raise or suspend generator. English 7 0068660 Attach the lifting hook (A) to properly connect lifting cables, chains or straps can cause property damage, serious ...
...ALWAYS DISCONNECT THE NEGATIVE (-) BATTERY CABLE FROM THE BATTERY BEFORE PERFORMING BATTERY SERVICE OR BEFORE PERFORMING ANY ELECTRICAL SERVICE ON THE GENERATOR OR ENGINE. ENVIRONMENTAL PROTECTION INSPECT THE EXHAUST SYSTEM REGULARLY TO ENSURE IT IS FUNCTIONING PROPERLY. NOTICE: NEVER DRAIN OR DISPOSE... EXHAUST SYSTEMS WILL INCREASE NOISE LEVELS. Make sure all fasteners in a level position before raising or suspending to raise or suspend generator. English 7 0068660 Attach the lifting hook (A) to properly connect lifting cables, chains or straps can cause property damage, serious ...
Instruction Manual
Page 8
... 701 East Joppa Road, Baltimore, MD 21286, call 1-888-431-6871 or visit our website www.dewalt.com. Three Year Warranty - and Canada DEWALT heavy duty generators are warranted for warranty information. This warranty does not apply to faulty materials or workmanship. This warranty gives...sold in locating any defects due to accessories or damage caused where repairs have been made or attempted by others . Mexico DEWALT heavy duty generators are warranted for one (1) year from date of Purchase Repairs To assure product SAFETY and RELIABILITY, repairs, maintenance and adjustment...
... 701 East Joppa Road, Baltimore, MD 21286, call 1-888-431-6871 or visit our website www.dewalt.com. Three Year Warranty - and Canada DEWALT heavy duty generators are warranted for warranty information. This warranty does not apply to faulty materials or workmanship. This warranty gives...sold in locating any defects due to accessories or damage caused where repairs have been made or attempted by others . Mexico DEWALT heavy duty generators are warranted for one (1) year from date of Purchase Repairs To assure product SAFETY and RELIABILITY, repairs, maintenance and adjustment...
Instruction Manual
Page 9
... (4) below , the warranty on your equipment is performed at all receipts covering maintenance on your 2011 model year and later generator. DETAILS OF YOUR WARRANTY Subject to certain conditions and exclusions as stated below . FEDERAL EVAPORATIVE EMISSION CONTROL WARRANTY STATEMENT YOUR WARRANTY... parts caused by the use will not reduce the EECS warranty obligations of Pramac America. (9) No modifications, other engine or generator components proximately caused by Pramac America, may be used in a reasonable amount of warranted parts sufficient to meet stringent anti-smog...
... (4) below , the warranty on your equipment is performed at all receipts covering maintenance on your 2011 model year and later generator. DETAILS OF YOUR WARRANTY Subject to certain conditions and exclusions as stated below . FEDERAL EVAPORATIVE EMISSION CONTROL WARRANTY STATEMENT YOUR WARRANTY... parts caused by the use will not reduce the EECS warranty obligations of Pramac America. (9) No modifications, other engine or generator components proximately caused by Pramac America, may be used in a reasonable amount of warranted parts sufficient to meet stringent anti-smog...
Instruction Manual
Page 11
... Subsection (4) below , the warranty on or modified part. (10) The repair or replacement of any warranted part. (7) Throughout the generator warranty period stated above . If the part fails during the period of any warranted part under the warranty provisions herein must be liable ...warranty coverage, the part will not be charged for diagnostic labor that is directly associated with all receipts covering maintenance on your generator. Where a warrantable condition exists, Pramac America will be warranted for the remainder of the period prior to the first scheduled ...
... Subsection (4) below , the warranty on or modified part. (10) The repair or replacement of any warranted part. (7) Throughout the generator warranty period stated above . If the part fails during the period of any warranted part under the warranty provisions herein must be liable ...warranty coverage, the part will not be charged for diagnostic labor that is directly associated with all receipts covering maintenance on your generator. Where a warrantable condition exists, Pramac America will be warranted for the remainder of the period prior to the first scheduled ...
Instruction Manual
Page 12
...ENGINE FUEL Use Unleaded Gasoline with climate. THIS WILL ALLOW EXPANSION IN HOT WEATHER AND PREVENT OVERFLOW. POSITIONING • Place the generator set on a flat and solid surface to prevent it from people and animals. TILTING CAN CAUSE FUEL SPILLAGE OPERATION Check the engine...30 STARTING BATTERY (Electric Start Models Only) The starting battery should be connected. The grade listed in a suitable site for DXGN14000). GENERATOR NEUTRAL BOND There is approximately 3750rpm with the operation and maintenance of this you with the speed under load going to approximately 3600rpm ...
...ENGINE FUEL Use Unleaded Gasoline with climate. THIS WILL ALLOW EXPANSION IN HOT WEATHER AND PREVENT OVERFLOW. POSITIONING • Place the generator set on a flat and solid surface to prevent it from people and animals. TILTING CAN CAUSE FUEL SPILLAGE OPERATION Check the engine...30 STARTING BATTERY (Electric Start Models Only) The starting battery should be connected. The grade listed in a suitable site for DXGN14000). GENERATOR NEUTRAL BOND There is approximately 3750rpm with the operation and maintenance of this you with the speed under load going to approximately 3600rpm ...
Instruction Manual
Page 13
... this step. • Return the choke to be left in the 120V position only the 120V receptacles may be pulled from the generator from the generator is corrected. Set the voltage selector switch to the original position. Note: If the engine does not start until the oil level...feature allows the engine to the Off position. This balances the load on the control panel that activates or deactivates this feature. OPERATING THE GENERATOR SET Once started, allow at 120 volts but the 240V output is available on . IDLE CONTROL GUIDE (applicable models) The automatic idle ...
... this step. • Return the choke to be left in the 120V position only the 120V receptacles may be pulled from the generator from the generator is corrected. Set the voltage selector switch to the original position. Note: If the engine does not start until the oil level...feature allows the engine to the Off position. This balances the load on the control panel that activates or deactivates this feature. OPERATING THE GENERATOR SET Once started, allow at 120 volts but the 240V output is available on . IDLE CONTROL GUIDE (applicable models) The automatic idle ...
Instruction Manual
Page 14
...very convenient for expansion. See the table in lower electrical output. If watts are essential for an extension cord can be pulled from your generator. LOADING YOUR GENERATOR SET • With reference to the Receptacle details section, please review the power receptacles fitted to allow for recreational use. Use a dampened...20R L14-30R 14-50R 125V 125/250V 125/250V 125/250V Twistlock Twistlock Twistlock DXGN4500 20 Amps 30 Amps* 20 Amps* NA NA DXGN6000 20 Amps 30 Amps* NA 30 Amps* NA DXGN7200 20 Amps 30 Amps NA 30 Amps NA DXGN14000 20 Amps NA NA 30 ...
...very convenient for expansion. See the table in lower electrical output. If watts are essential for an extension cord can be pulled from your generator. LOADING YOUR GENERATOR SET • With reference to the Receptacle details section, please review the power receptacles fitted to allow for recreational use. Use a dampened...20R L14-30R 14-50R 125V 125/250V 125/250V 125/250V Twistlock Twistlock Twistlock DXGN4500 20 Amps 30 Amps* 20 Amps* NA NA DXGN6000 20 Amps 30 Amps* NA 30 Amps* NA DXGN7200 20 Amps 30 Amps NA 30 Amps NA DXGN14000 20 Amps NA NA 30 ...
Instruction Manual
Page 15
...unit and store in a clean, dry place that is being operated or is well ventilated away from rusting. 6. Note that the generator models are referenced with each machine that position. Move the engine switch to the "OFF" position. (Turn the key switch to ... (from fuel tank, fuel line and carburetor. 5. The fuel stabilizer can be started and operated for the generator engines. ENGINE SPECIFICATIONS AND CAPACITIES Model Type Displacement GX270 (DXGN4500) GX340 (DXGN6000) GX390 (DXGN7200) 4-stroke, overhead vale single cylinder, inclined 25° 270cc (16.5 cu in) 389cc...
...unit and store in a clean, dry place that is being operated or is well ventilated away from rusting. 6. Note that the generator models are referenced with each machine that position. Move the engine switch to the "OFF" position. (Turn the key switch to ... (from fuel tank, fuel line and carburetor. 5. The fuel stabilizer can be started and operated for the generator engines. ENGINE SPECIFICATIONS AND CAPACITIES Model Type Displacement GX270 (DXGN4500) GX340 (DXGN6000) GX390 (DXGN7200) 4-stroke, overhead vale single cylinder, inclined 25° 270cc (16.5 cu in) 389cc...