Instruction Manual
Page 2
Pressure Regulator E. Air Tank Drain Valve I. Pressure Switch K. Air Tank Pressure Gauge o C. Regulated Pressure Gauge D. Check Valve G. Motor Reset N. Safety Valve H. Handle Locking Knobs Q. On/Off Switch B. Handle P. English Air Compressor Fig. 1 A. NOT A STEP q B D C g i j n a p E K h M F L Quick Connects F. Air Intake Filter O. Pump Oil Dipstick L. Pump Oil Drain Plug M. Power Cord Wrap J. Top Panel for Cargo IMPORTANT: Always pull handle up and lock in place before using as a dolly.
Pressure Regulator E. Air Tank Drain Valve I. Pressure Switch K. Air Tank Pressure Gauge o C. Regulated Pressure Gauge D. Check Valve G. Motor Reset N. Safety Valve H. Handle Locking Knobs Q. On/Off Switch B. Handle P. English Air Compressor Fig. 1 A. NOT A STEP q B D C g i j n a p E K h M F L Quick Connects F. Air Intake Filter O. Pump Oil Dipstick L. Pump Oil Drain Plug M. Power Cord Wrap J. Top Panel for Cargo IMPORTANT: Always pull handle up and lock in place before using as a dolly.
Instruction Manual
Page 4
...such tools. Save these exposures varies, depending on how often you read the manual and pay attention to prevent it • Always operate the compressor in death or serious injury. DANGER: Indicates an imminently hazardous situation which , if not avoided, may result in minor or moderate injury. ... read and understand this type of explosion or fire IF YOU HAVE ANY QUESTIONS OR COMMENTS ABOUT THIS OR ANY DeWALT TOOL, CALL US TOLL FREE AT: 1-800-4-DeWALT (1-800-433-9258) Important Safety Instructions WARNING: Do not operate this unit until you do this instruction manual for...
...such tools. Save these exposures varies, depending on how often you read the manual and pay attention to prevent it • Always operate the compressor in death or serious injury. DANGER: Indicates an imminently hazardous situation which , if not avoided, may result in minor or moderate injury. ... read and understand this type of explosion or fire IF YOU HAVE ANY QUESTIONS OR COMMENTS ABOUT THIS OR ANY DeWALT TOOL, CALL US TOLL FREE AT: 1-800-4-DeWALT (1-800-433-9258) Important Safety Instructions WARNING: Do not operate this unit until you do this instruction manual for...
Instruction Manual
Page 5
...weed killers, may contain carbon monoxide, toxic vapors, or solid particles from any wall or obstruction that would restrict the flow of this compressor for breathing, suitable filters and in-line safety equipment must be properly installed. In-line filters and safety equipment used to prevent it ... product when it • Air obtained directly from your specific application. Do not operate unit indoors or in any of the compressor ventilation openings will cause serious overheating and could result in personal injury or property damage. How to supply air for the materials you ...
...weed killers, may contain carbon monoxide, toxic vapors, or solid particles from any wall or obstruction that would restrict the flow of this compressor for breathing, suitable filters and in-line safety equipment must be properly installed. In-line filters and safety equipment used to prevent it ... product when it • Air obtained directly from your specific application. Do not operate unit indoors or in any of the compressor ventilation openings will cause serious overheating and could result in personal injury or property damage. How to supply air for the materials you ...
Instruction Manual
Page 6
... factory set operating pressures. • Follow the equipment manufacturers recommendation and never exceed the maximum allowable pressure rating of attachments. Remove compressor from vehicle immediately upon arrival at your state pressure vessels inspector, look under the Division of Labor and Industries in the government section... of a phone book or call 1-800-4-DeWALT for units with a new air tank. • The air tank is designed and may be inspected once every two years. The...
... factory set operating pressures. • Follow the equipment manufacturers recommendation and never exceed the maximum allowable pressure rating of attachments. Remove compressor from vehicle immediately upon arrival at your state pressure vessels inspector, look under the Division of Labor and Industries in the government section... of a phone book or call 1-800-4-DeWALT for units with a new air tank. • The air tank is designed and may be inspected once every two years. The...
Instruction Manual
Page 7
... death by electrocution. • Electrical Grounding: Failure to provide adequate grounding to this product should be performed by a DeWALT factory service center or a DeWALT authorized service center in accordance with side shields when using the compressor. • Never point any nozzle or sprayer toward any other people or animals. How to prevent it...
... death by electrocution. • Electrical Grounding: Failure to provide adequate grounding to this product should be performed by a DeWALT factory service center or a DeWALT authorized service center in accordance with side shields when using the compressor. • Never point any nozzle or sprayer toward any other people or animals. How to prevent it...
Instruction Manual
Page 8
... into contact with you or your hair, clothing, and gloves away from the air hose and air tank before attempting maintenance, attaching tools or accessories. Compressor will remain hot for several minutes after operation. WARNING: RISK OF Hot surfaces What can happen How to prevent it • Moving parts such as... cool. Loose clothes, jewelry, or long hair can be caught in moving parts. • Air vents may cover moving parts and should be performed by a DeWALT factory service center or a DeWALT authorized service center.
... into contact with you or your hair, clothing, and gloves away from the air hose and air tank before attempting maintenance, attaching tools or accessories. Compressor will remain hot for several minutes after operation. WARNING: RISK OF Hot surfaces What can happen How to prevent it • Moving parts such as... cool. Loose clothes, jewelry, or long hair can be caught in moving parts. • Air vents may cover moving parts and should be performed by a DeWALT factory service center or a DeWALT authorized service center.
Instruction Manual
Page 9
... ous in a stable secure position to prevent accidental movement of the unit. WARNING: RISK OF FALLING What can happen How to prevent it • A portable compressor can fall from others . • Become familiar with missing, broken, or unautho rized parts... operation with a fire extinguisher. • Do not operate machine with the operation and controls of the air compressor. • Keep operating area clear of all persons, pets, and obstacles. • Keep children away from attempting to lift too heavy an ...
... ous in a stable secure position to prevent accidental movement of the unit. WARNING: RISK OF FALLING What can happen How to prevent it • A portable compressor can fall from others . • Become familiar with missing, broken, or unautho rized parts... operation with a fire extinguisher. • Do not operate machine with the operation and controls of the air compressor. • Keep operating area clear of all persons, pets, and obstacles. • Keep children away from attempting to lift too heavy an ...
Instruction Manual
Page 10
...to prevent it • Under some conditions and duration of quick connect plugs: Industrial, automotive, and ARO. G Check Valve When the air compressor is operating, the check valve (F) is always less than the pressure switch cut - Pressure Switch A The pressure switch (J) automatically starts the motor... when the air tank pres- Safety Valve If the pressure switch does not shut off the air compressor at its factory set cut -in B the tank. Regulator The regulator (D) controls the air pressure shown on the outlet pressure gauge. When...
...to prevent it • Under some conditions and duration of quick connect plugs: Industrial, automotive, and ARO. G Check Valve When the air compressor is operating, the check valve (F) is always less than the pressure switch cut - Pressure Switch A The pressure switch (J) automatically starts the motor... when the air tank pres- Safety Valve If the pressure switch does not shut off the air compressor at its factory set cut -in B the tank. Regulator The regulator (D) controls the air pressure shown on the outlet pressure gauge. When...
Instruction Manual
Page 11
... Protector This motor has a manual thermal overload protector. K 2. Depress the reset button (M) on top panel (Q). 2. Check pump oil daily, see Compressor Pump Oil under Maintenance. Avoid placing hands between handle and top panel when assembling to cool. 3. Installing Hoses Warning: Risk of personal injury. Firmly grasp... the amount M of each use. Grasp the hose and pull to ensure coupler is designed to cool down until the compressor has raised the air tank pressure above that required at the end of oil in large amounts. H Cooling System This...
... Protector This motor has a manual thermal overload protector. K 2. Depress the reset button (M) on top panel (Q). 2. Check pump oil daily, see Compressor Pump Oil under Maintenance. Avoid placing hands between handle and top panel when assembling to cool. 3. Installing Hoses Warning: Risk of personal injury. Firmly grasp... the amount M of each use. Grasp the hose and pull to ensure coupler is designed to cool down until the compressor has raised the air tank pressure above that required at the end of oil in large amounts. H Cooling System This...
Instruction Manual
Page 12
... not be used must be installed by a qualified electrician. Repairs to the cord set and plug (R) with oil will cause premature compressor failure. Pull coupler on hose. Do not attempt to the crankcase. NOTE: See Specifications for the electric current. Replace dipstick. The... reads 0 PSI (0 kPa). 2. Closely follow Initial Set-up under Operation. Remove dipstick (K) and slowly add K DeWalt synthetic oil (supplied). Overfilling with this air compressor without oil in doubt as the grounded plug. T IMPORTANT: The outlet being used with all local codes and ordinances....
... not be used must be installed by a qualified electrician. Repairs to the cord set and plug (R) with oil will cause premature compressor failure. Pull coupler on hose. Do not attempt to the crankcase. NOTE: See Specifications for the electric current. Replace dipstick. The... reads 0 PSI (0 kPa). 2. Closely follow Initial Set-up under Operation. Remove dipstick (K) and slowly add K DeWalt synthetic oil (supplied). Overfilling with this air compressor without oil in doubt as the grounded plug. T IMPORTANT: The outlet being used with all local codes and ordinances....
Instruction Manual
Page 13
...interfere with the flow of hose to the Voltage and Minimum Branch Circuit Requirements under Specifications. Contact a DeWALT service center or call 1-800-4-DeWALT for information regarding acceptable noise levels in compressed air is equipped with petroleum-based products. English Extension Cords ...that a material is not compatible with the National Electrical Code. • Circuit is connected to change the cord set. NOTE: If compressor is not used . It is not recommended. NOTE: Always use vibration mounts or silencers, relocate the unit or construct total enclosures or...
...interfere with the flow of hose to the Voltage and Minimum Branch Circuit Requirements under Specifications. Contact a DeWALT service center or call 1-800-4-DeWALT for information regarding acceptable noise levels in compressed air is equipped with petroleum-based products. English Extension Cords ...that a material is not compatible with the National Electrical Code. • Circuit is connected to change the cord set. NOTE: If compressor is not used . It is not recommended. NOTE: Always use vibration mounts or silencers, relocate the unit or construct total enclosures or...
Instruction Manual
Page 14
...of unsafe operation. NOTE: Should the unit tip over in top panel. Place cargo onto top panel of unsafe operation. CAUTION: Risk of compressor. 3. Warning: Risk of sizes. Ensure the On/Off switch (A) is secured and placed on the tires. English Electrical Refer to all ...safety instructions before using as a dolly. 2. TRANSPORTING When transporting the compressor in a horizontal position. Use care when driving so to avoid tipping the unit over , hard starting and smoking will occur due to oil ...
...of unsafe operation. NOTE: Should the unit tip over in top panel. Place cargo onto top panel of unsafe operation. CAUTION: Risk of compressor. 3. Warning: Risk of sizes. Ensure the On/Off switch (A) is secured and placed on the tires. English Electrical Refer to all ...safety instructions before using as a dolly. 2. TRANSPORTING When transporting the compressor in a horizontal position. Use care when driving so to avoid tipping the unit over , hard starting and smoking will occur due to oil ...
Instruction Manual
Page 15
... (D) to the ON position and allow tank pres- NOTE: If hose is not responsible for safety, operation and maintenance instructions. DeWALT escape and prevent air pressure build up (Fig. 1) hazardous risk of bursting. Warning: Risk of property damage. After 20 minutes... Check the manufacturer's maximum 1. pressure must never exceed the maximum pressure rating. This procedure is required before the air compressor is drained, see Compressor Pump Oil under Voltage and Circuit Protection under Installation. Check pump oil level, see Draining Air Tank under Maintenance. ...
... (D) to the ON position and allow tank pres- NOTE: If hose is not responsible for safety, operation and maintenance instructions. DeWALT escape and prevent air pressure build up (Fig. 1) hazardous risk of bursting. Warning: Risk of property damage. After 20 minutes... Check the manufacturer's maximum 1. pressure must never exceed the maximum pressure rating. This procedure is required before the air compressor is drained, see Compressor Pump Oil under Voltage and Circuit Protection under Installation. Check pump oil level, see Draining Air Tank under Maintenance. ...
Instruction Manual
Page 16
...out, look for air bubbles to cool down before starting service. Remove air compressor plug from outlet. 3. Clean compressor exterior X * To check for air leaks* X 2. NOTE: If finished using DeWALT synthetic compressor oil, change oil every 200 hours of air tank rupture. Water will ...or once a year, whichever comes first. + Perform more frequent in air tank. Allow the compressor to form. ** The pump oil must be performed by a DeWALT factory service center or a DeWALT authorized service center. Check for air leaks apply a solution of in accordance with local, state...
...out, look for air bubbles to cool down before starting service. Remove air compressor plug from outlet. 3. Clean compressor exterior X * To check for air leaks* X 2. NOTE: If finished using DeWALT synthetic compressor oil, change oil every 200 hours of air tank rupture. Water will ...or once a year, whichever comes first. + Perform more frequent in air tank. Allow the compressor to form. ** The pump oil must be performed by a DeWALT factory service center or a DeWALT authorized service center. Check for air leaks apply a solution of in accordance with local, state...
Instruction Manual
Page 17
...drained, water will condense in the OFF position. 2. When air tank pressure gauge reads 10 PSI (68,9 kPa), rotate valve to servicing. 1. Allow compressor to cool prior to the fully open position. 7. Remove dipstick (K) and wipe clean. 17 Checking Air Filter Element (Fig. 1) Warning: Hot surfaces...If element needs cleaning, blow out with the same type of bursting. CAUTION: Risk of burn. Risk of unsafe operation. Before starting compressor, pull the ring on the safety valve to unit. NOTE: All compressed air systems generate condensate that the safety valve operates freely....
...drained, water will condense in the OFF position. 2. When air tank pressure gauge reads 10 PSI (68,9 kPa), rotate valve to servicing. 1. Allow compressor to cool prior to the fully open position. 7. Remove dipstick (K) and wipe clean. 17 Checking Air Filter Element (Fig. 1) Warning: Hot surfaces...If element needs cleaning, blow out with the same type of bursting. CAUTION: Risk of burn. Risk of unsafe operation. Before starting compressor, pull the ring on the safety valve to unit. NOTE: All compressed air systems generate condensate that the safety valve operates freely....
Instruction Manual
Page 18
... with this tool could be performed by a DeWALT factory service center, a DeWALT authorized service center or other accessory not recommended for all oil to be disposed of the air compressor. CAUTION: The use with your tool, please contact DeWALT Industrial Tool Co., 701 East Joppa Road, ...Aftercooler, MIN pump head, and surrounding parts are regulated and must be full. Allow compressor to cool prior to read oil level. Ensure On/Off switch is in accordance with DeWALT synthetic compressor oil. 11. Drain air tank. 5. MAX Warning: Hot surfaces. Install the oil ...
... with this tool could be performed by a DeWALT factory service center, a DeWALT authorized service center or other accessory not recommended for all oil to be disposed of the air compressor. CAUTION: The use with your tool, please contact DeWALT Industrial Tool Co., 701 East Joppa Road, ...Aftercooler, MIN pump head, and surrounding parts are regulated and must be full. Allow compressor to cool prior to read oil level. Ensure On/Off switch is in accordance with DeWALT synthetic compressor oil. 11. Drain air tank. 5. MAX Warning: Hot surfaces. Install the oil ...
Instruction Manual
Page 19
...-45 minutes in Latin America. English Full One Year Warranty DeWalt heavy duty industrial tools are missing, call 1-800-4-DeWALT for a free replacement. Latin America: This warranty does not apply to build. PSI: Pounds per minute; Cut-Out Pressure: When an air compressor is recommended that a 50%-75% average duty cycle be maintained...
...-45 minutes in Latin America. English Full One Year Warranty DeWalt heavy duty industrial tools are missing, call 1-800-4-DeWALT for a free replacement. Latin America: This warranty does not apply to build. PSI: Pounds per minute; Cut-Out Pressure: When an air compressor is recommended that a 50%-75% average duty cycle be maintained...
Instruction Manual
Page 20
... and valve plate 5 Air leaks from safety valve...6 Knocking Noise...6,16,17 Pressure reading on the regulated pressure gauge drops when an accessory is used 7 Compressor is not supplying enough air to operate accessories 8,9,10,11,12,15 Regulator knob has continuous air leak 13 Regulator will not shut off air......14,18 Motor will not run...11,19,20,21,22,23,24,25,26 20 English Troubleshooting Guide This section provides a list of a qualified DeWalt technician or your dealer.
... and valve plate 5 Air leaks from safety valve...6 Knocking Noise...6,16,17 Pressure reading on the regulated pressure gauge drops when an accessory is used 7 Compressor is not supplying enough air to operate accessories 8,9,10,11,12,15 Regulator knob has continuous air leak 13 Regulator will not shut off air......14,18 Motor will not run...11,19,20,21,22,23,24,25,26 20 English Troubleshooting Guide This section provides a list of a qualified DeWalt technician or your dealer.
Instruction Manual
Page 21
... OFF, if the unit does not shut reaches cut -out too high Contact a DeWALT factory service center or a DeWALT authorized service center. English Code 1 2 3 4 5 6 7 8 Troubleshooting Codes possible cause POSSIBLE SOLUTION Pressure switch does not shut off motor when compressor Set the On/Off switch to occur when an accessory is used, adjust the...
... OFF, if the unit does not shut reaches cut -out too high Contact a DeWALT factory service center or a DeWALT authorized service center. English Code 1 2 3 4 5 6 7 8 Troubleshooting Codes possible cause POSSIBLE SOLUTION Pressure switch does not shut off motor when compressor Set the On/Off switch to occur when an accessory is used, adjust the...
Instruction Manual
Page 22
... wire and cord length. Replace air hose. Replace. Contact a DeWALT factory service center or a DeWALT authorized service center. Drain oil and refill pump with DeWALT synthetic compressor oil. Contact a DeWALT factory service center or a DeWALT authorized service center. Remove, clean or replace. See Extension Cords ... Move unit to a dry well ventilated area Clean or replace air intake filter Add DeWALT synthetic compressor oil to operate accessory. English Code possible cause 9 Compressor is not large enough for accessory 10 Hole in air hose 11 Check valve restricted ...
... wire and cord length. Replace air hose. Replace. Contact a DeWALT factory service center or a DeWALT authorized service center. Drain oil and refill pump with DeWALT synthetic compressor oil. Contact a DeWALT factory service center or a DeWALT authorized service center. Remove, clean or replace. See Extension Cords ... Move unit to a dry well ventilated area Clean or replace air intake filter Add DeWALT synthetic compressor oil to operate accessory. English Code possible cause 9 Compressor is not large enough for accessory 10 Hole in air hose 11 Check valve restricted ...