Hardware Reference
Page 7
... 1-6 1-6 Disk enclosure front bezel 1-7 1-7 LCC connectors and status LEDs 1-8 1-8 Disk modules 1-10 1-9 Power/cooling module LEDs 1-12 2-1 Plugging in the AC line cords 2-5 2-2 Connecting DAE2P power cords (CX300/CX500 storage system) ........ 2-7 2-3 Connecting DAE3P power cords (CX3-80 storage system 2-8 2-4 Setting the enclosure address (EA 2-11 2-5 Connecting a disk enclosure to another FC device...
... 1-6 1-6 Disk enclosure front bezel 1-7 1-7 LCC connectors and status LEDs 1-8 1-8 Disk modules 1-10 1-9 Power/cooling module LEDs 1-12 2-1 Plugging in the AC line cords 2-5 2-2 Connecting DAE2P power cords (CX300/CX500 storage system) ........ 2-7 2-3 Connecting DAE3P power cords (CX3-80 storage system 2-8 2-4 Setting the enclosure address (EA 2-11 2-5 Connecting a disk enclosure to another FC device...
Hardware Reference
Page 35
... Figure 2-2 shows the power cord connections for enclosure power. EXP PRI !! DAE2P EXP PRI ! An integrated disk-and-processor enclosure, such as a CX300 or CX500-series DPE2, is always the first disk enclosure on the first bus (0,0). Power Cord Master Switch Power/ Cooling Module ... the first disk enclosure in a DPE2 configuration to a Standby Power Supply (SPS) for a typical CX300- SPS B SPS A ON I O OFF ON I O OFF ON I O OFF !! Figure 2-2 EMC3207 Connecting DAE2P power cords (CX300/CX500 storage system) b. You should not connect any DAE in a storage system (EA 0, bus ...
... Figure 2-2 shows the power cord connections for enclosure power. EXP PRI !! DAE2P EXP PRI ! An integrated disk-and-processor enclosure, such as a CX300 or CX500-series DPE2, is always the first disk enclosure on the first bus (0,0). Power Cord Master Switch Power/ Cooling Module ... the first disk enclosure in a DPE2 configuration to a Standby Power Supply (SPS) for a typical CX300- SPS B SPS A ON I O OFF ON I O OFF ON I O OFF !! Figure 2-2 EMC3207 Connecting DAE2P power cords (CX300/CX500 storage system) b. You should not connect any DAE in a storage system (EA 0, bus ...
Hardware Reference
Page 38
... unless the bus speed is set the EA with the rest of the system; Installing a DAE2P/DAE3P Setting the enclosure address Before you specify an enclosure address or connect your DAE2P/DAE3P to a back end bus, make certain the loop (bus) and EA are in ... enclosures as evenly as possible across the buses. 2-10 DAE2P/DAE3P Hardware Reference enclosure 2 includes 30-44, and so on separate buses (loops) from 0 through eight enclosures. For example, configure DAE2Ps on through 7 (valid addresses for CX300 and CX500 systems are contiguous throughout an array: enclosure ...
... unless the bus speed is set the EA with the rest of the system; Installing a DAE2P/DAE3P Setting the enclosure address Before you specify an enclosure address or connect your DAE2P/DAE3P to a back end bus, make certain the loop (bus) and EA are in ... enclosures as evenly as possible across the buses. 2-10 DAE2P/DAE3P Hardware Reference enclosure 2 includes 30-44, and so on separate buses (loops) from 0 through eight enclosures. For example, configure DAE2Ps on through 7 (valid addresses for CX300 and CX500 systems are contiguous throughout an array: enclosure ...