HP UPS Best Practices
Page 1
... Models...8 HP R1500 G2 Rackmount UPS 8 HP R3000 Rackmount UPS ...8 HP R/T3000 Rackmount UPS 9 HP R5500 Rackmount UPS ...10 HP Three-phase Rack-mountable UPS 11 HP Tower UPS Advantages...12 HP Tower UPS Models ...13 HP T750 G2 UPS...13 HP T1000 G3 and T1500 G3 UPSs 13 HP T750...
... Models...8 HP R1500 G2 Rackmount UPS 8 HP R3000 Rackmount UPS ...8 HP R/T3000 Rackmount UPS 9 HP R5500 Rackmount UPS ...10 HP Three-phase Rack-mountable UPS 11 HP Tower UPS Advantages...12 HP Tower UPS Models ...13 HP T750 G2 UPS...13 HP T1000 G3 and T1500 G3 UPSs 13 HP T750...
HP UPS Best Practices
Page 11
...-phase UPS line features twice the power density of their data centers, as it can expand from the RP36KW model to a 60kVA/60kW n+1 configuration) Page 11 of 27 The HP three-phase UPS line is available in several models to accommodate varied application needs and expanding IT environments, including: ● 8kVA...
...-phase UPS line features twice the power density of their data centers, as it can expand from the RP36KW model to a 60kVA/60kW n+1 configuration) Page 11 of 27 The HP three-phase UPS line is available in several models to accommodate varied application needs and expanding IT environments, including: ● 8kVA...
HP UPS Best Practices
Page 16
... Rack Height Three Phase Modular 8.6 kVA PDU AF432A R8000/3 INTL AF504A AF513A AF508A Three Phase Monitored 8.6 kVA Single Input Full Rack Height Three Phase Modular 11 kVA PDU Three Phase Monitored 11 kVA Single Input Full Rack Height Page 16 of 27
... Rack Height Three Phase Modular 8.6 kVA PDU AF432A R8000/3 INTL AF504A AF513A AF508A Three Phase Monitored 8.6 kVA Single Input Full Rack Height Three Phase Modular 11 kVA PDU Three Phase Monitored 11 kVA Single Input Full Rack Height Page 16 of 27
HP UPS Best Practices
Page 17
... Phase Monitored 8.6 kVA Single Input Full Rack Height Three Phase Monitored 17.3 kVA Dual Input Full Rack Height Three Phase Modular 11 kVA PDU Three Phase Monitored 11 kVA Single Input Full Rack Height Three Phase Monitored 22.1 kVA Dual Input Full Rack Height Three Phase Modular 8.6 kVA PDU ...Three Phase Monitored 8.6 kVA Single Input Full Rack Height Three Phase Modular 11 kVA PDU Three Phase Monitored 11 kVA Single Input Full Rack Height Three Phase Monitored 22.1 kVA Dual Input Full Rack Height UPS Model UPS Description Number AF446A...
... Phase Monitored 8.6 kVA Single Input Full Rack Height Three Phase Monitored 17.3 kVA Dual Input Full Rack Height Three Phase Modular 11 kVA PDU Three Phase Monitored 11 kVA Single Input Full Rack Height Three Phase Monitored 22.1 kVA Dual Input Full Rack Height Three Phase Modular 8.6 kVA PDU ...Three Phase Monitored 8.6 kVA Single Input Full Rack Height Three Phase Modular 11 kVA PDU Three Phase Monitored 11 kVA Single Input Full Rack Height Three Phase Monitored 22.1 kVA Dual Input Full Rack Height UPS Model UPS Description Number AF446A...
Updating Firmware via USB to Serial Connection
Page 1
... to select low (1). 12. The Advanced Settings screen appears. 10. Click the Hardware tab. 4. Click Restore Defaults. Click YES. See "Reassigning the USB COM ports." 11.
... to select low (1). 12. The Advanced Settings screen appears. 10. Click the Hardware tab. 4. Click Restore Defaults. Click YES. See "Reassigning the USB COM ports." 11.
Increasing energy efficiency with modular HP three-phase power distribution
Page 1
... three-phase UPSs 7 Three-phase power distribution technology 8 Load balancing and monitoring ...8 Cable reduction ...9 HP solutions: PDR and pre-configured distribution cables 10 Configuration examples...11 High-density system using conventional cooling 11 High-density system using chilled-water cooling 12 Conclusion...13 For more information...14 Call to action ...14
... three-phase UPSs 7 Three-phase power distribution technology 8 Load balancing and monitoring ...8 Cable reduction ...9 HP solutions: PDR and pre-configured distribution cables 10 Configuration examples...11 High-density system using conventional cooling 11 High-density system using chilled-water cooling 12 Conclusion...13 For more information...14 Call to action ...14
Increasing energy efficiency with modular HP three-phase power distribution
Page 10
... off the distribution panel, with user-adjustable alarm levels and the capability of remote control and status through a single IP address. Figure 11. HP solutions: PDR and pre-configured distribution cables The HP Power Distribution Rack (Figure 10) consists of an HP 10000-series rack ...configured with two 400-amp, 42-pole distribution panels for a maximum of IT equipment racks. Functional block diagram of power distribution cables (Figure 11) for convection (non-forced) air cooling under full-load operation. Figure 10. HP power distribution cable 10 HP offers a selection of ...
... off the distribution panel, with user-adjustable alarm levels and the capability of remote control and status through a single IP address. Figure 11. HP solutions: PDR and pre-configured distribution cables The HP Power Distribution Rack (Figure 10) consists of an HP 10000-series rack ...configured with two 400-amp, 42-pole distribution panels for a maximum of IT equipment racks. Functional block diagram of power distribution cables (Figure 11) for convection (non-forced) air cooling under full-load operation. Figure 10. HP power distribution cable 10 HP offers a selection of ...
Increasing energy efficiency with modular HP three-phase power distribution
Page 11
... as above Same as above Configuration examples This section includes basic configurations for using HP three-phase power components for a certain amount of this paper. 11 The actual number of ITE racks that the racks can support: • 10 low-density racks at 6 kilowatts per rack (larger than 2U servers, storage...
... as above Same as above Configuration examples This section includes basic configurations for using HP three-phase power components for a certain amount of this paper. 11 The actual number of ITE racks that the racks can support: • 10 low-density racks at 6 kilowatts per rack (larger than 2U servers, storage...
Technology for remote management of power distribution
Page 1
Technology for remote management of power distribution technology brief Abstract...2 Introduction...2 Implementation strategies...4 Power distribution strategies ...4 Power management strategies ...5 Management through the web interface 6 Management through telnet or terminal emulation 10 Integration with HP SIM...11 ModBus support ...11 Conclusion...11 For more information...12 Call to action ...12
Technology for remote management of power distribution technology brief Abstract...2 Introduction...2 Implementation strategies...4 Power distribution strategies ...4 Power management strategies ...5 Management through the web interface 6 Management through telnet or terminal emulation 10 Integration with HP SIM...11 ModBus support ...11 Conclusion...11 For more information...12 Call to action ...12
Technology for remote management of power distribution
Page 3
... 400-amp 42-pole (North America) distribution panels for data centers using RTU or TCP protocols. HP PDR Management Module Item Description 1 RJ-11 serial port 2 (not for PDR use) 3 Power LED 4 Error LED 5 Reset button 6 RJ-45 10/100 Ethernet port 7 (not for PDR... use) 8 RJ-11 configuration/pass-through a serial or network interface using a zoned infrastructure. Remote monitoring provides comprehensive power data from individual branch circuits to a remote terminal and...
... 400-amp 42-pole (North America) distribution panels for data centers using RTU or TCP protocols. HP PDR Management Module Item Description 1 RJ-11 serial port 2 (not for PDR use) 3 Power LED 4 Error LED 5 Reset button 6 RJ-45 10/100 Ethernet port 7 (not for PDR... use) 8 RJ-11 configuration/pass-through a serial or network interface using a zoned infrastructure. Remote monitoring provides comprehensive power data from individual branch circuits to a remote terminal and...
Technology for remote management of power distribution
Page 11
... management through HP SIM: 1. The HP SIM All Systems page lists the newly detected management module with a hyperlink to avoid unscheduled downtime and wasted power. 11 Information such as the IT equipment it supports. HP SIM allows facility managers to send SNMP traps the server running HP SIM.
... management through HP SIM: 1. The HP SIM All Systems page lists the newly detected management module with a hyperlink to avoid unscheduled downtime and wasted power. 11 Information such as the IT equipment it supports. HP SIM allows facility managers to send SNMP traps the server running HP SIM.
HP Uninterruptible Power System T2200 XR Models User Guide
Page 18
... indicators provide an easy-to-use interface for UPS configuration and monitoring. 1 2 3 4 5 8 9 6 10 7 15 14 12 11 13 Figure 2-1: Front panel controls and LED indicators Item Description Meaning/Function 1 Overload LED Red-UPS load exceeds maximum power available. 2 76%...load Green-UPS load approximately 0% to the instructions included with the UPS. continued HP Uninterruptible Power System T2200 XR Models User Guide 2-1 HP CONFIDENTIAL Codename: Matilda Part Number: 215503-002 Last Saved On: 8/19/02 2:13 PM Topics include the front panel controls, LED indicators, ...
... indicators provide an easy-to-use interface for UPS configuration and monitoring. 1 2 3 4 5 8 9 6 10 7 15 14 12 11 13 Figure 2-1: Front panel controls and LED indicators Item Description Meaning/Function 1 Overload LED Red-UPS load exceeds maximum power available. 2 76%...load Green-UPS load approximately 0% to the instructions included with the UPS. continued HP Uninterruptible Power System T2200 XR Models User Guide 2-1 HP CONFIDENTIAL Codename: Matilda Part Number: 215503-002 Last Saved On: 8/19/02 2:13 PM Topics include the front panel controls, LED indicators, ...
HP Uninterruptible Power System T2200 XR Models User Guide
Page 19
... Wiring Fault Indicator ( ) 7 Utility LED ( ) 8 Bad Battery/Low Battery ( ) 9 On Battery ( ) 10 General Alarm ( ) 11 Configure Mode On LED 12 Configure button 13 Test/Alarm Reset button 14 Standby button 15 On button Meaning/Function Red-No ground connection exists ...removed). Red-Battery is supplying utility power and the audible alarm should be updated. 2-2 HP Uninterruptible Power System T2200 XR Models User Guide HP CONFIDENTIAL Codename: Matilda Part Number: 215503-002 Last Saved On: 8/19/02 2:13 PM Places the UPS in Standby mode. Batteries charge if needed....
... Wiring Fault Indicator ( ) 7 Utility LED ( ) 8 Bad Battery/Low Battery ( ) 9 On Battery ( ) 10 General Alarm ( ) 11 Configure Mode On LED 12 Configure button 13 Test/Alarm Reset button 14 Standby button 15 On button Meaning/Function Red-No ground connection exists ...removed). Red-Battery is supplying utility power and the audible alarm should be updated. 2-2 HP Uninterruptible Power System T2200 XR Models User Guide HP CONFIDENTIAL Codename: Matilda Part Number: 215503-002 Last Saved On: 8/19/02 2:13 PM Places the UPS in Standby mode. Batteries charge if needed....
Power Products Software Reference Guide
Page 3
... Getting Help ...ix Compaq Technical Support ix Compaq Website ix Compaq Authorized Reseller ix 1 Chapter Overview How Compaq Power Management Software Works 1-2 CD Contents ...1-3 Online User Manuals 1-4 2 Chapter Installation System Requirements 2-1 Compaq UPS Load Segment Configurator... 2-2 Installing the Console on the System Administrator's Workstation 2-2 Installing from the Compaq Power Management Software CD 2-3 Installing from the Compaq Management CD 2-3 Installing the UPS Management Agent on Network Servers 2-4 Installing from the Compaq...
... Getting Help ...ix Compaq Technical Support ix Compaq Website ix Compaq Authorized Reseller ix 1 Chapter Overview How Compaq Power Management Software Works 1-2 CD Contents ...1-3 Online User Manuals 1-4 2 Chapter Installation System Requirements 2-1 Compaq UPS Load Segment Configurator... 2-2 Installing the Console on the System Administrator's Workstation 2-2 Installing from the Compaq Power Management Software CD 2-3 Installing from the Compaq Management CD 2-3 Installing the UPS Management Agent on Network Servers 2-4 Installing from the Compaq...
Power Products Software Reference Guide
Page 4
iv Compaq Power Products Software Reference Guide 3 Chapter Operation Using the Information Features 3-1 Status Window 3-2 PowerScope Window 3-4 Logs Window...3-7 Using the Operations Features 3-9 Diagnostics Window 3-9 Shutdown/Reboot Window 3-11 Using the Customization and Configuration Features 3-13 Shutdown Timing Window 3-13 Startup Timing Window 3-16 Alert Handling Window 3-18 Attachments Window 3-20 Shutdown Schedule Window 3-22 4 Chapter Troubleshooting Significant Power Events 4-1 Error Messages...4-3 A Appendix Alert Message Texts
iv Compaq Power Products Software Reference Guide 3 Chapter Operation Using the Information Features 3-1 Status Window 3-2 PowerScope Window 3-4 Logs Window...3-7 Using the Operations Features 3-9 Diagnostics Window 3-9 Shutdown/Reboot Window 3-11 Using the Customization and Configuration Features 3-13 Shutdown Timing Window 3-13 Startup Timing Window 3-16 Alert Handling Window 3-18 Attachments Window 3-20 Shutdown Schedule Window 3-22 4 Chapter Troubleshooting Significant Power Events 4-1 Error Messages...4-3 A Appendix Alert Message Texts
Power Products Software Reference Guide
Page 23
... this guide, "Accounting" is the name used for network communications must have the longest shutdown time of the Compaq Power Management software options. I A red border indicates there is a System Failure message. Investigate immediately. Installation 2-11 IMPORTANT: Since the group Controller is responsible for managing the shutdown of all systems in a power failure...
... this guide, "Accounting" is the name used for network communications must have the longest shutdown time of the Compaq Power Management software options. I A red border indicates there is a System Failure message. Investigate immediately. Installation 2-11 IMPORTANT: Since the group Controller is responsible for managing the shutdown of all systems in a power failure...
Power Products Software Reference Guide
Page 36
...to shut down the UPS. Shutdown/Reboot window If a system shutdown is restarted manually. Compaq Power Management software can be permanent (powers off the unit) until the UPS is necessary, the Compaq Power Management software saves only named files. CAUTION: To avoid data loss if a power ...failure occurs, name any user-specified interval. Operation 3-11 Shutdown/Reboot Window Use the UPS Shutdown/Reboot window to a value...
...to shut down the UPS. Shutdown/Reboot window If a system shutdown is restarted manually. Compaq Power Management software can be permanent (powers off the unit) until the UPS is necessary, the Compaq Power Management software saves only named files. CAUTION: To avoid data loss if a power ...failure occurs, name any user-specified interval. Operation 3-11 Shutdown/Reboot Window Use the UPS Shutdown/Reboot window to a value...
Power Products Software Reference Guide
Page 43
... Handling Window Use the Alert Handling window to change the text of all alert message texts, see Appendix A, "Alert Message Texts." Figure 3-11. Alert Handling window For a complete list of a Compaq Power Management (CPM) message, or to cause the system to execute a command or send E-mail or a broadcast message to users if...
... Handling Window Use the Alert Handling window to change the text of all alert message texts, see Appendix A, "Alert Message Texts." Figure 3-11. Alert Handling window For a complete list of a Compaq Power Management (CPM) message, or to cause the system to execute a command or send E-mail or a broadcast message to users if...
Power Products Software Reference Guide
Page 56
A-2 Compaq Power Products Software Reference Guide Table A-1 Alert Message Texts continued Number Message Text 10 Communications failure with UPS 11 Communications established with UPS 12 Abnormal operation 13 Abnormal operation resolved 14 Utility power failure 15 Utility power failure resolved 16 Low battery 17 Low ...
A-2 Compaq Power Products Software Reference Guide Table A-1 Alert Message Texts continued Number Message Text 10 Communications failure with UPS 11 Communications established with UPS 12 Abnormal operation 13 Abnormal operation resolved 14 Utility power failure 15 Utility power failure resolved 16 Low battery 17 Low ...
Power Products Software Reference Guide
Page 69
... cables from the Six Port Cards ( ) and Power connections from the UPS XR models to the servers ( ) IMPORTANT: Refer to the installation instructions supplied with the UPS kit) before installing this product. Compaq UPS Options B-11 1 2 Figure B-9. Compaq Insight Manager and Compaq Power Management software will recognize the UPS option cards automatically when installation is...
... cables from the Six Port Cards ( ) and Power connections from the UPS XR models to the servers ( ) IMPORTANT: Refer to the installation instructions supplied with the UPS kit) before installing this product. Compaq UPS Options B-11 1 2 Figure B-9. Compaq Insight Manager and Compaq Power Management software will recognize the UPS option cards automatically when installation is...