Updating Firmware via USB to Serial Connection
Page 1
... to COM 1. 2. The Port Properties screen appears. 7. The Port Settings screen appears. 8. Click OK to inaccessible devices and changed settings. Run the firmware Flash batch file program. The Port Properties screen appears. 3. See "Reassigning the USB COM ports." 11. Do you want to select low (1). 12. Choose the lowest, most dependable...
... to COM 1. 2. The Port Properties screen appears. 7. The Port Settings screen appears. 8. Click OK to inaccessible devices and changed settings. Run the firmware Flash batch file program. The Port Properties screen appears. 3. See "Reassigning the USB COM ports." 11. Do you want to select low (1). 12. Choose the lowest, most dependable...
Technology for remote management of power distribution
Page 10
... and restart r Restore Configuration to Manufacturer Settings PDR Monitor menu 1 PDR Alarms 2 PDR Meters 0 Previous Menu Network Configuration menu 1 Network Settings 2 Remote Console 3 Web Access 4 File Transfer 5 SNMP 6 Session Settings 0 Previous Menu ModBus Configuration menu 1 Modbus Protocol Selection 2 RTU Device Address [1 to 247] 3 TCP Device Address [0 to 255] 4 TCP Device Port...
... and restart r Restore Configuration to Manufacturer Settings PDR Monitor menu 1 PDR Alarms 2 PDR Meters 0 Previous Menu Network Configuration menu 1 Network Settings 2 Remote Console 3 Web Access 4 File Transfer 5 SNMP 6 Session Settings 0 Previous Menu ModBus Configuration menu 1 Modbus Protocol Selection 2 RTU Device Address [1 to 247] 3 TCP Device Address [0 to 255] 4 TCP Device Port...
Technology for remote management of power distribution
Page 11
...as important as monthly/yearly/total kW hours per breaker is launched and automatically detects the new management module. 3. The HP Power MIB file is installed and connected into HP SIM before traps can be integrated with a hyperlink to discover (detect) newly installed HP PDR Management...web interface. ModBus is an industry-standard communications protocol for instance, can be used by the HP SIM server. 2. Note The correct MIB file (cpqpower.mib) must be received. The HP PDR Management Module supports both ModBus/RTU (serial) and ModBus/TCP (Ethernet) protocols, although...
...as important as monthly/yearly/total kW hours per breaker is launched and automatically detects the new management module. 3. The HP Power MIB file is installed and connected into HP SIM before traps can be integrated with a hyperlink to discover (detect) newly installed HP PDR Management...web interface. ModBus is an industry-standard communications protocol for instance, can be used by the HP SIM server. 2. Note The correct MIB file (cpqpower.mib) must be received. The HP PDR Management Module supports both ModBus/RTU (serial) and ModBus/TCP (Ethernet) protocols, although...
Power Products Software Reference Guide
Page 6
... FILENAMES Menu Options, Command Names, Field Names, Dialog Box Names COMMANDS, FOLDER NAMES, DIRECTORY NAMES, and DRIVE NAMES ^ Type Enter These elements appear in boldface. File names appear in uppercase letters. These elements appear in initial capital letters and boldface. About This Guide This guide is designed to enter information, type...
... FILENAMES Menu Options, Command Names, Field Names, Dialog Box Names COMMANDS, FOLDER NAMES, DIRECTORY NAMES, and DRIVE NAMES ^ Type Enter These elements appear in boldface. File names appear in uppercase letters. These elements appear in initial capital letters and boldface. About This Guide This guide is designed to enter information, type...
Power Products Software Reference Guide
Page 11
.... The Agent saves work -in-progress throughout the network, and preserving files that are divided into two or more critical equipment is lost (or insufficient to a permanent storage medium. Overview 1-3 Compaq Power Management software constantly observes the power environment of your system based on... multiple load segments to the system administrator's personal computer (PC) using SNMP. By communicating with CPM software, the Compaq UPS can be configured to the alert as programmed by the user. In addition, the power-scheduling feature allows for connected equipment.
.... The Agent saves work -in-progress throughout the network, and preserving files that are divided into two or more critical equipment is lost (or insufficient to a permanent storage medium. Overview 1-3 Compaq Power Management software constantly observes the power environment of your system based on... multiple load segments to the system administrator's personal computer (PC) using SNMP. By communicating with CPM software, the Compaq UPS can be configured to the alert as programmed by the user. In addition, the power-scheduling feature allows for connected equipment.
Power Products Software Reference Guide
Page 12
... Power Manager context-sensitive help file called MANUAL.HLP. 1-4 Compaq Power Products Software Reference Guide Online User Manuals There is an online user manual for LanSafe III is a Windows help screens by pressing the F1 key. A manual for the Compaq Power Management software included in ...portable document format (PDF), which requires Adobe Acrobat Reader version 2.0 or later (also provided on the Compaq Power Management software CD. The online manual is available in the ...
... Power Manager context-sensitive help file called MANUAL.HLP. 1-4 Compaq Power Products Software Reference Guide Online User Manuals There is an online user manual for LanSafe III is a Windows help screens by pressing the F1 key. A manual for the Compaq Power Management software included in ...portable document format (PDF), which requires Adobe Acrobat Reader version 2.0 or later (also provided on the Compaq Power Management software CD. The online manual is available in the ...
Power Products Software Reference Guide
Page 22
... segment assignment, individual settings may be changed using the Attachments feature (described in Chapter 3, "Operation"). 2-10 Compaq Power Products Software Reference Guide 4. The HOSTS file may be assigned to the load segment to the /ETC/HOSTS file before it is attached by using a text editor (OpenServer and UNIXWare 7.x) or with the Internet Setup...
... segment assignment, individual settings may be changed using the Attachments feature (described in Chapter 3, "Operation"). 2-10 Compaq Power Products Software Reference Guide 4. The HOSTS file may be assigned to the load segment to the /ETC/HOSTS file before it is attached by using a text editor (OpenServer and UNIXWare 7.x) or with the Internet Setup...
Power Products Software Reference Guide
Page 30
... shutdown will occur in one minute or less. ❏ If the Load% value is in one minute or less. Save work and close files immediately, then resolve the problem. If the colors on the right side of the PowerScope window, the Volts Out section shows the voltage of...Buck and Boost-A proprietary line regulation process used when an overvoltage or undervoltage situation occurs in the yellow or red range, save work and close files immediately, then resolve the problem. Undervoltage is boosted to reduce the voltage, thus lessening reliance on the battery. CAUTION: An extended red value ...
... shutdown will occur in one minute or less. ❏ If the Load% value is in one minute or less. Save work and close files immediately, then resolve the problem. If the colors on the right side of the PowerScope window, the Volts Out section shows the voltage of...Buck and Boost-A proprietary line regulation process used when an overvoltage or undervoltage situation occurs in the yellow or red range, save work and close files immediately, then resolve the problem. Undervoltage is boosted to reduce the voltage, thus lessening reliance on the battery. CAUTION: An extended red value ...
Power Products Software Reference Guide
Page 36
... for any new files as soon as they are opened. CAUTION: To avoid data loss if a power failure occurs, name any user-specified interval. I TimedThe startup can be permanent (powers off the unit) until the UPS is necessary, the Compaq Power Management software ...saves only named files. Shutdown/Reboot window If a system shutdown is restarted manually. For applications with automatic saving capability, set the Autosave time ...
... for any new files as soon as they are opened. CAUTION: To avoid data loss if a power failure occurs, name any user-specified interval. I TimedThe startup can be permanent (powers off the unit) until the UPS is necessary, the Compaq Power Management software ...saves only named files. Shutdown/Reboot window If a system shutdown is restarted manually. For applications with automatic saving capability, set the Autosave time ...
Power Products Software Reference Guide
Page 39
...to reduce nuisance messages or shortened to reduce reliance on a load segment using the following controls. This interval allows time to finish work and save files. Each minute, the user is 5 seconds. This interval can be set a power failure runtime for non-essential peripherals on the battery. I ...The default value is the sum of Wink Time, Countdown Time, and Shutdown Delay. This interval allows the system to log off . 3-14 Compaq Power Products Software Reference Guide Use the Shutdown Timing window to set the parameters for a computer shutdown, and to set at a value less ...
...to reduce nuisance messages or shortened to reduce reliance on a load segment using the following controls. This interval allows time to finish work and save files. Each minute, the user is 5 seconds. This interval can be set a power failure runtime for non-essential peripherals on the battery. I ...The default value is the sum of Wink Time, Countdown Time, and Shutdown Delay. This interval allows the system to log off . 3-14 Compaq Power Products Software Reference Guide Use the Shutdown Timing window to set the parameters for a computer shutdown, and to set at a value less ...
Power Products Software Reference Guide
Page 40
...enough to ensure that the software has time to change, then click Set. 3. To avoid loss if a power failure occurs, name any new files when they are closed. Operation 3-15 The following items should be carefully considered before the UPS batteries fully charge. I After a power outage recovery...Value window, set the Countdown Time to a value small enough to allow the UPS to which power is necessary, the Compaq Power Management software saves only named files. Set a new value in the system are opened. Configuring Computer Shutdown Timing 1. Press the Set button. Right-click ...
...enough to ensure that the software has time to change, then click Set. 3. To avoid loss if a power failure occurs, name any new files when they are closed. Operation 3-15 The following items should be carefully considered before the UPS batteries fully charge. I After a power outage recovery...Value window, set the Countdown Time to a value small enough to allow the UPS to which power is necessary, the Compaq Power Management software saves only named files. Set a new value in the system are opened. Configuring Computer Shutdown Timing 1. Press the Set button. Right-click ...
Power Products Software Reference Guide
Page 52
...is getting the following table. No power. Compaq Insight Manager is configured for a previous version of Compaq UPS products. The NetWare server has the old CPQUPS driver and CPQUPSSA agent loaded. Configuration File. Refer to a working outlet and that may... communications port than the computer interface cable. Table 4-1 Error Messages Possible Cause Compaq Insight Manager is configured for instructions. continued Solution Reconfigure the communications port in Compaq Insight Manager. Unable to Contact. Troubleshooting 4-3 Error Messages Specific troubleshooting items that...
...is getting the following table. No power. Compaq Insight Manager is configured for a previous version of Compaq UPS products. The NetWare server has the old CPQUPS driver and CPQUPSSA agent loaded. Configuration File. Refer to a working outlet and that may... communications port than the computer interface cable. Table 4-1 Error Messages Possible Cause Compaq Insight Manager is configured for instructions. continued Solution Reconfigure the communications port in Compaq Insight Manager. Unable to Contact. Troubleshooting 4-3 Error Messages Specific troubleshooting items that...
Power Products Software Reference Guide
Page 54
...Solution Unload all the leading zeros. Each of the Group Controller may have not been entered correctly when running CPQSETUP.NLM. 'Error copying files' when running CPMSETUP.NLM on a NetWare server. There should be in place, so it can not establish connection with all the ...the Group Controller using CAPS for all other messages. Note: Contact your system administrator for A through F. When asked to copy configuration files from during setup. The appropriate directory structure is not available for CPMSETUP.NLM to enter the IPX address of the directory structure be ...
...Solution Unload all the leading zeros. Each of the Group Controller may have not been entered correctly when running CPQSETUP.NLM. 'Error copying files' when running CPMSETUP.NLM on a NetWare server. There should be in place, so it can not establish connection with all the ...the Group Controller using CAPS for all other messages. Note: Contact your system administrator for A through F. When asked to copy configuration files from during setup. The appropriate directory structure is not available for CPMSETUP.NLM to enter the IPX address of the directory structure be ...
Power Products Software Reference Guide
Page 64
...the SNMP-EN Adapter communications interface, you quickly ascertain if a power-related problem exists anywhere on which Compaq Insight Management Agents cannot be installed. The SNMP-EN Adapter will help you can virtually eliminate costly downtime... the UPS, independent of connected computers. B-6 Compaq Power Products Software Reference Guide Compaq SNMP-EN Adapter Figure B-5. SNMP-EN Adapter The Compaq SNMP-EN Adapter provides a network interface to -day network management annoyances like spontaneous rebooting, lost files and corrupted dataissues resulting from inconsistent ...
...the SNMP-EN Adapter communications interface, you quickly ascertain if a power-related problem exists anywhere on which Compaq Insight Management Agents cannot be installed. The SNMP-EN Adapter will help you can virtually eliminate costly downtime... the UPS, independent of connected computers. B-6 Compaq Power Products Software Reference Guide Compaq SNMP-EN Adapter Figure B-5. SNMP-EN Adapter The Compaq SNMP-EN Adapter provides a network interface to -day network management annoyances like spontaneous rebooting, lost files and corrupted dataissues resulting from inconsistent ...
Power Products Software Reference Guide
Page 67
... possible by direct communication with the UPS, independent of UPS XR models. Using the SNMP/Serial Port Card communications interface, you quickly ascertain if a power-related problem exists anywhere on which Compaq Insight Management Agents cannot be installed. This 3U rack option ...the available battery runtime of connected computers. Compaq UPS Options B-9 In addition to -day network management annoyances like spontaneous rebooting, lost files and corrupted dataissues resulting from inconsistent power. SNMP/Serial Port Card The Compaq SNMP/Serial Port Card provides a network ...
... possible by direct communication with the UPS, independent of UPS XR models. Using the SNMP/Serial Port Card communications interface, you quickly ascertain if a power-related problem exists anywhere on which Compaq Insight Management Agents cannot be installed. This 3U rack option ...the available battery runtime of connected computers. Compaq UPS Options B-9 In addition to -day network management annoyances like spontaneous rebooting, lost files and corrupted dataissues resulting from inconsistent power. SNMP/Serial Port Card The Compaq SNMP/Serial Port Card provides a network ...
Power Products Software Reference Guide
Page 72
...3-11 SNMP trap 1-3 functionality 1-1, 1-2 installing 2-1 Compaq Insight Managers Agents 2-1 Console 2-1, 2-2 CPM Management Agent 2-1 installing Console 2-3 installing UPS Management Agent 2-5 Compaq UPS Load Segment Configurator utility software described 2-2 installation ...Compaq Power Management software CD 2-3 Customization and Configuration features 3-13 D Device Software button 2-13 Diagnostics button 2-12 running 3-9 window, figure 3-9 E ERM See Extended Runtime Module error messages 4-3 can not establish connection 4-4 communications error 4-3 configuration file 4-3 error copying files...
...3-11 SNMP trap 1-3 functionality 1-1, 1-2 installing 2-1 Compaq Insight Managers Agents 2-1 Console 2-1, 2-2 CPM Management Agent 2-1 installing Console 2-3 installing UPS Management Agent 2-5 Compaq UPS Load Segment Configurator utility software described 2-2 installation ...Compaq Power Management software CD 2-3 Customization and Configuration features 3-13 D Device Software button 2-13 Diagnostics button 2-12 running 3-9 window, figure 3-9 E ERM See Extended Runtime Module error messages 4-3 can not establish connection 4-4 communications error 4-3 configuration file 4-3 error copying files...
Power Products Software Reference Guide
Page 74
4 Compaq Power Products Software Reference Guide Volts Out, colors defined 3-5 window 3-4 window, figure 3-4 PowerScope button 2-12 Preventative Maintenance Alarm enable 3-10 window, figure 3-10 R Recovery button...restart delay, setting 3-16 RS-232 serial port 2-1 S safety information viii Scalable UPS Card B-1 described B-4 figure B-4 Scheduled Shutdown timing window, figure 3-24 SCO 5 2-5, 2-6 Shutdown naming files 3-11 Shutdown Sched. button 2-13 Shutdown Schedule described 3-23 Shutdown Timing 3-13 Alert Message Transmission Time 3-14 button 2-12 cautions 3-15 configuring 3-15 Countdown Time...
4 Compaq Power Products Software Reference Guide Volts Out, colors defined 3-5 window 3-4 window, figure 3-4 PowerScope button 2-12 Preventative Maintenance Alarm enable 3-10 window, figure 3-10 R Recovery button...restart delay, setting 3-16 RS-232 serial port 2-1 S safety information viii Scalable UPS Card B-1 described B-4 figure B-4 Scheduled Shutdown timing window, figure 3-24 SCO 5 2-5, 2-6 Shutdown naming files 3-11 Shutdown Sched. button 2-13 Shutdown Schedule described 3-23 Shutdown Timing 3-13 Alert Message Transmission Time 3-14 button 2-12 cautions 3-15 configuring 3-15 Countdown Time...