Software Guide
Page 380
...Supervisor WS-X6K-SUP1-2GE ok 2 2 24 100BaseFX MM Ethernet WS-X6224-100FX-MT ok 33 8 1000BaseX Ethernet WS-X6408-GBIC ok 4 4 48 10/100BaseTX (Telco) WS-X6248-TEL ok 5 5 48 10/100BaseTX (RJ-45) WS...Sub-Serial Sub-Hw 1 L2 Switching Engine I WS-F6020 SAD03040312 1.0 Console> (enable) ...WS-X6248-TEL ok Mod Module-Name Serial-Num 4 SAD03140787 Mod MAC-Address(es) Hw Fw Sw 4 00-50-54-bf-59-64 to 00-50-54-bf-59-93 0.103 4.2(0.24)V 5.2(1)CSX Console> (enable) Checking Port Status You can see the "Checking Module Status" section on page 19-1. 19-2 Catalyst 6000...
...Supervisor WS-X6K-SUP1-2GE ok 2 2 24 100BaseFX MM Ethernet WS-X6224-100FX-MT ok 33 8 1000BaseX Ethernet WS-X6408-GBIC ok 4 4 48 10/100BaseTX (Telco) WS-X6248-TEL ok 5 5 48 10/100BaseTX (RJ-45) WS...Sub-Serial Sub-Hw 1 L2 Switching Engine I WS-F6020 SAD03040312 1.0 Console> (enable) ...WS-X6248-TEL ok Mod Module-Name Serial-Num 4 SAD03140787 Mod MAC-Address(es) Hw Fw Sw 4 00-50-54-bf-59-64 to 00-50-54-bf-59-93 0.103 4.2(0.24)V 5.2(1)CSX Console> (enable) Checking Port Status You can see the "Checking Module Status" section on page 19-1. 19-2 Catalyst 6000...
Software Guide
Page 382
... to access other devices in a switch using Telnet. Up to display the port capabilities for switch ports: Console> (enable) show port capabilities 1/1 Model WS-X6K-SUP1A-2GE Port 1/1 Type No Connector Speed 1000 Duplex full Trunk encap type 802.1Q,ISL Trunk mode on,off,desirable,auto,nonegotiate Channel yes Broadcast suppression...-line interface (CLI) using the show port capabilities [[mod][/port]] command. In addition, you how to eight simultaneous Telnet sessions are possible. 19-4 Catalyst 6000 Family Software Configuration Guide-Releases 6.3 and 6.4 78-13315-02
... to access other devices in a switch using Telnet. Up to display the port capabilities for switch ports: Console> (enable) show port capabilities 1/1 Model WS-X6K-SUP1A-2GE Port 1/1 Type No Connector Speed 1000 Duplex full Trunk encap type 802.1Q,ISL Trunk mode on,off,desirable,auto,nonegotiate Channel yes Broadcast suppression...-line interface (CLI) using the show port capabilities [[mod][/port]] command. In addition, you how to eight simultaneous Telnet sessions are possible. 19-4 Catalyst 6000 Family Software Configuration Guide-Releases 6.3 and 6.4 78-13315-02
Software Guide
Page 404
... Requirements Module Supervisor Engine 1: WS-X6K-SUP1A-2GE WS-X6K-SUP1-2GE Supervisor Engine 1 with PFC: WS-X6K-SUP1A-PFC Supervisor Engine 1 with PFC and MSFC: WS-X6K-SUP1A-MSFC Supervisor Engine 1 with PFC and MSFC2: WS-X6K-S1A-MSFC2 Supervisor Engine 2 with PFC2: WS-X6K-S2-PFC2 Supervisor Engine 2 with PFC2 and MSFC2: WS-X6K-S2-MSFC2 MSFC2 (spare): WS-F6K-MSFC2= Multilayer Switching Module: WS-X6302-MSM 24-Port 10BASE-FL: WS-X6024-10FL-MT Switch Fabric Modules: WS-C6500-SFM WS-X6500-SFM2...
... Requirements Module Supervisor Engine 1: WS-X6K-SUP1A-2GE WS-X6K-SUP1-2GE Supervisor Engine 1 with PFC: WS-X6K-SUP1A-PFC Supervisor Engine 1 with PFC and MSFC: WS-X6K-SUP1A-MSFC Supervisor Engine 1 with PFC and MSFC2: WS-X6K-S1A-MSFC2 Supervisor Engine 2 with PFC2: WS-X6K-S2-PFC2 Supervisor Engine 2 with PFC2 and MSFC2: WS-X6K-S2-MSFC2 MSFC2 (spare): WS-F6K-MSFC2= Multilayer Switching Module: WS-X6302-MSM 24-Port 10BASE-FL: WS-X6024-10FL-MT Switch Fabric Modules: WS-C6500-SFM WS-X6500-SFM2...
Software Guide
Page 479
...L2 Switching Engine WS-F6020 SAD02350211 0.101 Console> (enable) 78-13315-02 Catalyst 6000 Family Software Configuration Guide-Releases 6.3 and 6.4 22-5 In addition, the STATUS LED on any of the standby supervisor engine using a...supervisor engine show module [mod] Show the state of the standby supervisor engine. Verifying Standby Supervisor Engine Status You can verify the status of the standby supervisor engine using the show module and show test commands: Console> (enable) show module 2 Mod Slot Ports Module-Type Model Status 22 2 1000BaseX Supervisor WS-X6K-SUP1-2GE...
...L2 Switching Engine WS-F6020 SAD02350211 0.101 Console> (enable) 78-13315-02 Catalyst 6000 Family Software Configuration Guide-Releases 6.3 and 6.4 22-5 In addition, the STATUS LED on any of the standby supervisor engine using a...supervisor engine show module [mod] Show the state of the standby supervisor engine. Verifying Standby Supervisor Engine Status You can verify the status of the standby supervisor engine using the show module and show test commands: Console> (enable) show module 2 Mod Slot Ports Module-Type Model Status 22 2 1000BaseX Supervisor WS-X6K-SUP1-2GE...
Software Guide
Page 659
... follows based upon the type of supervisor engine you have: - WS-X6K-SUP1A-PFC, WS-X6K-SUP1A-MSFC, WS-X6K-SUP1A-MSFC2, WS-X6K-SUP2-PFC2, WS-X6K-SUP2-MSFC2-Two packets are forwarded by the trunk settings of the destination port during SPAN session configuration. WS-X6K-SUP1-2GE, WS-X6K-SUP1A-2GE-Only one or more VLANs. Chapter... ports for analysis at the destination port. All the ports in the source VLANs become RSPAN VLANs. 78-13315-02 Catalyst 6000 Family Software Configuration Guide-Releases 6.3 and 6.4 38-3 VSPAN VLAN-based SPAN (VSPAN) is made inactive if any SPAN...
... follows based upon the type of supervisor engine you have: - WS-X6K-SUP1A-PFC, WS-X6K-SUP1A-MSFC, WS-X6K-SUP1A-MSFC2, WS-X6K-SUP2-PFC2, WS-X6K-SUP2-MSFC2-Two packets are forwarded by the trunk settings of the destination port during SPAN session configuration. WS-X6K-SUP1-2GE, WS-X6K-SUP1A-2GE-Only one or more VLANs. Chapter... ports for analysis at the destination port. All the ports in the source VLANs become RSPAN VLANs. 78-13315-02 Catalyst 6000 Family Software Configuration Guide-Releases 6.3 and 6.4 38-3 VSPAN VLAN-based SPAN (VSPAN) is made inactive if any SPAN...
Software Guide
Page 714
...supervisor engine to be one of the following: • Supervisor Engine 2 (WS-X6K-SUP2-2GE) with Layer 3 Switching Engine II (WS-F6K-PFC2-Policy Feature Card 2 or PFC2) • Supervisor Engine 1 (WS-X6K-SUP1A-2GE or WS-X6K-SUP1-2GE) with one of the following: - The two Layer 2 switching engines support the same QoS feature set on your switching engine... 41-8 Catalyst 6000 Family Software Configuration Guide-Releases 6.3 and 6.4 78-13315-02 Understanding How QoS Works Chapter 41 Configuring QoS Figure 41-7 Single-Port ATM OC-12 Switching Module Marking From switching engine or MSFC...
...supervisor engine to be one of the following: • Supervisor Engine 2 (WS-X6K-SUP2-2GE) with Layer 3 Switching Engine II (WS-F6K-PFC2-Policy Feature Card 2 or PFC2) • Supervisor Engine 1 (WS-X6K-SUP1A-2GE or WS-X6K-SUP1-2GE) with one of the following: - The two Layer 2 switching engines support the same QoS feature set on your switching engine... 41-8 Catalyst 6000 Family Software Configuration Guide-Releases 6.3 and 6.4 78-13315-02 Understanding How QoS Works Chapter 41 Configuring QoS Figure 41-7 Single-Port ATM OC-12 Switching Module Marking From switching engine or MSFC...
Software Guide
Page 810
... mod This example shows how to display module information: Console> (enable) show commands supported by the Switch Fabric Module from the supervisor engine. The module in slot 5 functions as the primary module and a redundant Switch Fabric Module in privileged mode: Task Display the...Note Enter all show module Mod Slot Ports Module-Type Model Sub Status 11 2 1000BaseX Supervisor WS-X6K-SUP2-2GE yes ok 4 4 24 100BaseFX MM Ethernet WS-X6224-MM-MT no ok 43-4 Catalyst 6000 Family Software Configuration Guide-Releases 6.3 and 6.4 78-13315-02 Configuring and Monitoring the ...
... mod This example shows how to display module information: Console> (enable) show commands supported by the Switch Fabric Module from the supervisor engine. The module in slot 5 functions as the primary module and a redundant Switch Fabric Module in privileged mode: Task Display the...Note Enter all show module Mod Slot Ports Module-Type Model Sub Status 11 2 1000BaseX Supervisor WS-X6K-SUP2-2GE yes ok 4 4 24 100BaseFX MM Ethernet WS-X6224-MM-MT no ok 43-4 Catalyst 6000 Family Software Configuration Guide-Releases 6.3 and 6.4 78-13315-02 Configuring and Monitoring the ...
Software Guide
Page 827
... Mod Slot Ports Module-Type Model Sub Status 11 2 1000BaseX Supervisor WS-X6K-SUP1A-2GE yes ok 15 1 1 Multilayer Switch Feature WS-F6K-MSFC no ok 8 8 48 10/100BaseTX Ethernet WS-X6348-RJ-45 no ok 9 9 48 10/100BaseTX Ethernet WS-X6348-RJ-45 yes ok Mod Module-Name Serial-Num 1 SAD03436055...a5-04 to Display Module Type and Version Information The Catalyst 6000 family 48-port 10/100BASE-TX Ethernet switching module has three versions: • WS-X6248-RJ-45-standard 10/100BASE-TX switching module • WS-X6348-RJ-45-enhanced 10/100BASE-TX switching module (enhanced...
... Mod Slot Ports Module-Type Model Sub Status 11 2 1000BaseX Supervisor WS-X6K-SUP1A-2GE yes ok 15 1 1 Multilayer Switch Feature WS-F6K-MSFC no ok 8 8 48 10/100BaseTX Ethernet WS-X6348-RJ-45 no ok 9 9 48 10/100BaseTX Ethernet WS-X6348-RJ-45 yes ok Mod Module-Name Serial-Num 1 SAD03436055...a5-04 to Display Module Type and Version Information The Catalyst 6000 family 48-port 10/100BASE-TX Ethernet switching module has three versions: • WS-X6248-RJ-45-standard 10/100BASE-TX switching module • WS-X6348-RJ-45-enhanced 10/100BASE-TX switching module (enhanced...
Software Guide
Page 828
...7c-43-00 to the connected device. 44-12 Catalyst 6000 Family Software Configuration Guide-Releases 6.3 and 6.4 78-13315-02 Configuring VoIP on -Power is supplied by the port. • Power-deny-The supervisor engine does not have enough power to allocate to power ...version of modules and submodules: Console> (enable) show version 2 Mod Port Model Serial # Versions 2 2 WS-X6K-SUP2-2GE SAD04450LF1 Hw : 1.1 Fw : 6.1(2) Fw1: 6.1(3) Sw : 6.3(0.62)PAN Sw1: 6.3(0.62)PAN WS-F6K-PFC2 SAD04440HVU Hw : 1.0 Console> Power Management Modes Each port is configured through the CLI, SNMP,...
...7c-43-00 to the connected device. 44-12 Catalyst 6000 Family Software Configuration Guide-Releases 6.3 and 6.4 78-13315-02 Configuring VoIP on -Power is supplied by the port. • Power-deny-The supervisor engine does not have enough power to allocate to power ...version of modules and submodules: Console> (enable) show version 2 Mod Port Model Serial # Versions 2 2 WS-X6K-SUP2-2GE SAD04450LF1 Hw : 1.1 Fw : 6.1(2) Fw1: 6.1(3) Sw : 6.3(0.62)PAN Sw1: 6.3(0.62)PAN WS-F6K-PFC2 SAD04440HVU Hw : 1.0 Console> Power Management Modes Each port is configured through the CLI, SNMP,...
Software Guide
Page 835
... @ 42V) Slot power Requirement/Usage : Slot Card-Type 1 2 WS-X6K-SUP1-2GE 3 WS-X6348-RJ-45 5 WS-X6348-RJ-45 6 Unknown 7 WS-X6248-RJ-45 9 WS-X6416-GE-MT Console> (enable) Power-Requested Watts A @ 42V ...which are inline powered. Enter the set port auxiliaryvlan mod[/port] untagged command) Note The Cisco IP Phone 7960 always sets Layer 3 IP precedence to 5 in these frame types: ...0 and Layer 2 CoS set to the switch in voice traffic. 78-13315-02 Catalyst 6000 Family Software Configuration Guide-Releases 6.3 and 6.4 44-19 Configuring Auxiliary VLANs on the module...
... @ 42V) Slot power Requirement/Usage : Slot Card-Type 1 2 WS-X6K-SUP1-2GE 3 WS-X6348-RJ-45 5 WS-X6348-RJ-45 6 Unknown 7 WS-X6248-RJ-45 9 WS-X6416-GE-MT Console> (enable) Power-Requested Watts A @ 42V ...which are inline powered. Enter the set port auxiliaryvlan mod[/port] untagged command) Note The Cisco IP Phone 7960 always sets Layer 3 IP precedence to 5 in these frame types: ...0 and Layer 2 CoS set to the switch in voice traffic. 78-13315-02 Catalyst 6000 Family Software Configuration Guide-Releases 6.3 and 6.4 44-19 Configuring Auxiliary VLANs on the module...