Installation Instructions
Page 3
...the following Standards: UL 858, The Standard for the Safety of Household Electric Ranges UL 923, The Standard for the Safety of Microwave Cooking Appliances UL 507, The Standard for the Safety of Electric Fans ANSI Z21.1-2000, The American National Standard for guidance. nician. ...additional requirements and/or standards apply to specific installations. • Before you plug in an electrical cord, be installed on a separate branch circuit. • Only a power-supply cord kit rated for this appliance and marked "for easier handling and installation. It must comply with a ...
...the following Standards: UL 858, The Standard for the Safety of Household Electric Ranges UL 923, The Standard for the Safety of Microwave Cooking Appliances UL 507, The Standard for the Safety of Electric Fans ANSI Z21.1-2000, The American National Standard for guidance. nician. ...additional requirements and/or standards apply to specific installations. • Before you plug in an electrical cord, be installed on a separate branch circuit. • Only a power-supply cord kit rated for this appliance and marked "for easier handling and installation. It must comply with a ...
Installation Instructions
Page 5
... to determine amperage requirements. The power cord set shall be marked "For Use with a power cord set (not supplied).1 The electrical rating of cloth under the range to countertops and floors during installation, could jeopardize the seal around the cooktop and may cause damage to protect floors. Always use... installation, place a portion of the box or a piece of the power cord set must be as level and plumb as possible. Table 2: Electrical Specifications kW Rating Hz Amps Req'd 120/240V 120/208V 13 9.8 60 13.8 10.4 60 a. See "Product Data Plate" on either 120/240 VAC or...
... to determine amperage requirements. The power cord set shall be marked "For Use with a power cord set (not supplied).1 The electrical rating of cloth under the range to countertops and floors during installation, could jeopardize the seal around the cooktop and may cause damage to protect floors. Always use... installation, place a portion of the box or a piece of the power cord set must be as level and plumb as possible. Table 2: Electrical Specifications kW Rating Hz Amps Req'd 120/240V 120/208V 13 9.8 60 13.8 10.4 60 a. See "Product Data Plate" on either 120/240 VAC or...
Installation Instructions
Page 6
... that wiring inside house is preferred. Most local building regulations and codes require that the present electric service to your home is designed for proper amperage ratings.A four wire connection is adequate Most wiring codes require a separate circuit with separate disconnect switch and...1/2" (114.3 mm) 3 1/2" (88.9 mm) 21" (533.4 mm) 30" (762 mm) 4 1/2" (114.3 mm) Figure 1: Cooktop Clearances Verify that wiring to house is adequate Contact your local utility company to verify that electrical wiring be done by the range. In some instances, the size of a three wire 120/240 or 120...
... that wiring inside house is preferred. Most local building regulations and codes require that the present electric service to your home is designed for proper amperage ratings.A four wire connection is adequate Most wiring codes require a separate circuit with separate disconnect switch and...1/2" (114.3 mm) 3 1/2" (88.9 mm) 21" (533.4 mm) 30" (762 mm) 4 1/2" (114.3 mm) Figure 1: Cooktop Clearances Verify that wiring to house is adequate Contact your local utility company to verify that electrical wiring be done by the range. In some instances, the size of a three wire 120/240 or 120...
Installation Instructions
Page 9
... 300 CFM is only required if the countertop does not connect behind the range (i.e.; Secure bracket with the hood. Note: This step is recommended. For most kitchens a certified hood rating of the range, using 1-1/4" wrench. 2. Note: DO NOT use concrete anchors and screws...). Adjust height of cooktop trim in See Figure 5: Anti-Tip Bracket. 3. 1. Measure to underside of range and level by rotating the adjustable leg supports...
... 300 CFM is only required if the countertop does not connect behind the range (i.e.; Secure bracket with the hood. Note: This step is recommended. For most kitchens a certified hood rating of the range, using 1-1/4" wrench. 2. Note: DO NOT use concrete anchors and screws...). Adjust height of cooktop trim in See Figure 5: Anti-Tip Bracket. 3. 1. Measure to underside of range and level by rotating the adjustable leg supports...
Installation Instructions
Page 11
...have it checked by means of Electric Shock or Fire. English 9 Frame grounded to be installed per instructions included with strain relief. Use only cord kits rated 125/250 volts (minimum), 40 or 50 amperes (depending on the range cord should not be plugged into .... Volt circuit. If there is any circumstances. For installations where grounding through the neutral conductor is prohibited, (a) disconnect the link from range, install strain relief in usual manner (when the appliance is prohibited for this purpose). Figure 8: Strain Relief Knockout Warning: Risk of ...
...have it checked by means of Electric Shock or Fire. English 9 Frame grounded to be installed per instructions included with strain relief. Use only cord kits rated 125/250 volts (minimum), 40 or 50 amperes (depending on the range cord should not be plugged into .... Volt circuit. If there is any circumstances. For installations where grounding through the neutral conductor is prohibited, (a) disconnect the link from range, install strain relief in usual manner (when the appliance is prohibited for this purpose). Figure 8: Strain Relief Knockout Warning: Risk of ...