Brochure
Page 2
... with combo XLR and 1/4" TRS input connectors making the iNUKE compatible with reliable overload protection Built-in either dual mono, stereo or mono bridge mode. Powerful remote software downloadable at behringer.com "Zero-Attack" limiters offer maximum output level with virtually... any source, balanced or unbalanced. iNUKE NU6000DSP NU3000DSP NU1000DSP NU6000 NU3000 NU1000 Front panel LCD display enables setup and adjustment without ...
... with combo XLR and 1/4" TRS input connectors making the iNUKE compatible with reliable overload protection Built-in either dual mono, stereo or mono bridge mode. Powerful remote software downloadable at behringer.com "Zero-Attack" limiters offer maximum output level with virtually... any source, balanced or unbalanced. iNUKE NU6000DSP NU3000DSP NU1000DSP NU6000 NU3000 NU1000 Front panel LCD display enables setup and adjustment without ...
Brochure
Page 3
... 2 x 880 Watts into 4 Ohms; 3000 Watts into 4 Ohms (bridge mode) and weighs less than 12 lbs / 5.5 kg iNUKE NU3000- iNUKE NU6000DSP/NU3000DSP/NU1000DSP Front Panel USB socket for laptop control and setup DSP LCD panel with reliable overload protection Value Sporting massive output ratings, lightweight..., an equally lightweight price tag, and Page 3 of 11 all the amenities a professional audio engineer could ask for, BEHRINGER iNUKE amplifiers are serious amps for computer Power button Rear Panel GAIN CONTROLS adjust input level Power Connection TWIST-LOCKING SPEAKER OUTPUTS accept...
... 2 x 880 Watts into 4 Ohms; 3000 Watts into 4 Ohms (bridge mode) and weighs less than 12 lbs / 5.5 kg iNUKE NU3000- iNUKE NU6000DSP/NU3000DSP/NU1000DSP Front Panel USB socket for laptop control and setup DSP LCD panel with reliable overload protection Value Sporting massive output ratings, lightweight..., an equally lightweight price tag, and Page 3 of 11 all the amenities a professional audio engineer could ask for, BEHRINGER iNUKE amplifiers are serious amps for computer Power button Rear Panel GAIN CONTROLS adjust input level Power Connection TWIST-LOCKING SPEAKER OUTPUTS accept...
Brochure
Page 4
iNUKE NU6000DSP NU3000DSP NU1000DSP NU6000 NU3000 NU1000 Built-in Subwoofer/Satellite crossover for perfect subwoofer operation Detented and illuminated gain controls for precise level setting Precise 4-segment Signal and Limit LEDs...buildup for reliable operation High-quality components and exceptionally rugged construction ensure long life Conceived and designed by BEHRINGER Germany Page 4 of 11 System configuration is a breeze thanks to iNUKE's Amp Remote software (Available on iNUKE DSP models only) Dynamic EQ combines the effects of equalization and side-chain compression to compensate for...
iNUKE NU6000DSP NU3000DSP NU1000DSP NU6000 NU3000 NU1000 Built-in Subwoofer/Satellite crossover for perfect subwoofer operation Detented and illuminated gain controls for precise level setting Precise 4-segment Signal and Limit LEDs...buildup for reliable operation High-quality components and exceptionally rugged construction ensure long life Conceived and designed by BEHRINGER Germany Page 4 of 11 System configuration is a breeze thanks to iNUKE's Amp Remote software (Available on iNUKE DSP models only) Dynamic EQ combines the effects of equalization and side-chain compression to compensate for...
Brochure
Page 11
...Group (music-group.com). This manual is not guaranteed. This information is supplied for market research purposes only and is part of 11 iNUKE NU6000DSP NU3000DSP NU1000DSP NU6000 NU3000 NU1000 NU1000 Output Power Maximum Output Power Stereo 8 Ω per channel, stereo 4 Ω per channel, stereo 2 Ω... 8 Ω >100 dB Continuously variable speed fan Back-to be made public in any description, photograph or statement contained herein. BEHRINGER is not to -front air flow Thermal and DC protection Stable into reactive or mismatched loads On/off muting, DC-fault power supply ...
...Group (music-group.com). This manual is not guaranteed. This information is supplied for market research purposes only and is part of 11 iNUKE NU6000DSP NU3000DSP NU1000DSP NU6000 NU3000 NU1000 NU1000 Output Power Maximum Output Power Stereo 8 Ω per channel, stereo 4 Ω per channel, stereo 2 Ω... 8 Ω >100 dB Continuously variable speed fan Back-to be made public in any description, photograph or statement contained herein. BEHRINGER is not to -front air flow Thermal and DC protection Stable into reactive or mismatched loads On/off muting, DC-fault power supply ...
Quick Start Guide
Page 1
(Check Out behringer.com for Full Manual) iNUKE NU6000/NU3000/NU1000 Ultra-Lightweight High-Density 6000/3000/1000-Watt Power Amplifier
(Check Out behringer.com for Full Manual) iNUKE NU6000/NU3000/NU1000 Ultra-Lightweight High-Density 6000/3000/1000-Watt Power Amplifier
Quick Start Guide
Page 2
...This also applies to defects caused by normal wear and tear, in order to comply with applicable technical or safety standards on BEHRINGER's website behringer.com under "Where to avoid 13. No user serviceable parts inside the enclosure - Do not use caution when moving the ...-A, Macau Finance Centre 9/J, Macau, including all other person (reseller, etc.) shall be performed only by applicable local laws. 2 iNUKE NU6000/NU3000/NU1000 Important Safety Instructions Terminals marked with this apparatus near any heat sources such as power supply cord or plug is required when ...
...This also applies to defects caused by normal wear and tear, in order to comply with applicable technical or safety standards on BEHRINGER's website behringer.com under "Where to avoid 13. No user serviceable parts inside the enclosure - Do not use caution when moving the ...-A, Macau Finance Centre 9/J, Macau, including all other person (reseller, etc.) shall be performed only by applicable local laws. 2 iNUKE NU6000/NU3000/NU1000 Important Safety Instructions Terminals marked with this apparatus near any heat sources such as power supply cord or plug is required when ...