... GmbH Frankfurter Ring 117, 80807 München Germany Tel.: 089-32 42 640 ALPINE ITALIA S.p.A. Tel.: 01908-61 15 56 ALPINE ELECTRONICS DE ESPANÃ, S.A. SPX-107R / SPX-137R / SPX-177R COMPONENT 2-WAY SPEAKER SYSTEM SYSTÈME DE HAUT-PARLEURS 2 VOIES SPX-17MB MIDBASS SPEAKER SYSTEM SYSTÈME À HAUT-PARLEURS DE GRAVES MOYENNES OWNER'S MANUAL Please...
... GmbH Frankfurter Ring 117, 80807 München Germany Tel.: 089-32 42 640 ALPINE ITALIA S.p.A. Tel.: 01908-61 15 56 ALPINE ELECTRONICS DE ESPANÃ, S.A. SPX-107R / SPX-137R / SPX-177R COMPONENT 2-WAY SPEAKER SYSTEM SYSTÈME DE HAUT-PARLEURS 2 VOIES SPX-17MB MIDBASS SPEAKER SYSTEM SYSTÈME À HAUT-PARLEURS DE GRAVES MOYENNES OWNER'S MANUAL Please...
Owners Manual
Page 21
... Q, 4e ordre Note: Network simulations above illustrate the effect of each filter upon the input signal, not the actual summed frequency response of the speaker system. Appendix A: SPX-177R Network Setting Specifications Electrical crossover pt: 3400Hz Acoustic crossover pt: 3800Hz (0 ) 2700Hz (30 ) 2250Hz (60 ) LPF: Low-Q 2nd order HPF: Low-Q 4th order Electrical... niveau disponibles. 21 de coupure acoust. 3800Hz (0 ) 2700Hz (30 ) 2250Hz (60 ) Filtre passe-bas Faible Q, 2e ordre Filtre passe-haut Faible Q, 4e ordre Fréq. SPX-177R Régl. 1 Régl. 2 Fréq.
... Q, 4e ordre Note: Network simulations above illustrate the effect of each filter upon the input signal, not the actual summed frequency response of the speaker system. Appendix A: SPX-177R Network Setting Specifications Electrical crossover pt: 3400Hz Acoustic crossover pt: 3800Hz (0 ) 2700Hz (30 ) 2250Hz (60 ) LPF: Low-Q 2nd order HPF: Low-Q 4th order Electrical... niveau disponibles. 21 de coupure acoust. 3800Hz (0 ) 2700Hz (30 ) 2250Hz (60 ) Filtre passe-bas Faible Q, 2e ordre Filtre passe-haut Faible Q, 4e ordre Fréq. SPX-177R Régl. 1 Régl. 2 Fréq.
Owners Manual
Page 25
...2250 Hz (60°) Filtre passe-bas Faible Q, semi-1er ordre Filtre passe-haut Méd. Tweeter response curves represent the different level settings available. SPX-137R Electrical crossover pt: 7000Hz Acoustic crossover pt: 3500Hz (0 ) 3150Hz (30 ) 2900Hz (60 ) LPF: Avg-Q Semi-2nd order HPF: Low.... Q, 2e ordre Note: Network simulations above illustrate the effect of each filter upon the input signal, not the actual summed frequency response of the speaker system. Q, 2e ordre Electrical crossover pt: 4000Hz Acoustic crossover pt: 2000Hz (60 ) LPF: Low-Q Semi-1st order HPF: Avg-Q 2nd order...
...2250 Hz (60°) Filtre passe-bas Faible Q, semi-1er ordre Filtre passe-haut Méd. Tweeter response curves represent the different level settings available. SPX-137R Electrical crossover pt: 7000Hz Acoustic crossover pt: 3500Hz (0 ) 3150Hz (30 ) 2900Hz (60 ) LPF: Avg-Q Semi-2nd order HPF: Low.... Q, 2e ordre Note: Network simulations above illustrate the effect of each filter upon the input signal, not the actual summed frequency response of the speaker system. Q, 2e ordre Electrical crossover pt: 4000Hz Acoustic crossover pt: 2000Hz (60 ) LPF: Low-Q Semi-1st order HPF: Avg-Q 2nd order...
Owners Manual
Page 28
... Q, 2e ordre Note: Network simulations above illustrate the effect of each filter upon the input signal, not the actual summed frequency response of the speaker system. SPX-107R Electrical crossover pt: 4000Hz Acoustic crossover pt: 3450Hz (0 ) 3200Hz (30 ) 3050Hz (60 ) LPF: Low-Q Semi-2nd order HPF:...2800Hz (30 ) 2500Hz (60 ) LPF: Low-Q Semi-1st order HPF: Med-Q 2nd order Régl. 1 Régl. 2 Fréq. Appendix C: SPX-107R Network Setting Specifications Annexe C : Spécifications des réglages du filtre - de coupure acoust. 2800 Hz (30°) 2500 Hz (60°) Filtre...
... Q, 2e ordre Note: Network simulations above illustrate the effect of each filter upon the input signal, not the actual summed frequency response of the speaker system. SPX-107R Electrical crossover pt: 4000Hz Acoustic crossover pt: 3450Hz (0 ) 3200Hz (30 ) 3050Hz (60 ) LPF: Low-Q Semi-2nd order HPF:...2800Hz (30 ) 2500Hz (60 ) LPF: Low-Q Semi-1st order HPF: Med-Q 2nd order Régl. 1 Régl. 2 Fréq. Appendix C: SPX-107R Network Setting Specifications Annexe C : Spécifications des réglages du filtre - de coupure acoust. 2800 Hz (30°) 2500 Hz (60°) Filtre...
Owners Manual
Page 29
... illustrate the effect of each filter upon the input signal, not the actual summed frequency response of the speaker system. Appendix C: SPX-107R Network Setting Specifications Annexe C : Spécifications des réglages du filtre - SPX-107R Electrical crossover pt: 2800Hz Acoustic crossover pt: 2000Hz (30 ) LPF: Low-Q Semi-2nd order HPF: Very...
... illustrate the effect of each filter upon the input signal, not the actual summed frequency response of the speaker system. Appendix C: SPX-107R Network Setting Specifications Annexe C : Spécifications des réglages du filtre - SPX-107R Electrical crossover pt: 2800Hz Acoustic crossover pt: 2000Hz (30 ) LPF: Low-Q Semi-2nd order HPF: Very...
Owners Manual
Page 34
... Frequency Response Sensitivity Net Weight SPX-177R 2-Way Component 75W/300W 4ohm 35-60 kHz 87dB 4.275 kg SPX-137R 2-Way Component 60W/240W 4ohm 40-60 kHz 86dB 3.965 kg SPX-107R 2-Way Component 40W/160W 4ohm 45-60 kHz 90dB 2.975 kg Drivers General Speaker size Speaker Type Power Handling (RMS) Frequency ... 75W/300W 4ohm 30-4 kHz 86dB 3.835 kg Système Modèle Type Puissance admissible (efficace/pointe) Impédance Réponse en fréquence Sensibilité Poids net SPX-177R Paire 2 voies SPX-137R Paire 2 voies SPX-107R Paire 2 voies 75 W / 300 W 4 ohms 35 Hz - 60 kHz 87...
... Frequency Response Sensitivity Net Weight SPX-177R 2-Way Component 75W/300W 4ohm 35-60 kHz 87dB 4.275 kg SPX-137R 2-Way Component 60W/240W 4ohm 40-60 kHz 86dB 3.965 kg SPX-107R 2-Way Component 40W/160W 4ohm 45-60 kHz 90dB 2.975 kg Drivers General Speaker size Speaker Type Power Handling (RMS) Frequency ... 75W/300W 4ohm 30-4 kHz 86dB 3.835 kg Système Modèle Type Puissance admissible (efficace/pointe) Impédance Réponse en fréquence Sensibilité Poids net SPX-177R Paire 2 voies SPX-137R Paire 2 voies SPX-107R Paire 2 voies 75 W / 300 W 4 ohms 35 Hz - 60 kHz 87...