Get support for Sharp XE-A202 - Electronic Cash Register

Sharp XE-A202 Support Question

Sharp XE-A202 Support Question

Find answers below for this question about Sharp XE-A202 - Electronic Cash Register.
Need a Sharp XE-A202 manual? We have 3 online manuals for this item!
Question posted by bdismang on July 6th, 2012

Error Code E-32

I get an e32 error code when I hit any key on the register. why is this?

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Sharp XE-A202 Manual Pages

XE-A202 Operation Manual in English and Spanish - Page 3

... English version. Never install the batteries into the interior of the cash register will lead to discoloration or deterioration of the SHARP Electronic Cash Register, Model XE-A202. Otherwise, distorted memory contents and malfunction of the register and cause component failure. • When cleaning your register in a location that the the positive (+) and negative (-) poles of each...
XE-A202 Operation Manual in English and Spanish - Page 4

... ...5 5 Displays ...6 6 Drawer Lock Key ...6 GETTING STARTED...7 FOR THE OPERATOR OVERVIEW OF FLOW OF DAILY SALES ENTRIES 11 BASIC SALES ENTRY ...12 1 Basic Sales Entry Example ...12 2 Error Warning ...13 3 Item Entries ...14 Single item entries ...14 Repeat entries ...15 Multiplication entries ...15 Split pricing entries ...16 Single item cash sale (SICS) entry 17...
XE-A202 Operation Manual in English and Spanish - Page 5

...key 38 4 Text programming ...39 ADVANCED PROGRAMMING ...44 1 Register Number and Consecutive Number Programming 44 2 Electronic...66 10 Before calling for service ...67 Error code table ...67 SPECIFICATIONS ...68 MANUAL DE ...32 1 Department Programming ...32 2 PLU (Price Look-Up) and Subdepartment Programming 33 3 Miscellaneous Key Programming ...35 % & V Rate for and 36 % & -
XE-A202 Operation Manual in English and Spanish - Page 7

... key %1 %2 Percent 1 and 2 keys RFND Refund key Discount key DEPT SHIFT Department shift key CLK# Clerk code entry key ~ 17 1 32 16 Department keys #/TM Non-add code/Time display SBTL /Subtotal key CA/AT/NS Total/Amount tender /No sale key 5 X1/Z1: To take the X/Z report for various daily totals X2/Z2: To take flash reports. For details, refer to register...
XE-A202 Operation Manual in English and Spanish - Page 8

...When you have registered ten times, the... state symbols : Appears during programming. : Appears when an error is detected. : Appears when the subtotal is displayed or ... eighth and ninth places at the timing of key entry when the electronic journal (EJ) memory is full. (Depending on... 5 Displays Operator display PLU/SUB DEPT REPEAT Clerk code Customer display (Pop-up type) RCPT OFF DC SHIFT...
XE-A202 Operation Manual in English and Spanish - Page 14

... can omit this order.) The clerk code 1 is opened. 8. Enter your clerk code. (For example, clerk code is the same as the subtotal.) A 7. For operation details, please refer to department 32, press the key first before pressing the department key. Clerk assignment 1 L 2. Tax status (T1: taxable 1) Total quantity Total amount Cash tendering/amount received Change 12 Repeat...
XE-A202 Operation Manual in English and Spanish - Page 15

... (treated as a cash sale. 13 Clear the error state by pressing the key and take proper action. Contact your register goes to save mode, it can disable receipt printing in the REG mode. If you can be necessary when the same clerk handles the next transaction. ■ Sign-on clerk code Clerk code 1 to finalize the...
XE-A202 Operation Manual in English and Spanish - Page 16

... by a code entry. To use PLU entries, their preset unit prices should belong to a department to 32, enter a unit price, press the key and press a department key. Group attributes, such as taxable status, are applied on items when they are entered to subdepartment mode for a merchandise classification. Dept. The cash register is preset, your cash register will finish...
XE-A202 Operation Manual in English and Spanish - Page 24

... of department 33 to 32, enter the refund amount and press the key, then press the D key and press the corresponding department key (when using the preset price, omit entering the amount). The cash register will print it at any point during the entry of 16 digits, at once. s To enter a non-add code number, enter the...
XE-A202 Operation Manual in English and Spanish - Page 35

...code is entered. key A *To program departments 17 through 32, press the department shift key at this programming entry. 2 PLU (Price Look-Up) and Subdepartment Programming The PLU function allows speedy key entries whereby a price is automatically called up when a code is entered. Key...SICS and sign). The cash register is preprogrammed so all 1200 codes are possible. Example: ...
XE-A202 Operation Manual in English and Spanish - Page 43

... "List of function texts" shown on the following page. 41 key To keep the current setting s 3 P @ *Function no. (max. 2 digits) Character keys (max. 8 digits) sA To program another dept. *To program departments 17 through 32, press the department shift key. code (1 to PLU1) Print Text programmed for PLU code 1 Function text To keep current setting Character...
XE-A202 Operation Manual in English and Spanish - Page 51

.... (For EJ 49 programming, please refer to program minus dept. unit price is selected. Other programming Job code: 61 * Item: A B C D E F G H Selection: Entry: Always enter 0. (Fixed position) 0 Always enter 0. (Fixed position) 0 Minus dept. Error beep activation Key touch sound availability Buffered keyboard Void mode operation availability Void mode entry data print in Z2 reports...
XE-A202 Operation Manual in English and Spanish - Page 59

...switch to the appropriate position referring to @ key: Amount of cash in the reports. • To stop reading...need to 16; code Key operation d : Department sales total Flash report: (Only display) ! < For dept. 1 to clear the register's memory. After ... It does not affect the register's memory. • Use the resetting function (Z) when you need to 32; ! < Dept. You ...
XE-A202 Operation Manual in English and Spanish - Page 69

... entered. Make a preset price entry. Make an open price entry is inhibited. Error code E01 E02 E03 E07 E11 E12 E32 E34 E35 E36 E37 E67 Error status Registration error Misoperation error Undefined code is full (in the void mode. 67 Enter a correct code a Program the key within a limit of the machine. The preset price entry is inhibited. Action...
XE-A202 Operation Manual in English and Spanish - Page 107

... whether based on contract, negligence, strict liability or otherwise. LIMITED WARRANTY SHARP ELECTRONICS CORPORATION warrants to the first consumer purchaser that this Sharp brand product (the "...to purchasers by anyone other than an authorized servicer. Your Product: XE series Electronic Cash Register Warranty Period of this limited warranty, the purchaser should follow the ...
Quick Installation Guide - Page 3

... to finalise. #/TM/ST REG OPX/Z MGR X1/Z1 X2/Z2 PGM Mode Lock TL/NS code DEPT# Unit price (max. key 12 Digit Name For example to program department 1 as food. • Ensure the Mode Lock ...• Press the #/TM/ST key followed by . X1/Z1 X2/Z2 The cash register has thirty two department buttons in white through 32, press the department shift key. REG OPX/Z MGR X1/Z1 ...
Service Manual - Page 1

... to be used for maintaining the safety of the set . CAUTION TO BE USED WHEN CONNECTING THE RS-232 CABLE 16 CHAPTER 8. q SERVICE MANUAL CODE : 00ZXEA202USME ELECTRONIC CASH REGISTER MODEL XE-A202 (U and A version) CONTENTS CHAPTER 1. SPECIFICATIONS 1 CHAPTER 2. TEST FUNCTION 12 CHAPTER 6. HARDWARE DESCRIPTION 6 CHAPTER 5. The contents are important for after sales service only...
Service Manual - Page 2

... (max.) 0°C~40°C (32°F to 104°F) 3. RATING Weight Dimensions Power source Power consumption Working temperature XE-A202 16.3lb (7.4kg) 13.0 (W) x 16.9 (D) x 11.0 (H) inches (330 (W) x 428 (D) x 280 (H) mm) AC 120V (m10%), 60Hz Stand-by inserting one of the two supplied mode keys - sKey names KEY TOP 2 RA RCPT/PO VOID ESC CONV %1, %2 RFND...
Service Manual - Page 4

...CASH, CHECK, CHARGE key o C: Light up whenever the foreign amount appears in the display. L: L: Decimal Point Decimal point TAB EJ near full Display position 7-1 4-1 8, 9 Description (by PGM selection). EJ FULL Low Battery No Battery Display position 1-8 2-10 8-10 10 10 10 10 10 9-10 7-10 8 9 2, 3 8-10 10 10 Description -: Floating Exx:xx = error code... 0.167 XE-A202U SPECIFICATIONS...
Service Manual - Page 13

... DISPLAY BUZZER TEST 1 Key operation 100 RCPT/PO 2 Test procedure Display at front side 4.5.6.7.8.9.0. 2) KEY CODE 1 Key operation 101 RCPT/PO 2 Test procedure Display KEY CODE 3 Check that: KEY code: Every time a key is pressed, the code of that key is normal. 4 End ... the test mode by pressing any key. B) The brightness of completion print XE-A202U TEST FUNCTION - 12 -

Similar Questions

Ask a New Question
Use the box below to post a new question about this Sharp product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Sharp Manuals

Find free Sharp XE-A202 - Electronic Cash Register manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Sharp Reviews

View thousands of Sharp user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Sharp customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Sharp customer service rankings, employee comments and much more from our sister site.