Get support for Sharp CV10NH - 10,000 BTU Portable Air Conditioner

Sharp CV10NH Support Question

Sharp CV10NH Support Question

Find answers below for this question about Sharp CV10NH - 10,000 BTU Portable Air Conditioner.
Need a Sharp CV10NH manual? We have 1 online manual for this item!
Question posted by Stordanmas on August 12th, 2013

Sharp Portable Air Conditioner Cv-p10rc Won't Drain

The person who posted this question about this Sharp product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Sharp CV10NH Manual Pages

CV-10NH Operation Manual - Page 3

...E-3 • PRECAUTIONS E-4 • LOCATION E-7 • INCLUDED E-7 • PART NAMES E-8 • INSTALL WINDOW PANEL E-10 • INSTALLATION AND REMOVAL OF EXHAUST HOSE .........E-14 • PRE-OPERATION CHECKS E-16 • COOL MODE E-18 •... ENGLISH This manual explains the proper use of your new air conditioner. Please read this manual carefully before using the product.
CV-10NH Operation Manual - Page 4

... TO WRITE: For service problems, warranty information, missing items and other assistance: Sharp Electronics Corporation Customer Assistance Center 1300 Naperville Drive Romeoville, IL 60446-1091 TO ACCESS...number, date of purchase, your complete mailing address (including zip code), your nearest Sharp Authorized Servicer) PARTS (for reporting loss or theft, please record below the model and...
CV-10NH Operation Manual - Page 5

... for the Sealed Cooling System parts; Nor shall Sharp be the sole and exclusive remedy available to Obtain Service: CV-10NH Portable Air Conditioner. The warranty period continues for a total of ...original container, will be free from defective workmanship and materials, and agrees that this Sharp brand product (the "Product"), when shipped in -home service for this Product: Additional...
CV-10NH Operation Manual - Page 6

...replaced with the proper amp rating. NOTE Radio or TV Interference If this room air conditioner should cause interference to radio or television reception, try to correct the interference by...receiving antenna. • Increase the separation between the room air conditioner and radio/TV receiver. • Connect the room air conditioner into an outlet on a circuit different from the product ...
CV-10NH Operation Manual - Page 7

...plug can cause electrical shock or equipment damage. • Drainage should be performed whenever moving the air conditioner. (See Page 26) If any water remains in the tank, it may spill out while ... during dehumidification mode. Water can result in the risk of electric shock. The drained water may spill out into the room. • The temperature around the drainage hose must...
CV-10NH Operation Manual - Page 8

... that blown out will enter the room from the Exhaust air outlet, but this case, perform drainage to drain out water within the unit. (See page 26) OPERATING CONDITIONS • The air conditioner must remove the heat produced by the unit outside through any lights or appliances that keeps the compressor turned off unnecessary...
CV-10NH Operation Manual - Page 9

... has casters to roll the unit over objects. • The unit must be rolled on carpet surfaces. Tape measure or ruler 3. ENGLISH LOCATION • The air conditioner should only be placed within reach of a properly rated grounded socket. • Never place any obstacles around the...
CV-10NH Operation Manual - Page 10

... signal receiver 4 window 5 5 POWER Button 6 6 OPERATION Lamp (red) 7 7 TIMER Lamp (orange) 8 9 8 MEGA COOL Lamp (green) 9 9 Air inlet 9 REAR VIEW 0 0 Exhaust air outlet q q Window exhaust adapter w w Exhaust hose e e Remote control hook r t r Air filters y t Drainage nozzle and stopcock y Power supply cord hooks u Drainpipe nozzle and stopcock u i Power supply...
CV-10NH Operation Manual - Page 12

... guard "A" 2 Attach the guard combined above to the window panel Push the insect guard net firmly to the window 22"~ 24" stool with 2 screws. E-10 Cut Window panel Window stool net Side "A" will be at the top, as the window. (2) Open the window sash and place the window panel on...
CV-10NH Operation Manual - Page 14

... the window is installed in the diagram, when it to the window frame with 2 screws. INSTALL WINDOW PANEL Installation in a sliding sash window (See page 10 for installation in the insect guard net. Insect guard net Hole Projection 2 Attach the guard combined above to the insect guard net. Insert all three...
CV-10NH Operation Manual - Page 18

.... 3 Press the TEST button. The circuit breaker is activated, power is supplied, and the air conditioner is functioning correctly. 4 Press the RESET button until you hear another CLICK. RESET TEST TEST ...; If you will hear a CLICK if the circuit breaker is now ready for use the air conditioner if the above procedure cannot be using a thin pointed implement. Disconnect the power plug and ...
CV-10NH Operation Manual - Page 21

...MODE button to monitor the water level in the container and empty as necessary. Drainage nozzle Stopcock "OPEN" position 4 Attach the drain grommet to a standard commercially-available hose. (5/8" inner diameter, 7/8" outer diameter) 5 Attach the hose to slightly drop the ...with container, the unit generates heat during operation. In this mode, the air conditioner dehumidifies the room.
CV-10NH Operation Manual - Page 22

... be set the desired fan speed. • Although the louvers are closed and no air blows 3 out into the lower drainpipe nozzle and that the stopcock is covered with the... VENT mode. FAN MODE In this mode, the air conditioner ventilates the air to outdoors. VENTILATION MODE In this mode, the air conditioner simply circulates the air without cooling it. QUIET LOW HIGH TO TURN OFF...
CV-10NH Operation Manual - Page 23

... in the COOL mode with the fan speed set automatically when operated the next time. Condensation may result. NOTE • During VENTILATION mode, UP/DOWN air flow direction cannot be set to malfunction when the remote control is used for an extended period of time. Vertical louvers CAUTION Never attempt...
CV-10NH Operation Manual - Page 24

... unit. ONE-HOUR OFF TIMER When the ONE-HOUR OFF TIMER is set, the unit will turn off . MEGA COOL OPERATION In this operation, the air conditioner fan works at the formerly set condition. • If you wish to operate the unit for another hour before the ONE-HOUR OFF TIMER is...
CV-10NH Operation Manual - Page 26

... the remote control display the next time you set the OFF TIMER or ON TIMER. • The OFF TIMER and ON TIMER can set from 10 to a maximum of 12 hours.
CV-10NH Operation Manual - Page 28

...The water will take about one minute. 4 Remove the hose from the drainage nozzle. 4 Attach the drain grommet to a standard commercially available hose. (5/8" inner diameter, 7/8" outer diameter) Stopcock "OPEN" position...the TIMER, OPERATION and MEGA COOL lamps are blinking. (This indicates that may be drained out is removed, a small amount of water that the water tank inside the unit ...
CV-10NH Operation Manual - Page 29

... for a long time"). 2 Operate the unit in poor cooling performance. Never operate the unit without the filter. Insect guard net MAINTENANCE AFTER AIR CONDITIONER SEASON 1 Perform drainage to drain out water within the unit. (See Page 26 "When the unit is clogged with dust. CLEANING THE FILTERS If the filter is...
CV-10NH Operation Manual - Page 30

No air will not be drained. (See page26) • Check the power plug. (See page16) AIR CONDITIONER DOES NOT COOL PROPERLY • Is it set to FAN, ...the hose as short as possible. This is sound of running drainage pump inside the unit. • This air conditioner evaporates water condensed during operation. BEFORE CALLING FOR SERVICE If the unit appears to be heard when the unit is...
CV-10NH Operation Manual - Page 60

TH 1 ESPAÑOL SHARP ELECTRONICS CORPORATION Sharp Plaza, Mahwah, New Jersey 07430-2135 U.S.A SHARP CORPORATION S-31 Printed in Thailand TINSEA541JBRZ 07M-

Similar Questions

Replacement Window Exhaust Unit For Sharp Portable Air Conditioner Model Cv-10nh
Do you have a replacement window exhaust kit available for sharp portable air conditioner model cv-1...
(Posted by jnohner18 2 years ago)
My Sharp Cv-10nh Portable Air Conditioner Leaks.
Whay does my Sharp CV-10NH portable air conditioner leak? The unit continues to operate, np lights b...
(Posted by bettycrockerus2 12 years ago)
Ask a New Question
Use the box below to post a new question about this Sharp product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Sharp Manuals

Find free Sharp CV10NH - 10,000 BTU Portable Air Conditioner manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Sharp Reviews

View thousands of Sharp user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Sharp customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings