Get support for Hunter 44860

Hunter 44860 Support Question

Hunter 44860 Support Question

Find answers below for this question about Hunter 44860.
Need a Hunter 44860 manual? We have 2 online manuals for this item!
Question posted by Anonymous-95800 on January 25th, 2013

Which Wires Do You Use To Install The Hunter44860 With A Goodman Gds8 Unit?

The person who posted this question about this Hunter product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Hunter 44860 Manual Pages

Owner's Manual - Page 2

Touchscreen Programmable Thermostat Model 44860 2 Stage Heat/2 Stage Cool installation and operation manual
Owner's Manual - Page 3

... 4 INSTALLATION PROCEDURES 4 GENERAL OPERATING INSTRUCTIONS 21 DATE & TIME SETTINGS 22 SYSTEM SETTINGS MENU 27 USER SETTINGS MENU 31 TEMPERATURE RANGE 34 ENERGY STAR DEFAULT PROGRAMS 35 MANUAL OPERATION 36 PROGRAM OPERATION 39 PROGRAM OVERRIDES 46 ADDITIONAL FEATURES 56 CLEAN SCREEN 56 CHANGE FILTER 60 ENERGY MONITOR FUNCTION 64 TROUBLESHOOTING 68 WIRING DIAGRAMS...
Owner's Manual - Page 4

Please read this manual before beginning installation and save this booklet for choosing a Hunter programmable thermostat. Your new Hunter thermostat will provide years of reliable service and year-round energy savings. 44002-01 r051807 Touchscreen Programmable Thermostat Model 44860 2 Stage Heat/2 Stage Cool Congratulations! Thank you for complete operating instructions. 
Owner's Manual - Page 5

...and two wall anchors for mounting. To install your new thermostat, you have, please contact a qualified HVAC Technician for assistance. IMPORTANT INFORMATION This thermostat is designed to work on the following ... Pumps Gas, Electric or Oil Systems Millivolt Systems 2-wire Hydronic Systems AC or Hard-wired This thermostat is not designed for use with 110V/220 V systems. If you are unsure...
Owner's Manual - Page 6

RC Y G W RC Y G W w NOTICE OF CAUTION! DO NOT disconnect the wires from the existing thermostat before reading these instructions. The wires must be labeled prior to removal to ensure proper connection. 44002-01 r051807 
Owner's Manual - Page 8

...turn off the power to the existing thermostat before removal could damage your system.) 2. Remove the existing thermostat cover to access the wires from the wall. (Some thermostats may be removed or disengaged.) 3. ... wires and mounting screws.) 4. Some models may want to secure the wires to the HVAC system OFF at the main power panel or at the existing thermostat. Do not let the wires...
Owner's Manual - Page 10

... chart. If wires marked "Y" or "C" are not labeled, contact a qualified HVAC technician. 5. Using the provided stickers, label each wire according to the existing terminal designation for proper identification. If there is no "C" wire, the thermostat will run on battery power. 44002-01 r051807  therefore, wire color should be a Common wire and provides 24 VAC power to the unit.
Owner's Manual - Page 11

... marked: CONVENTIONAL HVAC SYSTEMS label the wire with this sticker: if your existing thermostat is marked: label the wire with this sticker: Y1 / Y2 Cooling Stage 1 or 2 Y1 Y2 Y2 Y1 R/RC R / RC Cooling Transformer Power Supply ...24 VAC Common (if available) C G G Fan G RH RH Heating Transformer Power Supply RH See pages 72-73 for a complete wiring diagram. 10 44002-01 r051807
Owner's Manual - Page 12

... marked: HEAT PUMP SYSTEMS label the wire with this sticker: if your existing thermostat is marked: label the wire with this sticker: Y1 / Y2 Compressor Stage 1 or 2 Y1 Y2 Y2 Y1 C 24 VAC Common C C O W2 ... E R/RC R / RC 24 VAC Power Supply R/RC B B Heat Mode Powered Reverse Valve B L L System Monitor L See pages 74 for a complete wiring diagram. 44002-01 r051807 11
Owner's Manual - Page 14

If the existing holes do not match those on the wall horizontally and pull the labeled wires through the opening. 3. Position the new wall plate on the Hunter thermostat wall plate or, if there are no existing holes, visually level the wall plate and mark the wall for two holes. 44002-01 r051807...
Owner's Manual - Page 16

... opening. Securely tighten both screws. 44002-01 r051807 15 4. Tap the plastic anchors into the anchors. Reposition the wall plate on the wall, pulling the wires through the wall plate and into the holes until they are flush with the wall. 6. Remove the wall plate from the wall and drill two...
Owner's Manual - Page 17

Terminal Shield Terminal Screw Jumper Wire 16 44002-01 r051807
Owner's Manual - Page 20

... electrical panel and/or furnace. 44002-01 r051807 19 Press the thermostat to the wall plate and it over the terminal and battery openings. If the thermostat does not snap into place easily, the unit may damage the terminal pins. Place the thermostat over the wall plate, aligning it will snap into the back...
Owner's Manual - Page 22

... and airflow to settings that responds to the pressure of the thermostat is easy to program and use the pre-programmed default settings. The front of a finger. You can also operate the thermostat manually. 44002-01 r051807 21 GENERAL OPERATING INSTRUCTIONS Your new Hunter thermostat is a touch screen that you choose or you can...
Owner's Manual - Page 28

... SPAN (not available on page 26): 2F (1F, 2F, 3F) 4. AUTO SEASON SPAN: 5F (3F, 4F, 5F, 6F) 6. SYSTEM SETTINGS MENU The installer can set SYSTEM functions once the thermostat is CONVENTIONAL with (HEAT PUMP) as a second option. The default settings are listed inside the parentheses. SYSTEM: CONVENTIONAL (CONVENTIONAL, HEAT PUMP) 2. RESIDUAL...
Owner's Manual - Page 35

By using the preprogrammed and default settings, this thermostat can save you money by optimizing energy usage in heating and cooling. 30o F (0o C) 45o F (7o C) 95o F (35o C) 99o F (37o C) Out of Range "LO" 99o F 34 44002-01 r051807 TEMPERATURE RANGE This thermostat meets ENERGY STAR guidelines for energy efficiency.
Owner's Manual - Page 63

... weak, the CHANGE BATTERIES warning flashes until new batteries are installed. The system remains off . If the batteries become too weak for normal operation, the thermostat enters the second battery power shortage mode. When no battery power is left, the BATTERIES USED UP warning flashes on the display and the system turns off...
Owner's Manual - Page 68

See page 27. 44002-01 r051807 67 COMPRESSOR PROTECTION After the system stops running in cooling mode, there is a 3.5 minute delay before it can be restarted to prevent compressor damage due to YES. RESETTING THE UNIT To restore the thermostat to the original factory settings, enter the SYSTEM SETTINGS MENU and set Option 12 to rapid cycling.
Owner's Manual - Page 70

... the furnace blower door is installed between the RC and RH terminals. 6. If your system has 4 wires, ensure the jumper is closed properly. 5f. The display comes on or off. 5a. Replace batteries. 7. Replace batteries. 5e. Make sure the thermostat is enough power to protect the compressor. 5c. Replace unit. 44002-01 r051807 69...
Owner's Manual - Page 71

Refer to page 66 for ERROR mode instructions. If ERR message remains after battery replacement, then replace unit. 9. Manual operation instructions begin on page 38. 70 44002-01 r051807 How do I just operate my thermostat manually? 9a. The touch screen permanently reads SYSTEM ERROR. 8a. 8.

Similar Questions

Hunter Wiring Diagram For Mod.44860
The heat mode will not go on. Please send proper wiring diagram.
(Posted by danmaria133 10 years ago)
The Air Conditioning Will Not Turn On.
We just installed a new Hunter 40135 thermostat. The heat turns on but the airconditioner doesn't. W...
(Posted by diaza 10 years ago)
Ask a New Question
Use the box below to post a new question about this Hunter product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Hunter Manuals

Find free Hunter 44860 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Hunter Reviews

View thousands of Hunter user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Hunter customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Hunter customer service rankings, employee comments and much more from our sister site.

Hunter Recalls

Find comprehensive Hunter recall information updated hourly on RecallOwl.com.