Hunter 44550 Support Question
Find answers below for this question about Hunter 44550.Need a Hunter 44550 manual? We have 2 online manuals for this item!
Question posted by amjk on March 21st, 2014
How To Reset Hunter 44550 Thermostat
The person who posted this question about this Hunter product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.
Current Answers
There are currently no answers that have been posted for this question.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Related Hunter 44550 Manual Pages
Owner's Manual - Page 3
Thank you require further assistance, call Hunter Technical Support at 901-745-9222 from 8 a.m. Central Time. Please read this manual for complete instructions on installing and operating your thermostat will provide years of use.
By saving energy, your thermostat. Model Information: Model Number ____4_4_5_5_0 Serial Number Date Purchased Where Purchased If you for itself...
Owner's Manual - Page 4
Table of Contents
INTRODUCTION INSTALLATION
PROGRAMMING
OPERATIONS
Read This Before Installing Thermostat Features
What You Need Remove Old Thermostat Wire Labeling Mount Wallplate and Thermostat Selector Switches
Setting Time and Day Auto Programming Personal Program Schedule Manual Programming Weekday / Weekend Programming 7-Day Programming Reviewing Programs Reviewing the Current Temperature ...
Owner's Manual - Page 6
... to the set temperature will be displayed on the LCD, and the Cooling system will also operate single-stage heat pumps that this thermostat is programmed at your Hunter Thermostat. Press Auto Program to load the built-in the United States. It does not provide a delay when there are power outages. "LO" will...
Owner's Manual - Page 7
... normal, but can be away from an energy saving program to the Selector Switches information on several minutes prior to change the batteries and keep thermostat's clock and program settings. NOTE: If you replace the old batteries with the current time. When this condition, there is shut down, and your comfort...
Owner's Manual - Page 8
... Switch: System selector switch for the day.
Soft-touch programming keypad, see details below.
HOME TODAY: Overrides energysaving program temperatures while you can program the thermostat to allow display viewing in the dark.
Battery Door: Frontaccess battery door allows easy battery changes. By monitoring your energy usage, you are at home...
Owner's Manual - Page 9
... settings. As an ENERGY STAR® Partner, Hunter Fan Company has determined that this programmable thermostat meets the ENERGY STAR® guidelines for reviewing and...resets filter counter to current program control from manual override or Home Today mode.
For entering hour of day. HOUR
PROG
PROG DAY
MIN
DAY
AUTO PROGRAM
HOLD CLEAR
FILTER RETURN
Automatically programs the thermostat...
Owner's Manual - Page 10
...(s) s Phillips Screwdriver s Hammer s Electric drill and 3/16" bit s Two 1.5 V (AA) size alkaline batteries
Remove Old Thermostat
CAUTION: Do not remove any wiring from existing thermostat before reading the instructions carefully.
INSTALLATION
10-11
What You Need
This thermostat includes two #8 slotted screws and two wall anchors for wires. s IMPORTANT! Again, look for mounting...
Owner's Manual - Page 11
... comply with label shown terminal shown
terminal points is
If the code letter on this hole so that thermostat. This wire provides electricity to complete the circuit. RH, R, VR or 4 24 Volt
RH
RH...Cool
RC
RC
RC
terminal, then connect the other wire to the W terminal to non-battery powered thermostats. Each of wires in wall is often no hot or cold air can be concerned about how ...
Owner's Manual - Page 12
... mounting screws provided into the holes until flush with those on the Hunter wallplate.
Then level for plastic anchors provided if your existing holes do...anchor and tighten. (See Figure 3.)
OB
RC G
Y/Y1 W RH
Figure 2 NOTE: 5-wire Systems
Figure 3
If your thermostat has one wire marked R or RH (4-wire system), then leave the jumper wire between the RH and RC terminals. s Reposition...
Owner's Manual - Page 14
... HE switch)
The factory position for this Hunter thermostat to control your system, the system type must be specified by selector switches on within a minute of the thermostat calling for Heat, change the switch position ...no auxiliary or emergency heat source), then slide the switch to OFF before removing the thermostat from the wall. There are also other systems. "HE" position is normal, ...
Owner's Manual - Page 15
... temperature mode. This change may be made without resetting the thermostat, and will not change the current time display and...temperature.
Refer to the ALT position.
A similar table is set to C° and press the reset button on the circuit board for a complete discussion of the thermostat with the EPA ENERGY STAR® Program. Table B
Switch SW 5 SW 6 SW 7 ...
Owner's Manual - Page 16
...Time and Day
Remove the mylar label covering the LCD display window before operating thermostat.
1 2 : 0 0 M T W Th F Sa Su SET TEMP
s Initial display after a ... will cycle through 24 hours.
s During time and day setting mode, the temperature and program displays will update after power-up or reset. Tap to Normal mode automatically.
8 9 : 4 3 M T W Th F Sa Su SET TEMP
AM
°C
PM
...
Owner's Manual - Page 17
...separate programs for each weekend day can have a different set of 4 programs.
Your Hunter thermostat is pre-programmed to meet the ENERGY STAR® guidelines for energy efficiency. During Auto...AM
°C
PM
H
88
AUTO COOL HEAT TEMP
°HC
s The thermostat will change as shown below. By setting your thermostat up 5°F (3°C) for two 8-hour periods during winter can reduce ...
Owner's Manual - Page 26
... room temperature falls below 68°F.
This Hunter patent pending feature allows you to occur when the appropriate temperature span has been reached.
Likewise, the thermostat will alternate between Heating and Cooling systems, ... in Home
Today mode until the first program of the day, the thermostat will select the lowest program temperature for today to be selected from your...
Owner's Manual - Page 29
Filter Monitor
Your thermostat also keeps a record of the number of usage. s To reset the Filter Monitor counter, depress FILTER for heat and cool reaches 500 hours,... as well. The display will return to normal mode, or you to exit immediately. The display will blink, and the counter will be reset to zero.
70
AUTO COOL HEAT TEMP
°HC
8 4 : 1 0 M T W Th F Sa Su SET TEMP
AM...
Owner's Manual - Page 30
... if HOLD/CLEAR is adjusted during the recovery process. 72. 7 I. OPERATION
Auto Recovery
Hunter's Auto Recovery feature meets the ENERGY STAR® guidelines for energy efficiency by the start ...would note the temperature difference between heat and cool (automatically or manually) then the thermostat will not operate if Permanent hold, Temporary hold or Home Today is pressed during...
Owner's Manual - Page 33
... confirm normal operation. Next,
use a paper clip to press the RESET button next to an unexpected battery problem, the thermostat will have recently replaced them. If Error Mode returns, please call Hunter Technical support at (901) 745-9222 for further information.
It will cut -off in Cool mode if the room temperature drops...
Owner's Manual - Page 34
Press RESET button with a small pin and hold in "HOLD" or "Home Today" modes. 3. Check that the thermostat is power to ensure there is not in for the correct day setting.
1. There...Check for two seconds.
1. Look for "AUTO" on the LCD display. Replace batteries. 6. The thermostat may be sure the jumper wire is in the AUTO mode. If the Heat and Cool program temperatures are close, then...
Owner's Manual - Page 35
... problems, call 901-745-9222 from 8 AM to be reprogrammed.
Problem (cont.)
Solution (cont.)
ERRATIC DISPLAY
1. Replace unit. THERMOSTAT PERMANENTLY READS "HI," "LO," OR "ERR-" AFTER PRESSING RESET BUTTON
1. IF UNIT CONTINUES TO OPERATE IN THE OFF POSITION 1. Press the RESET button once with a small pin and hold for technical assistance. Replace unit.
Similar Questions
Our Hunter 44550 Thermostat Does Not Maintain The Temperature And At Times Will
thermostat does not hold temperature and will fluctuate as high as 85 degrees in summer.
thermostat does not hold temperature and will fluctuate as high as 85 degrees in summer.
(Posted by Ncshrader 6 years ago)