Get support for HP StorageWorks 8/24 - SAN Switch

HP StorageWorks 8/24 Support Question

HP StorageWorks 8/24 Support Question

Find answers below for this question about HP StorageWorks 8/24 - SAN Switch.
Need a HP StorageWorks 8/24 manual? We have 44 online manuals for this item!
Question posted by sivathokala93 on March 17th, 2021

Tell Me The Procedure Of Factory Reset Hp Storage Works San Switch 8/24

The person who posted this question about this HP product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

Answer #1: Posted by Troubleshooter101 on March 18th, 2021 2:27 AM
This answer was accepted by the poster of the original question.
Troubleshooter101

Member since:
September 30th, 2015

Points: 2,927,030
1,110
points
1. Connect the serial console to the SAN switch (or director). (Default serial console settings: Baud rate â 9600, Data bits â 8, Parity â none, Stop bits -1, Flow control â none).

...
Re: password reset for 8/24 SAN Switch

  1. Start system.
  2. Recover password.
  3. Enter command shell.

https://community.hpe.com:443/t5/hpe-eva-storage/password-reset-for-8-24-san-switch/td-p/4538498?nobounce=


Thanks


Please respond to my effort to provide you with the best possible solution by using the "Acceptable Solution" and/or the "Helpful" buttons when the answer has proven to be helpful. Please feel free to submit further info for your question, if a solution was not provided. I appreciate the opportunity to serve you!
Troublshooter101

Related HP StorageWorks 8/24 Manual Pages

HP StorageWorks Fabric OS 6.1.0c release notes (5697-7680, September 2008) - Page 19

... be seen on one FC8-48 blade for the 8/8 SAN Switch, 8/24 SAN Switch, 8/40 SAN Switch or 8/80 SAN Switch. Fixed in Fabric OS 6.1.0a On a 8/80 SAN Switch, the system status LED does not flash amber/green when a power supply is exceeded. Fixed in Fabric OS 6.1.0a During storage failover/failback test with DLS ON does not immediately balance...
HP StorageWorks Fabric OS 6.1.0d release notes (5697-7681, September 2008) - Page 19

... OS 6.1.0a After repeatedly running bladedisable/enable on the 8/8 SAN Switch, 8/24 SAN Switch or 8/80 SAN Switch. Fixed in Fabric OS 6.1.0a When disabling/enabling a port, Port Fencing disables the port because the allowable number of the FICON CUP daemon (ficud). Fixed in Fabric OS 6.1.0a HP StorageWorks Fabric OS 6.1.0d release notes 19 Fixed in Fabric OS...
HP StorageWorks Fabric OS 6.1.0f release notes (5697-7837, November 2008) - Page 21

...0a During storage failover/...HP StorageWorks Fabric OS 6.1.0f release notes 21 Fixed in Fabric OS 6.1.0a During non-disruptive firmwaredownload, Ex_Ports may be seen on a 4/256 SAN Director. Fixed in Fabric OS 6.1.0a FCR matrix settings may get stuck at G_Port on the 8/8 SAN Switch, 8/24 SAN Switch or 8/80 SAN Switch. Fixed in a 8/40 SAN Switch and 8/80 SAN Switch...
HP StorageWorks Fabric OS 6.1.0g release notes (5697-7861, November 2008) - Page 21

...-48 blade for the 8/8 SAN Switch, 8/24 SAN Switch, 8/40 SAN Switch or 8/80 SAN Switch. Fixed in the Fabric OS 6.1.0a firmware release. Fixed in Fabric OS 6.1.0a FCR matrix settings may toggle, causing traffic disruption in Fabric OS 6.1.0a Ex_Port fails to 5.3 under certain conditions. Fixed in Fabric OS 6.1.0a HP StorageWorks Fabric OS 6.1.0g release notes...
HP StorageWorks Fabric OS 6.1.0h release notes (5697-7961, January 2009) - Page 23

... After repeatedly running bladedisable/enable on one FC8-48 blade for the 8/8 SAN Switch, 8/24 SAN Switch, 8/40 SAN Switch or 8/80 SAN Switch. Fixed in Fabric OS 6.1.0a HP StorageWorks Fabric OS 6.1.0h release notes 23 Fixed in single and dual backbone configurations. Fixed in Fabric OS 6.1.0a During storage failover/failback test with both 4-Gb and 8-Gb blades may be...
HP StorageWorks Fabric OS 6.1.1b release notes (5697-7838, March 2009) - Page 19

... HP 8/40 SAN Switch when using Integated Routing, the edge switch connected to the HP 8/40 SAN Switch must be used . Integrated routing Ports 16-47 on all switches in the 4/256 SAN ...HP StorageWorks The FR4-18i ships with port type discovery. FICON support The FC4-48 and FC8-48 port blades are not able to operate with Fabric OS 6.0 may not work when attached to M-EOS switches...
HP StorageWorks Fabric OS 6.1.x administrator guide (5697-0234, November 2009) - Page 26

... eight character limit. for HP c-Class BladeSystem, SAN Switch 4/32, 4/64 SAN Switch, SAN Switch 4/32B, 8/8 SAN Switch, 8/24 SAN Switch, 8/40 SAN Switch, 8/80 SAN Switch, 400 Multi-protocol Router admin 4/256 SAN Director and DC SAN Backbone Director admin (short name, DC Director) Password password password Changing default account passwords at login: 1. factory Changing password for admin...
HP StorageWorks Fabric OS 6.1.x administrator guide (5697-0234, November 2009) - Page 82

... this password only once. HP StorageWorks 4/8 or 4/16, 8/8 SAN Switch, 8/24 SAN Switch, 8/40 SAN Switch, 8/80 SAN Switch, Brocade 4Gb SAN Switch for HP p-Class BladeSystem, Brocade 4Gb SAN Switch for password recovery: afHTpyLsDo1Pz0Pk5GzhIw== Enter the supplied recovery password. Press ESC within four seconds after the message "Press escape within this procedure during a planned down...
HP StorageWorks Fabric OS 6.1.x administrator guide (5697-0234, November 2009) - Page 84

... password. NOTE: The passwd command only applies to the boot PROM password when it is rebooted. HP StorageWorks 4/8 or 4/16, 8/8 SAN Switch, 8/24 SAN Switch, 8/40 SAN Switch, 8/80 SAN Switch, Brocade 4Gb SAN Switch for HP p-Class BladeSystem, Brocade 4Gb SAN Switch for the switches listed in "Setting the boot PROM password with a recovery string" on the previously active (now standby...
HP StorageWorks Fabric OS 6.2.0g release notes (5697-0035, May 2009) - Page 43

... defects Closed defect summary Solution Brocade 8-Gb SAN Switch for HP BladeSystem c-Class requires up- Traffic Fixed in Fabric OS 6.2.0c Works 4/256 SAN Director. Fixed in Fabric OS 6.2.0d is... ISL links between the HP StorageWorks Encryption SAN Switch in an HA cluster environment while rekey operations are in progress may cause kernel panic on an HP Storage- Table 11 Fabric OS...
HP StorageWorks 8GB SAN Switch hardware reference guide (5697-0291, March 2010) - Page 13

... console port (RJ-45) 3. The enclosure uses forced-air cooling, with corresponding port status LEDs. To enable additional ports, you must purchase and install the HP Storage Works 8/8 and 8/24 SAN Switch 8-Gb 8-port Upgrade LTU (part number T5518A): • For the 8/8 SAN Switch-To enable ports 8 through 15, you must purchase and install one upgrade license.
HP StorageWorks 8GB SAN Switch hardware reference guide (5697-0291, March 2010) - Page 15

...additional ports, you must purchase and install the HP Storage Works 8/40 SAN Switch 8-Gb 8-port Upgrade LTU (part number T5519A): 8-Gb SAN Switch Hardware Reference Guide 15 Fibre Channel port status...Ethernet port LEDs (green/amber) 5. Activating additional 8/40 SAN Switch ports By default, the 8/40 SAN Switch model integrates 24 licensed ports (ports 0 through 23). System status (top)...
HP StorageWorks Fabric OS 6.2.0d release notes (5697-0353, March 2010) - Page 45

... in Fabric OS 6.2.0c Works 4/256 SAN Director. Fixed in Fabric OS 6.2.0c Internal recovery scheme can attempt to correct a valid Frame Redirection RAM Filter, which causes drives not to one initiator from the container. 3. This is 39o Celsius. Running configdefault may disappear when rebooting the HP StorageWorks Encryption SAN Switch that is using frame redirection...
HP StorageWorks Fabric OS 6.2.0e release notes (5697-0354, March 2010) - Page 49

... mode, as well as marginal/down on fully populated HP StorageWorks DC SAN Director. Enabled new SFP support in Fabric OS 6.2.0c HP StorageWorks 8/40 SAN Switch did not indicate a warning when Fixed in Fabric OS 6.2.0c Works 4/256 SAN Director. Updated serdes values are reported on an HP StorageWorks DC Switch Encryption Blade when the ambient temperature is 39o Celsius. Workaround...
HP StorageWorks 8Gb SAN Switch hardware reference manual (5697-7478, June 2008) - Page 15

...a second upgrade license. AC power inlet Figure 1 Port side view-8/8 and 8/24 SAN Switch Nonport side of the chassis through 7). To enable additional ports, you must purchase and install the HP Storage Works 8/8 and 8/24 SAN Switch 8Gb 8-port Upgrade LTU (part number T5518A): • For the 8/8 SAN Switch-To enable ports 8 through 15, you must purchase and install one upgrade...
HP StorageWorks 8Gb SAN Switch hardware reference manual (5697-7478, June 2008) - Page 17

...additional ports, you must purchase and install the HP Storage Works 8/40 SAN Switch 8Gb 8-port Upgrade LTU (part number T5519A): • To enable ports 24 through 31, you must purchase and install one ... FRUs in an N+1 configuration to import and export devices between fabrics, enabling selective device sharing while maintaining remote fabric isolation. Just like traditional FCR, Integrated...
HP StorageWorks 8Gb SAN Switch hardware reference manual (5697-7478, June 2008) - Page 23

Table 5 Optional software kits Option Part number HP StorageWorks Full Fabric Upgrade License T4261A HP Storage Works 8/8 and 8/24 SAN Switch 8Gb 8-port Upgrade LTU T5518A HP StorageWorks 8/80 SAN Switch 8Gb 16-port Upgrade LTU T5520A HP Storage Works 8/40 SAN Switch 8Gb 8-port Upgrade LTU T5519A Adaptive Networking AE493A Fabric Watch ISL Trunking A6515A A6516A Advanced Performance...
HP StorageWorks 8-Gb SAN Switch hardware reference manual (5697-8047, June 2009) - Page 18

... indicates that you purchase the HP StorageWorks Full Fabric Upgrade License, part number T4261A, to the port side. System RS-232 console port (RJ-45) 3. AC power inlet Figure 1 Port side view-8/8 and 8/24 SAN Switch Nonport side of the chassis through 15, you must purchase and install the HP Storage Works 8/8 and 8/24 SAN Switch 8-Gb 8-port Upgrade LTU (part...
HP StorageWorks 8-Gb SAN Switch hardware reference manual (5697-8047, June 2009) - Page 20

... fan FRUs in an N+1 configuration to import and export devices between fabrics, enabling selective device sharing while maintaining remote fabric isolation. To enable additional ports, you must purchase and install the HP Storage Works 8/40 SAN Switch 8-Gb 8-port Upgrade LTU (part number T5519A): • To enable ports 24 through 31, you must purchase and install one upgrade...
HP StorageWorks 8-Gb SAN Switch hardware reference manual (5697-8047, June 2009) - Page 32

... carton checklist Number 1 Description One accessory kit, containing the following items: • One set of HP StorageWorks product documentation, including HP Storage- See the HP StorageWorks SAN Switch Rack Mount Kit installation instructions for your particular switch SAN Switch Rack Mount Kit hardware and rail assemblies: • Two rear mounting brackets 2 • A right inner...

Similar Questions

Ask a New Question
Use the box below to post a new question about this HP product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

HP Manuals

Find free HP StorageWorks 8/24 - SAN Switch manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

HP Reviews

View thousands of HP user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete HP customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed HP customer service rankings, employee comments and much more from our sister site.

HP Recalls

Find comprehensive HP recall information updated hourly on RecallOwl.com.