Get support for HP ML350 - ProLiant - G6

HP ML350 Support Question

HP ML350 Support Question

Find answers below for this question about HP ML350 - ProLiant - G6.
Need a HP ML350 manual? We have 60 online manuals for this item!
Question posted by juanionl on October 15th, 2014

Ml350 G3 How To Replace Array Controller Cache Battery

The person who posted this question about this HP product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related HP ML350 Manual Pages

Microsoft Windows Event ID and SNMP Traps Reference Guide for use with SmartStart version 8.25 - Page 34

...replace the drive. SNMP Trap: cpqDa5AccelStatusChange - 3025 in CPQIDA.MIB Symptom: Physical Drive Status Change. This trap indicates that the agent has detected a change in the status of an array accelerator cache... Severity: Error (3) Event Title: Drive Array Accelerator Status Change. The current status is permDisabled(5), you may need to the array controller in slot %4, port %5, bay %6 ...
Microsoft Windows Event ID and SNMP Traps Reference Guide for use with SmartStart version 8.25 - Page 35

... power, that no data has been lost battery power. User Action: Replace the Accelerator Cache Board. If data was being stored in CPQIDA.MIB Symptom: Accelerator Board Battery Failed. This trap indicates that has lost . Log Message: The array accelerator board attached to the array controller in slot %4 is reporting a battery failure. Supporting SNMP Trap Data: • sysName...
Microsoft Windows Event ID and SNMP Traps Reference Guide for use with SmartStart version 8.25 - Page 43

...need to the external controller in the status of an External Channel Array spare drive. User Action: If the accelerator board status is failed, replace the drive. This ... Array Accelerator Status Change. SNMP Trap: cpqFca2AccelStatusChange - 16017 in CPQFCA.MIB Symptom: External Array Spare Drive Status Change. Log Message: The spare drive in the status of an Array Accelerator Cache ...
Microsoft Windows Event ID and SNMP Traps Reference Guide for use with SmartStart version 8.25 - Page 44

... accelerator board attached to the external controller in the accelerator memory when the system lost battery power. If data was being stored in I /O slot %5 of array "%4" is reporting that it contains bad cached data. Log Message: The array accelerator board attached to the external controller in I /O slot %5 of array "%4" is now [cpqFcaAccelStatus]." Supporting SNMP Trap Data: •...
Microsoft Windows Event ID and SNMP Traps Reference Guide for use with SmartStart version 8.25 - Page 67

... • cpqDaAccelTotalMemory Supporting SNMP Trap Description: "Battery status is reporting that the agent has detected a battery failure associated with the array accelerator cache board. Log Message: The array accelerator board attached to the array controller in %4 is reporting a battery failure. This trap indicates that it contains bad cached data. Supporting SNMP Trap Data: •...
HP ProLiant G6 Technology Overview - Page 5

... and enhanced features that a single battery can drive a single RAID array of two drives in order to upgrade the capacity or speed of DIMMs to create or expand a RAID array across the entire line of ProLiant G6 servers. The HP SAS Expander Card attaches to a Smart Array P410 or P410i (internal) controller through the steps to 200...
ISS Technology Update, Volume 8, Number 2 - Page 4

... to retain data up to 6 days of data cache retention. However, HP recommends replacing the battery pack every 3 years. However, high system temperature accelerates aging and decreases battery life. The battery pack is accelerated by the size of the cache. Battery aging is designed to provide 3 days of data cache retention at its rated capacity. In a worst case...
ISS Technology Update, Volume 9 Number 1 - Page 3

... permission of the IEC (see Legal Notices). For disk and file capacities, the latter remedy is the same as 536.9 MB. For example, reporting a Smart Array controller cache size of 512 MiB is preferable to reporting it is much easier to recognize that 300 GB is the same as 300,000 MB than...
ProLiant High Availability: The IT Imperative - Page 4

...ProLiant servers provide the availability required by permitting the failed fan to be changed while the system is written to cache memory and before it down and replace the failed fan. This helps to business operations. Smart Array controllers... 1+0 battery-backed cache, providing battery backup for servicing at higher flow impedances and a more information on ProLiant servers,...
HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheets - Page 124

... event time unknown HP SmartArray No Action required Name of the computer system generating the indication CreationClassName of the computer system generating the indication HP_AlertIndication Array Controller Cache Status changed to OK Contains a list of all the IP addresses of the computer system generating the indication SMX_OperatingSystem.OSType Operating system version of the...
HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheets - Page 126

...) 10 Time of the event or time of the indication if event time is set to a status of the computer system generating the indication HP_AlertIndication Array Controller Cache Status is unknown HP SmartArray No Action required Name of the computer system generating the indication CreationClassName of Temporarily Disabled. 4-4-16 HP_DeviceIndication...
HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheets - Page 127

...SystemFirmwareVersion SystemSerialNumber SystemProductID SystemModel SystemGUID ImpactedDomain BladeBay * BladeName * EnclosureName * RackName * RackUID * SystemVirtualSerialNumber SystemVirtualUUID Property implementation 35 (Performance Degraded) Array Controller Cache Status Changed to Temporarily Disabled Contains a list of all the IP addresses of the computer system generating the indication...
HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheets - Page 129

... ProbableCauseDescription NetworkAddresses OSType OSVersion ProviderVersion SystemFirmwareVersion SystemSerialNumber SystemProductID Property implementation Array Controller Cache Status is unknown HP SmartArray Check Cache controller error code. Controller has detected a problem with the cache and has disabled the cache permanently. Name of the computer system generating the indication...
HP ProLiant Servers Troubleshooting Guide - Page 93

... (Recharging) Description: Battery pack on One of the RAM Chips Description: Cache has been disabled due to a large number of ECC errors detected while testing the cache during POST. Board not Attached Description: An array controller is not connected. Replace if needed. Action: Try reseating the cache to array controller. If that does not work, replace the cache. Refer to recharge...
HP ProLiant Servers Troubleshooting Guide - Page 98

... Due to Cache Error Description: This logical drive failed due to less than 75% of Batteries at the sufficient voltage level. Action: Be sure both controllers are using ACU ("Array Configuration Utility" on the array accelerator is in the WRONG DRIVE REPLACED or LOOSE CABLE DETECTED state. Action: Replace the array accelerator board if the batteries do not recharge...
HP ProLiant Servers Troubleshooting Guide - Page 110

... installed on page 67). If the following versions are using array accelerators with another board type. Array Accelerator: This controller has been set up to be written to the controller. ADU is disabled because the batteries are disabled. Array Accelerator: The cache is being replaced by the ACU diagnostics feature ("Diagnostics tasks" on the server, see the messages...
HP ProLiant Servers Troubleshooting Guide - Page 148

... the problem persists, replace the cable, backplane, or Smart Array Controller. 1775-Slot X Drive Array - Drives in the original controller cache. Action: The SCSI bus is . 3. Be sure the cables to the specified port are attached correctly. Action: Check the file system to retry. Turn the system power off while checking the ProLiant power and cable connections...
Technology and architecture of HP ProLiant Intel-based 300-series G6 (Generation 6) servers - Page 1

...ProLiant Intelbased 300-series G6 (Generation 6) servers Technology brief Abstract...3 Introduction...3 Intel Xeon 5500 Series processor technology 3 Multi-level caches ...3 Integrated memory controller ...4 QuickPath Interconnect controller...Array and SAS/SATA technology 10 SAS-2 ...10 New generation HP Smart Array controllers 11 Battery backed write cache ...11 Zero Memory RAID...11 Smart Array...
Technology and architecture of HP ProLiant Intel-based 300-series G6 (Generation 6) servers - Page 11

... form factor, hardware, and firmware. With the exception of 2009, Smart Array controllers are capable of sending and receiving data simultaneously across all ProLiant 300-series G6 servers. Administrators can be upgraded to SAS and SATA devices. Smart Array Advanced Pack (SAAP) HP Smart Array Advanced Pack (SAAP) is required for communicating commands to 256 MB...
Technology and architecture of HP ProLiant Intel-based 300-series G6 (Generation 6) servers - Page 20

... certification of memory, array controllers, and drives in continuously analyzing and optimizing adaptive server infrastructure. VSE delivers four key capabilities for ProLiant servers assists users in...ProLiant Onboard Administrator powered by iLO 2 HP ProLiant Onboard Administrator powered by iLO 2, HP Insight Control Environment management suite, and HP Insight Dynamics - With ProLiant G6...

Similar Questions

Ask a New Question
Use the box below to post a new question about this HP product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

HP Manuals

Find free HP ML350 - ProLiant - G6 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

HP Reviews

View thousands of HP user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete HP customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed HP customer service rankings, employee comments and much more from our sister site.

HP Recalls

Find comprehensive HP recall information updated hourly on RecallOwl.com.