Get support for HP GbE2c - Blc Layer 2/3 Fiber SFP Option

HP GbE2c Support Question

HP GbE2c Support Question

Find answers below for this question about HP GbE2c - Blc Layer 2/3 Fiber SFP Option.
Need a HP GbE2c manual? We have 11 online manuals for this item!
Question posted by andy69ron on March 13th, 2014

Can Rmon Event Helps Us In Ufd Detection For Hp Gbe2c Blade Switches

The person who posted this question about this HP product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related HP GbE2c Manual Pages

HP BladeSystem c7000 Enclosure Maintenance and Service Guide - Page 23

a) HP GbE2c Ethernet Blade Switch for HP c-Class BladeSystem 414037-001 b) HP GbE2c Layer 2/3 Ethernet Blade Switch for c-Class BladeSystem* 438475-001 c) HP 10Gb Ethernet BL-c Switch* 447116-001 d) HP 1:10Gb Ethernet BL-c Switch* 438476-001 e) Brocade 4Gb SAN Switch for HP cClass BladeSystem, 12 ports* f) Brocade 4Gb SAN switch for HP cClass BladeSystem, 24 ports* 411120-001 411121-...
HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Application Guide - Page 8

... Spanning Tree Protocol" describes extensions to the Spanning Tree Protocol that connect to configure the RMON agent on the GbE2c Layer 2/3 Ethernet Blade Switch. • "Troubleshooting tools" describes Port Mirroring and other routers. This release provides Uplink Failure Detection and Virtual Router Redundancy Protocol (VRRP). This chapter also discusses different methods to configure the...
HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Application Guide - Page 10

... : [Main Menu] info stats cfg oper boot maint diff apply save revert exit - For more information, see the HP GbE2c Ethernet Blade Switch for collecting switch information and performing switch configuration. Telnet access provides the same options for users familiar with the switch, run the Telnet program on your workstation and issue the telnet command, followed by the...
HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Application Guide - Page 11

...RMON menu-Configure Remote Monitoring (RMON) functions. • Layer 3-Configure all of the IP related information, including IGMP Snooping. • QoS-Configure Quality of Service features. • Access Control-Configure Access Control Lists and Groups. • Uplink Failure Detection... For more information, see the HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Command Reference ...
HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Application Guide - Page 12

... Engineering Steering Group in the CLI: >> # /cfg/sys/ssnmp/snmpv3 For more details, see the HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Command Reference Guide. Authentication used is an enhanced version of the IP interfaces on the switch. username 2: adminsha/password adminsha. To configure an SNMP user name, enter the following command in March...
HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Application Guide - Page 16

... is similar to send) (Set the authentication level) For more information on using SNMP, see the HP GbE2c Ethernet Blade Switch for SNMPv3 traps, you specify the model, specify snmpv2 instead of the access table. Accessing the switch 16 SNMPv2 trap host configuration The SNMPv2 trap host configuration is not used by SNMPv3. Wherever you...
HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Application Guide - Page 17

... can set a source IP address (or range) that perform significant management functions across the Internet. See the HP GbE2c Ethernet Blade Switch for c-Class BladeSystem User Guide for a complete list of management information exchanged between the remote administrator and the switch. Secure access to a specific IP address range. When an IP packet reaches the application...
HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Application Guide - Page 30

... XConnect1 18 XConnect2 19 Mgmt 20 Uplink1 21 Uplink2 22 Uplink3 23 Uplink4 24 Uplink5 Ports and trunking 30 A trunk group is useful in the HP GbE2c Ethernet Blade Switch for the five external ports, two crosslink ports, and 16 server ports. For more information, see the port commands in understanding other trunk-capable...
HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Application Guide - Page 32

... the enclosure type. The trunk groups on either switch. however, trunk members can be monitored. For more information, see the HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Command Reference Guide. Ports and trunking 32 Port trunking example In this example, see the HP GbE2c Ethernet Blade Switch for c-Class BladeSystem User Guide. Figure 1 Port trunk group configuration example...
HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Application Guide - Page 110

... events or error conditions, such as follows: >> # /cfg/l3/ospf/aindex /areaid NOTE: The aindex option above parameters, you are configuring multiple areas in GbE2c software...Switch." OSPF 110 OSPF implementation in GbE2c software The GbE2c Ethernet Blade Switch supports a single instance of OSPF and up to 4 K routes on the switch. For more information, see "Virtual Links"). It also helps...
HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Application Guide - Page 140

... network topologies. This release provides information about Network Adapter Teaming on the GbE2c Layer 2/3 Ethernet Blade Switch. Uplink Failure Detection Uplink Failure Detection (UFD) is available only on HP ProLiant server blades, see the white paper at the following figure shows a basic UFD configuration, with a Failure Detection Pair (FDP) that consists of one LtM (Link to Monitor) and...
HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based Interface Guide - Page 125

... of 802.1x Enable/Disable Syslog of UFD Enable/Disable Syslog of CFG Enable/Disable Trap of UFD Description Enables or disables syslog messages and traps of Uplink Failure Detection (UFD) events. Enables or disables syslog messages of OSPF-related events. Enables or disables event traps of Remote Monitoring (RMON) events. Configuring the switch 125 Enables or disables syslog messages...
HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Command Reference Guide - Page 18

... pmirr - Apply and save - QOS Menu acl - Access Control List Menu rmon - Restore current configuration from FTP/TFTP server cur - Otherwise apply and save after the performing the "Optional Setup for HP c-Class Blade System. By default, they are not configuring the switch with administrator privileges. [Main Menu] info - After connecting, the login prompt displays...
HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Command Reference Guide - Page 72

... statistics: Table 57 IP statistics Statistics ipInReceives ipInHdrErrors Description The total number of input datagrams discarded due to errors in their IP options, and so on the GbE2c Layer 2/3 Ethernet Blade Switch. GEA Layer 3 statistics Command: /stats/l3/geal3/dump GEA L3 statistics: Max L3 table size Number of L3 entries used : 4096 : 9 Max LPM table...
HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Command Reference Guide - Page 92

...rmonufd Displays the current syslog settings. Enable the SCP apply and save on all the severity levels. Disable the SCP apply and save dis - This menu enables Secure Shell (SSH) access from any SSH client. The menu options do not display if you access the switch...based Interface (BBI). NOTE: See the HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Application Guide for ...
HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Command Reference Guide - Page 155

...alarm event index that is triggered when a rising threshold is used to configure, enable, and disable the monitored port. The range is from 0 to 65535. NOTE: See the "Troubleshooting tools" appendix in the HP GbE2c Ethernet Blade Switch for... of the mirrored and monitoring ports. Table 174 RMON Alarm Menu options Command sample abs|delta almtype rising|falling|either (rising or falling).
HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Reference Guide - Page 55

...on the GbE2c Layer 2/3 Ethernet Blade Switch. Command mode: All show interface port Displays Internet Protocol statistics for the port. Command mode: All Port Statistics The following table describes general Statistics commands. interface-counters Command mode: All show counters Dumps all statistics. Statistics commands Introduction You can execute the clear command option to...
HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Reference Guide - Page 83

... and executes commands in this SCP administrator is encrypted. NOTE: See the HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Application Guide for auto-generating the RSA server key. ...stg • vlan • ssh • ntp • ip • web • rmonufd Command mode: Global configuration Displays the current syslog settings. The value of zero (0) means the RSA ...
HP GbE2c Ethernet Blade Switch for c-Class BladeSystem ISCLI Reference Guide - Page 138

... 169 Port Mirroring Configuration commands Command port-mirroring monitor-port mirroring-port {in the HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Application Guide for information on a target port are duplicated and ...-mirroring Description Adds the port to be mirrored. Displays the current RMON Alarm parameters. Command mode: All except User EXEC Configuration Commands 138...
HP GbE2c Layer 2/3 Ethernet Blade Switch for c-Class BladeSystem User Guide - Page 10

...8226; MAC addressing • Physical medium transmission error detection • Medium allocation (collision avoidance) • Contention resolution (collision handling) Layer 2 switching technology allows the switch to look into an autonomous user group that appears as a single LAN. Redundant Ethernet signals from each blade server are routed through the enclosure backplane to separate...

Similar Questions

Ask a New Question
Use the box below to post a new question about this HP product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

HP Manuals

Find free HP GbE2c - Blc Layer 2/3 Fiber SFP Option manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

HP Reviews

View thousands of HP user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete HP customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed HP customer service rankings, employee comments and much more from our sister site.

HP Recalls

Find comprehensive HP recall information updated hourly on RecallOwl.com.