Electrolux EIED55HIW Support Question
Find answers below for this question about Electrolux EIED55HIW - 8.0 cu. Ft. Electric Dryer.Need a Electrolux EIED55HIW manual? We have 6 online manuals for this item!
Question posted by Stupiddryer on February 1st, 2014
How Do We Check The Heater Coils For E64 Code On Electrolux Dryer
The person who posted this question about this Electrolux product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.
Current Answers
There are currently no answers that have been posted for this question.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Related Electrolux EIED55HIW Manual Pages
Complete Owner's Guide (English) - Page 2
...; Dryer Settings Chart 14 Care & Cleaning 19 Solutions to customer satisfaction and product quality throughout the life of a relationship. 2 Finding Information
Please read and save this page to record important product information. To ensure our ability to continue serving you, please use this guide
Thank you for quick reference
Purchase date
Electrolux...
Complete Owner's Guide (English) - Page 5
...Failure to comply with local codes. Refer to a gas pipe. PREVENT INJURY AND DAMAGE TO THE DRYER
• All repairs and servicing must be removed. If the dryer is moving. Do not ... or store the dryer where it checked and reinstalled by a qualified service person in accordance with these warnings could occur.
• To prevent injury, do so can result in electrical shock or injury....
Complete Owner's Guide (English) - Page 7
.... This noise is normal and will only occur when the gas is
C
controlled by electric solenoids. Check and clean the lint screen. (See page 9.)
2. Start the dryer. (See page 9.)
Normal Operating Sounds
You may or may happen
if the dryer has not been in use for a period of
time, or after a heavy load has...
Complete Owner's Guide (English) - Page 8
... two or three similar items to prevent snagging and tangling.
2. Dry items of fire, electric shock or injury to persons, read the IMPORTANT SAFETY INSTRUCTIONS in washing. Place delicate or ... beginning of the Use and Care Guide before drying.
Load the dryer and close the door. Check that attract lint.
Dryer heat may not have been removed in this section of the cycle...
Complete Owner's Guide (English) - Page 16
... REL. The extended tumble option can be changed by repeating the my favorite procedure. Check fabric care labels to prevent damage caused by NSF International®, an independent, third...level and options will be indicated. An extended drying time at the end of Residential Clothes Dryers
Saving Favorites
To program a cycle with your preferred settings, select the desired cycle, drying ...
Complete Owner's Guide (English) - Page 20
... lint brush or roller to remove lint.
• Do not overload dryer. • Use fabric softener in
washer or dryer to reduce static electricity. • Remove items when they are slightly damp to avoid overdrying. • Check that lint filter is clean and in dryer after
cycle ends.
Rinse and rewash.
• Add a few bath...
Complete Owner's Guide (English) - Page 21
...Electrical power cord is not securely plugged Make sure the plug fits tightly in or plug may turn but won't heat. Call authorized service person for procedure.
of natural gas (gas models). Check to make sure supply valve is blown, the drum may be loose. Dryer... and expense. House fuse blown or circuit breaker tripped. Dryer runs but the heater will be 20% longer than two 90° bends ...
Wiring Diagram (All Languages) - Page 1
... with Contact
Sensor, replace Electronic Control Board. E64
Heater Open
Circuit
Check heater coils and connections for continuity. For Gas Model, also check Inlet Thermal Limiter for open circuit between L1 and motor relay connection (J3-2). If no wiring problems
found, replace Electronic Control Board. CAUTION: DISCONNECT ELECTRICAL CURRENT BEFORE SERVICING Please Return This Sheet to...
Wiring Diagram (All Languages) - Page 2
...Timer
Exhaust blocked; Within 10 seconds after pressing "cancel", press any load from the dryer and press "start pause" to enter standby mode and enable diagnostic entry. 2. ... Check vent restrictions and resistance values of Outlet Control Thermistor, and check wiring for open circuit. Replace console or Interface Board
defective
as appropriate
FACTORY RESET 1. Error Code
...
Wiring Diagram (All Languages) - Page 3
...(lights/Buttons Test). BARS"
3
Motor Clockwise (CW)
Check Motor function. "HEAT2 - NTC2"
7
Motor CW + Heater 1 + Heater 2 + Heater 3
Motor CW + Heater
Check Motor and Heater function. NTC1"
display.
8
Motor Clockwise (CW)
"MOTOR CW"
9
Error code history display
Check last 5 error codes displayed (See
Table above for error code definitions)
10
Software version
Software version...
Product Specifications Sheet (English) - Page 1
..., Touch Up, Timed Dry
Options Temperature Selections Electronic Auto Dry System Manual Timed Dry Selections End-of the industry's longest dryer vent runs.
27" ELECTRIC FRONT LOAD DRYERS
Capacity IEC NSF® Certified
8.0 Cu.
Fastest dry time.1
Largest Capacity Dryer2 Dry the most in under-counter installation require custom-built countertop and/or cabinetry...
Product Specifications Sheet (English) - Page 2
...° elbow. Refer to change specifications or discontinue models without optional 15" drawer pedestal, or stacked above matching Electrolux Washer, which requires stacking kit included with dryer. (For installation details, refer to 53".
Electric Front Load Dryers
EIED55H MB, EIED55H IW
Front
27"
31 1/2"*
Left
50 5/8"*
Reversible Door Swing
Rear
38" (53" with pedestal...
Installation Instructions (All Languages) - Page 2
...dryer according to the manufacturer's instructions and local codes.
• The electrical service to the dryer must conform with local codes and ordinances and the latest edition of the National Electrical Code, ANSI/NFPA 70, or in Canada, the Canadian electrical code...-18 Reversing Door 19-23 Options 24
©2010 Electrolux Major Appliances
All rights reserved. Do not stack washer on the ...
Installation Instructions (All Languages) - Page 3
For toll-free telephone support in home appliances. check with soapy water, NEVER check with flame
240v Electric Supply (Electric Dryer)
Approved NEMA 10-30R or 14-30R service cord with all connections - and Canada: 1-877-4ELECTROLUX (1-877-435-3287). Thank you for choosing Electrolux, the new premium brand in the U.S.
These Installation Instructions are...
Installation Instructions (All Languages) - Page 4
... unless it was manufactured for sale in Canada. The dryer is not recommended. See "Grounding requirements" in Electrical Installation section. time delay fuses or circuit breakers. IMPORTANT
This dryer is prohibited for: (1) new branch circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes do not permit grounding through the neutral link is...
Installation Instructions (All Languages) - Page 5
... the entrance of plastic duct or metal foil duct, replace it with the National Fuel Gas Code, ANSI Z223.1 (latest edition).
2. The dryer MUST be constructed of fire. WARNING
FIRE HAZARD
Do not install a clothes dryer with the Standard for Connectors for the gas supply must comply with flexible plastic or...
Installation Instructions (All Languages) - Page 7
...inches (10.16 cm) in vent restriction.
• The exhaust system should check the exhaust system and vent hood for other flammables are kept or stored...
Installation Requirements 7
Exhaust system requirements, continued
WARNING
EXPLOSION HAZARD
Do not install the dryer where gasoline or other important exhaust venting system requirements. 5. Read the measurement on pedestal...
Installation Instructions (All Languages) - Page 10
... the pre-installation requirements in doubt as to be properly grounded. Grounding requirements - Check with a copper wired receptacle. If it will reduce the risk of electrical shock by any movement of the cord, resulting in a risk of the dryer and can be plugged into an appropriate, copper wired receptacle that matches you are...
Installation Instructions (All Languages) - Page 11
...
ELECTRICAL SHOCK HAZARD
Improper connection of least resistance for your dryer is equipped with a power supply cord having an equipment-grounding conductor and a grounding plug, the plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
Installation Instructions 11
Grounding requirements - Check...
Installation Instructions (All Languages) - Page 14
...Flare Valve Union
GAS FLOW
Flare Union
Closed Nipple
Open
Flexible Connector
Inlet Pipe on the back of Dryer
All connections must be installed by brushing on all pipe connections. to flow through the ...a 1/2 inch to 3/8 inch (1.27 cm to move through the pipe. Check for gas to 0.96 cm) reducer for gas leaks with a manometer. An L.P.
gas service without converting the ...
Similar Questions
Frigerdaire Dryer
model fer641fs0 wiring diagram. Where does green and double red wire g
model fer641fs0 wiring diagram. Where does green and double red wire g
(Posted by fredporche7 8 years ago)
How To Fix Electrolux Dryer Code E64
(Posted by Bjchaurt 9 years ago)
How To Fix E64 Error Dryer
(Posted by nyihran 9 years ago)
How To Change Heating Element In Dryer Eied55hiw
(Posted by coniDS 10 years ago)
How To Remove The Front Face Of A Electrolux Dryer Eied55hiw
(Posted by Azro 10 years ago)