Get support for Casio FX9750GII - 0CALCULATOR GRAPHIC

Casio FX9750GII Support Question

Casio FX9750GII Support Question

Find answers below for this question about Casio FX9750GII - 0CALCULATOR GRAPHIC.
Need a Casio FX9750GII manual? We have 1 online manual for this item!
Question posted by em21Raz on September 26th, 2013

How To Do Standard Deviation On Fx-9750gii

The person who posted this question about this Casio product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Casio FX9750GII Manual Pages

User Guide - Page 10

...change , and to the variables in a notebook-like interface. Icon Mode Name RUN (fx-7400Gɉ only) RUN • MAT*1 (Run • Matrix) Description Use...You can also perform statistical calculations and graph statistical data using the functions. Use this mode to perform single-variable (standard deviation) and paired-variable (regression) statistical calculations, to perform tests, to...
User Guide - Page 29

... {menu for paired-variable statistical estimated value, distribution, standard deviation, variance, and test functions} (all models except fx-7400Gɉ) • {CONV} ... {metric conversion menu} • {HYP} ... {hyperbolic calculation menu} • {PROB} ... {probability/distribution calculation menu} • {NUM} ... {numeric calculation menu} • {ANGL} ... {menu for angle/coordinate...
User Guide - Page 30

...set as the default number system. • Depending on the fx-7400Gɉ. histogram {start division}/{pitch} • {PTS}...number of data}/{mean}/{sum}/{sum of squares}/{population standard deviation}/{sample standard deviation}/{minimum value}/{maximum value} • {Y} ... {...calculator model, some menu items may not be calculated automatically. S FACT - The dot value is normally calculated...
User Guide - Page 31

...}/{size of sample 1}/{size of sample 2}/{mean of sample 1}/{mean of sample 2}/{standard deviation of sample 1}/{standard deviation of sample 2}/{standard deviation of sample p} • {RESLT}* ... {statistical calculation output values} • {TEST} ... {test calculation results} • {p}/{z}/{t}/{Chi}/{F}/{ pˆ }/{ pˆ 1}/{ pˆ 2}/{df}/{se}/{r}/{r 2}/{pa}/{Fa}/{Adf}/{SSa...
User Guide - Page 50

... to extract the {integer}/{fraction} part. • {Rnd} ... {rounds off the value used for internal calculations to specified digits (0 to 9) (see page 2-2).} • {GCD} ... {greatest common divisor for two values...ƫ and standard deviation Ʊ}/{random number generation in the answer memory), or to sexagesimal value} 2-12 S Hyperbolic Calculations (HYP) • {sinh}/{cosh}/{tanh...
User Guide - Page 54

...10 and displays the result on the ListAns screen.) Operation *(E)(PROB)*(RAND)(Int) 1 5U *(E)(PROB)*(RAND)(Int) 1 10 5U * fx-7400GII: (PROB) S Random Number Generation in Accordance with normal distribution based on a specified mean ƫ and standard deviation Ʊ values. Specifying a value for n returns a generated random number as -is the end value. Omitting a value...
User Guide - Page 55

...PROB)*(RAND)(Norm) 8 68 5U * fx-7400GII: (PROB) S Random Number Generation in Accordance with Binomial Distribution (RanBin#) This function generates random integers in accordance with a mean body length of 68cm and standard deviation of 8.) *(E)(PROB)*(RAND)(Norm) ...the number of heads that can be calculated and displayed within a range of random values in the Setup screen. 2-17
User Guide - Page 146

...) The display screen appears as shown above before the graph is drawn. I Displaying the Calculation Results of a Drawn Single-Variable Graph Single-variable statistics can be expressed as shown to the...and Width values. x mean 3x sum 3x2 sum of squares Sx population standard deviation sx sample standard deviation n number of data items minX minimum Q1 first quartile Med median Q3 third...
User Guide - Page 154

... view the items that are lower are displayed, the paired-variable calculation results appear as both graphs and parameter values. Any data already existing in xList 3x ......... When these graphs are negative. maximum of data stored in yList 3y2 ........ sample standard deviation of data stored in xList 3x2 ........ minimum of data stored in...
User Guide - Page 160

...variate t for the data {1, 2, 3}, when the population standard deviation is S = 1.5 and the population mean is ƫ = 2. 6-20 CHE (P() @ EBCU (Percentage of total) Result: 0.30995 (31.0 percentile) I Calculations Using the Distribution Function Important! • The following operations cannot be performed on the fx-7400GII) to draw a rectangular coordinate graph. 3. 4. CHE...
User Guide - Page 161

...fx-7400GII: (STAT)(Var) 6-21 Syntax StdDev(List n [,List m]) Variance(List n [,List m]) List n........Sample data List m.......Frequency data Example To store the x-data below in List 1, the frequency values in the RUN • MAT (or RUN) mode. I Determining Standard Deviation...to determine standard deviation and variance for specified list data. You can perform calculations using ...
User Guide - Page 162

... 6-22 Z testing is known from previous tests. Tests Important! • Test calculations cannot be performed on the fx-7400GII. The Z Test provides a variety of a country) is used for market ...8226; MAT mode or PRGM mode to perform calculations that need to test whether or not a sample accurately represents the population when the standard deviation of samples n = 2 * "ƫ ...
User Guide - Page 163

...) to test the null hypothesis. The t Test tests the hypothesis when the population standard deviation is normally applied to display the test menu, which contains the following pages explain various statistical calculation methods based on independent samples when both population standard deviations are multiple samples. The C2 two-way test creates a cross-tabulation table that...
User Guide - Page 164

...at the bottom of the display, and displays the pointer at the bottom of the function keys shown below to perform the calculation or draw the graph. • (CALC) ... Use B and C to the normal distribution. The 1-Sample Z ... graph. • (Z) ... S 1-Sample Z Test This test is used when the population standard deviation is applied to move the highlighting to test the hypothesis.
User Guide - Page 165

...) (Z) (2-S) The following key operations from list data specification. Calculation Result Output Example M1xM2 direction of successes. S 2-Sample Z Test This test is applied to the normal distribution. S 1-Prop Z Test This test is applied to the normal distribution. The 2-Sample Z Test is used when the standard deviations for an unknown proportion of test sx1 Displayed...
User Guide - Page 175

...standard deviation is known. 2-Sample Z Interval calculates the confidence interval for the difference between two population means when the population standard deviations of two samples are known. 1-Prop Z Interval calculates... the population value. 6. A narrow confidence interval, on the fx-7400GII. Performs the calculation. • There is no graphing for example, the population ...
User Guide - Page 178

... list. (INTR) (t) (2-S) 7. Certain trends can calculate normal probability when estimating what percent of the products will reach this value. Normal distribution is applied to t distribution. Conversely, a success rate target (80% for the difference between two population means when both population standard deviations are also used to calculate the yield rate when manufacturing...
User Guide - Page 237

..." command following the graph condition specification line. Omitting these items performs the calculation using Ʊ = 1 and ƫ = 0.  p = ... Distribution Graphs in a Program (Not available on the fx-7400GII) Special commands are used to draw distribution graphs in...  DrawDistNorm , [,S, ƫ] Population mean*1 Population standard deviation*1 Data upper limit Data lower limit   *1 ...
User Guide - Page 314

... on both units is equipped as a standard accessory. 1. Cable • Models that is off. 2. Connecting the Calculator to a Personal Computer You can transfer data between the calculator and a computer by using the Program-Link Software (FA-124) and a special cable*1 to establish a connection between two CASIO Power Graphic calculators connected using the cable that are...
User Guide - Page 315

.... (Connected with another fx-9860GII SD, fx-9860GII, fx-9860G AU PLUS, fx-9750GII, fx-7400GII, fx-9860G Slim (OS 2.00/1.11), fx-9860G SD (OS 2.00/1.05), fx-9860G (OS 2.00/1.05) or fx-9860G AU (OS 2.00/1.05) calculator) • Parity (PARITY): NONE • USB port* • Communication speed is in accordance with USB standards. * The fx-7400GII is not equipped...

Similar Questions

Standard Deviation Xon-1
Please advise I have a casio fx-991ES plus and need to calculate Standard deviation xon-1 is this po...
(Posted by Anonymous-108196 11 years ago)
How Do I Calculate The Mean And Standard Deviation Using Class Midpoints?
How do I calculate the mean and standard deviation estimates using the class mid points? I went to ...
(Posted by nanokk1112 12 years ago)
Ask a New Question
Use the box below to post a new question about this Casio product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Casio Manuals

Find free Casio FX9750GII - 0CALCULATOR GRAPHIC manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Casio Reviews

View thousands of Casio user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Casio customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Casio customer service rankings, employee comments and much more from our sister site.