Dimension Guide
Page 1
... installation All dimensions show recommended and minimum spacing allowed. W10775221A 12/2015 Companion appliance spacing should be considered on all sides of the dryer to reduce noise transfer. Additional spacing should be considered for ease of installation and servicing. 18" min. (457 mm) 3" ...) 3/4"* (18 mm) 143/8" (365 mm) 253/4" (654 mm) 61/8"* (156 mm) NOTE: Most installations require a minimum of 5" (127 mm) clearance behind dryer for exhaust vent with a door, minimum ventilation openings in .2 min. (155 cm2) 3" (76 mm) 1" (25 mm) 1" (25 mm) Additional spacing should also...
... installation All dimensions show recommended and minimum spacing allowed. W10775221A 12/2015 Companion appliance spacing should be considered on all sides of the dryer to reduce noise transfer. Additional spacing should be considered for ease of installation and servicing. 18" min. (457 mm) 3" ...) 3/4"* (18 mm) 143/8" (365 mm) 253/4" (654 mm) 61/8"* (156 mm) NOTE: Most installations require a minimum of 5" (127 mm) clearance behind dryer for exhaust vent with a door, minimum ventilation openings in .2 min. (155 cm2) 3" (76 mm) 1" (25 mm) 1" (25 mm) Additional spacing should also...
Dimension Guide
Page 2
... and turns. ■■ When using new inlet hoses. To determine maximum exhaust length, add one 90º turn inside the dryer. NOTE: Do not use fewest number of L.P. Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to avoid kinking. ■■ Use as few...
... and turns. ■■ When using new inlet hoses. To determine maximum exhaust length, add one 90º turn inside the dryer. NOTE: Do not use fewest number of L.P. Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to avoid kinking. ■■ Use as few...
Installation Guide
Page 4
...;" and 5/16" nut driver (recommended) Level Pipe-joint compound resistant to 1" (25 mm) or hex-head socket wrench Rubber washer Parts package is located in dryer drum. Tools needed for all installations: Tools needed : (Not supplied with a pedestal or a stack kit. Check that all models): Tape measure Pliers Utility knife ...compound (new vent installations) Adjustable wrench that opens to LP gas Parts supplied (all parts are included. NOTE: Do not use leveling legs supplied with dryer if installing with dryer) ■■Vent clamps ■■Vent elbows and vent work 4
...;" and 5/16" nut driver (recommended) Level Pipe-joint compound resistant to 1" (25 mm) or hex-head socket wrench Rubber washer Parts package is located in dryer drum. Tools needed for all installations: Tools needed : (Not supplied with a pedestal or a stack kit. Check that all models): Tape measure Pliers Utility knife ...compound (new vent installations) Adjustable wrench that opens to LP gas Parts supplied (all parts are included. NOTE: Do not use leveling legs supplied with dryer if installing with dryer) ■■Vent clamps ■■Vent elbows and vent work 4
Installation Guide
Page 5
...the water supply for exhaust vent with elbow. IMPORTANT: Do not operate, install, or store dryer where it will be exposed to bottom of dryer. ■■The dryer must support dryer weight of 200 lbs. (90.7 kg). If not level, clothes may not tumble properly and... Care Guide for information about accessories available for proper exhaust installation. measurement NOTE: Most installations require a minimum of 5" (127 mm) clearance behind dryer for your installation. If using power supply cord, a grounded electrical outlet located within 4 ft. (1.2 m) of the water fill valves, and...
...the water supply for exhaust vent with elbow. IMPORTANT: Do not operate, install, or store dryer where it will be exposed to bottom of dryer. ■■The dryer must support dryer weight of 200 lbs. (90.7 kg). If not level, clothes may not tumble properly and... Care Guide for information about accessories available for proper exhaust installation. measurement NOTE: Most installations require a minimum of 5" (127 mm) clearance behind dryer for your installation. If using power supply cord, a grounded electrical outlet located within 4 ft. (1.2 m) of the water fill valves, and...
Installation Guide
Page 6
... transfer. latest edition and all sides of installation and servicing; The cord is recommended. Additional installation requirements: This dryer is equipped with equivalent ventilation openings are required. Mobile home installations require: ■■Metal exhaust system hardware, available... spacing should be considered. A copy of above codes standard may be considered on all local codes. For mobile home installation of dryer's final location. 4-wire receptacle (14-30R) 6 For further information, see "Assistance or Service" section in garages, closets, ...
... transfer. latest edition and all sides of installation and servicing; The cord is recommended. Additional installation requirements: This dryer is equipped with equivalent ventilation openings are required. Mobile home installations require: ■■Metal exhaust system hardware, available... spacing should be considered. A copy of above codes standard may be considered on all local codes. For mobile home installation of dryer's final location. 4-wire receptacle (14-30R) 6 For further information, see "Assistance or Service" section in garages, closets, ...
Installation Guide
Page 7
... your dealer or call the phone numbers referenced in your home. GROUNDING INSTRUCTIONS I For a grounded, cord-connected dryer: This dryer must be grounded. WARNING: Improper connection of electric shock. In the event of malfunction or breakdown, grounding will ...an equipmentgrounding conductor and a grounding plug. WARNING: Improper connection of electric shock. Check with a different gas without consulting your dryer. grounding conductor can result in the door well of electric shock by a qualified technician. Check with a cord having an equipmentgrounding...
... your dealer or call the phone numbers referenced in your home. GROUNDING INSTRUCTIONS I For a grounded, cord-connected dryer: This dryer must be grounded. WARNING: Improper connection of electric shock. In the event of malfunction or breakdown, grounding will ...an equipmentgrounding conductor and a grounding plug. WARNING: Improper connection of electric shock. Check with a different gas without consulting your dryer. grounding conductor can result in the door well of electric shock by a qualified technician. Check with a cord having an equipmentgrounding...
Installation Guide
Page 8
... codes permit, use a new flexible stainless steel gas connector (Design Certified by the American Gas Association or CSA International) to connect your dryer has been converted to use LP gas, 3⁄8" LP compatible copper tubing can be used . Option 2 (Alternate Method) Approved aluminum ...with the B149.1, Natural Gas and Propane Installation Code. Do not use larger tubing and a different size adapter fitting. ■■If your dryer to flare adapter fitting C. 1⁄8" NPT minimum plugged tapping D. ½" NPT gas supply line E. For a garage installation, the gas ...
... codes permit, use a new flexible stainless steel gas connector (Design Certified by the American Gas Association or CSA International) to connect your dryer has been converted to use LP gas, 3⁄8" LP compatible copper tubing can be used . Option 2 (Alternate Method) Approved aluminum ...with the B149.1, Natural Gas and Propane Installation Code. Do not use larger tubing and a different size adapter fitting. ■■If your dryer to flare adapter fitting C. 1⁄8" NPT minimum plugged tapping D. ½" NPT gas supply line E. For a garage installation, the gas ...
Installation Guide
Page 9
... diamond marking is no kinks. Open shut-off valve in leveling legs B A A. Firmly grasp dryer body (not console panel) and gently lay dryer down on an approved noncorrosive leak-detection solution. If flexible metal tubing is close to existing gas ... elbow D. 3 ⁄8" pipe-to-flare adapter fitting A combination of all connections by hand - Non-flared male fitting Remove red cap from dryer carton; A recommended connection is parallel to supply line type, size, and location. 3. Plan pipe fitting connection (option 1) D C Ddiiaammoonndd mmaarrkkiinngg...
... diamond marking is no kinks. Open shut-off valve in leveling legs B A A. Firmly grasp dryer body (not console panel) and gently lay dryer down on an approved noncorrosive leak-detection solution. If flexible metal tubing is close to existing gas ... elbow D. 3 ⁄8" pipe-to-flare adapter fitting A combination of all connections by hand - Non-flared male fitting Remove red cap from dryer carton; A recommended connection is parallel to supply line type, size, and location. 3. Plan pipe fitting connection (option 1) D C Ddiiaammoonndd mmaarrkkiinngg...
Installation Guide
Page 10
...;■ Only a 4" (102 mm) heavy metal exhaust vent and clamps may result in reduced airflow and poor performance. ■■ Do not install in final dryer location. ■■ Remove excess to avoid crushing and kinking. Replace plastic or metal foil vents with lint. NOTE: If using an existing vent system...; Use clamps to seal all governing codes and ordinances. Recommended Styles: Louvered Hood Acceptable Style: Box Hood WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS.
...;■ Only a 4" (102 mm) heavy metal exhaust vent and clamps may result in reduced airflow and poor performance. ■■ Do not install in final dryer location. ■■ Remove excess to avoid crushing and kinking. Replace plastic or metal foil vents with lint. NOTE: If using an existing vent system...; Use clamps to seal all governing codes and ordinances. Recommended Styles: Louvered Hood Acceptable Style: Box Hood WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS.
Installation Guide
Page 11
Plan Vent System Choose your local dealer to have the dryer converted. Dryer B Elbow C. Exhaust hood E. Vent length necessary to determine type of mobile home and must be converted to avoid kinking. ■■Use as few... specified will provide straightest and most direct path outdoors. ■■Plan installation to use fewest number of dryer. ■■Reduce performance, resulting in "Vent System Charts." Optional exhaust installations: This dryer can be securely fastened to a noncombustible portion of vent material and hood combinations acceptable to use . Exhaust ...
Plan Vent System Choose your local dealer to have the dryer converted. Dryer B Elbow C. Exhaust hood E. Vent length necessary to determine type of mobile home and must be converted to avoid kinking. ■■Use as few... specified will provide straightest and most direct path outdoors. ■■Plan installation to use fewest number of dryer. ■■Reduce performance, resulting in "Vent System Charts." Optional exhaust installations: This dryer can be securely fastened to a noncombustible portion of vent material and hood combinations acceptable to use . Exhaust ...
Installation Guide
Page 12
... mm) 2. Run vent to secure vent, because they can catch lint. Do not use of box/louvered hoods will help achieve best drying performance. The dryer must fit over the exhaust hood. The "Vent System Charts" provide venting requirements that extend into interior of vent to... dryer location using the new inlet hoses (not supplied). A gas model would be DALV - Record hose installation or replacement dates on the serial number plate in ...
... mm) 2. Run vent to secure vent, because they can catch lint. Do not use of box/louvered hoods will help achieve best drying performance. The dryer must fit over the exhaust hood. The "Vent System Charts" provide venting requirements that extend into interior of vent to... dryer location using the new inlet hoses (not supplied). A gas model would be DALV - Record hose installation or replacement dates on the serial number plate in ...
Installation Guide
Page 13
...hand until it is seated on connector. 3. Screw on coupling by hand until it is seated on faucet. Damage to male end of dryer back panel. Turn on fill valve connector. NOTE: Do not overtighten. Then attach "Y" connector to the coupling can result. Using pliers... leaks around "Y" connector, faucet, and hoses. 13 Damage to the "Y" connector. 2. Attach short hose and "Y" connector 5. Attach long hose to dryer fill valve and tighten coupling Attach 2 ft (0.6 m) inlet hose to the coupling can result. 6. Damage to cold water faucet. Check for leaks Attach one...
...hand until it is seated on connector. 3. Screw on coupling by hand until it is seated on faucet. Damage to male end of dryer back panel. Turn on fill valve connector. NOTE: Do not overtighten. Then attach "Y" connector to the coupling can result. Using pliers... leaks around "Y" connector, faucet, and hoses. 13 Damage to the "Y" connector. 2. Attach short hose and "Y" connector 5. Attach long hose to dryer fill valve and tighten coupling Attach 2 ft (0.6 m) inlet hose to the coupling can result. 6. Damage to cold water faucet. Check for leaks Attach one...
Installation Guide
Page 14
...again for the moisture sensing system to exhaust hood with a 4" (102 mm) clamp. 2. Dryer vent must be level for levelness. After dryer is in dryer. Adjust leveling legs Not Level If dryer is level, make sure vent is secured to operate correctly. CONNECT VENT 1. If connecting to... exhaust outlet LEVEL DRYER 1. Repeat from under dryer. Not Level LEVEL 2. Move dryer to final location Check levelness of dryer from side to crush or kink vent or flexible gas line. Move dryer to final location, taking care not to side. Connect...
...again for the moisture sensing system to exhaust hood with a 4" (102 mm) clamp. 2. Dryer vent must be level for levelness. After dryer is in dryer. Adjust leveling legs Not Level If dryer is level, make sure vent is secured to operate correctly. CONNECT VENT 1. If connecting to... exhaust outlet LEVEL DRYER 1. Repeat from under dryer. Not Level LEVEL 2. Move dryer to final location Check levelness of dryer from side to crush or kink vent or flexible gas line. Move dryer to final location, taking care not to side. Connect...
Installation Guide
Page 15
... clog different parts of the water system, which will go back through steps to control the buildup of scale through the water system in the dryer. q Check to the need for models with a damp cloth to remove the door. Electric Models q Plug into a grounded outlet. NOTE: You..., LLC. 15 q Check that gas supply is an extra part, go away. q Check for leaks around "Y" connector, faucet, and hoses. If dryer will not start, check the following instructions are registered trademarks of your Use and Care Guide. This odor is common when heating element is not...
... clog different parts of the water system, which will go back through steps to control the buildup of scale through the water system in the dryer. q Check to the need for models with a damp cloth to remove the door. Electric Models q Plug into a grounded outlet. NOTE: You..., LLC. 15 q Check that gas supply is an extra part, go away. q Check for leaks around "Y" connector, faucet, and hoses. If dryer will not start, check the following instructions are registered trademarks of your Use and Care Guide. This odor is common when heating element is not...
Installation Guide
Page 16
2. Remove inner door from trim ring Using a T25® screwdriver, remove the 2 screws securing the door strike to the door frame of dryer door frame as shown. 3. Rotate the strike 180° and attach to the outer door. Lift off the trim ring and set aside. 16... with the inside of the door facing up. Using a Phillips screwdriver, remove the 10 screws securing the inner door to the opposite side of the dryer. A Fig. B Using a Phillips screwdriver, remove the 2 screws from the outer window retainer and rotate the outer window assembly clockwise until the square notches line...
2. Remove inner door from trim ring Using a T25® screwdriver, remove the 2 screws securing the door strike to the door frame of dryer door frame as shown. 3. Rotate the strike 180° and attach to the outer door. Lift off the trim ring and set aside. 16... with the inside of the door facing up. Using a Phillips screwdriver, remove the 10 screws securing the inner door to the opposite side of the dryer. A Fig. B Using a Phillips screwdriver, remove the 2 screws from the outer window retainer and rotate the outer window assembly clockwise until the square notches line...
Installation Guide
Page 18
... a T25® screwdriver, reinstall the latch plate, latch backing plate, and hinge assembly on the dryer. Reinstall the 10 screws securing the inner door to engage the top tab. Using a T25® screwdriver, remove the 4 screws on the opposite sides from ...
... a T25® screwdriver, reinstall the latch plate, latch backing plate, and hinge assembly on the dryer. Reinstall the 10 screws securing the inner door to engage the top tab. Using a T25® screwdriver, remove the 4 screws on the opposite sides from ...
Installation Guide
Page 19
... frame, as shown. Rotate the strike 180° and attach to the opposite side of the door facing up and out to the dryer and lift up . Lift off the inner door and set aside. 4. Remove inner door from outer door IMPORTANT: If the protective film has not yet ...been removed from the dryer, peel the film from dryer 3. Remove hinge and latch Latch Using a T25® screwdriver, remove the 2 screws securing the door strike to the outer door. Place the door...
... frame, as shown. Rotate the strike 180° and attach to the opposite side of the door facing up and out to the dryer and lift up . Lift off the inner door and set aside. 4. Remove inner door from outer door IMPORTANT: If the protective film has not yet ...been removed from the dryer, peel the film from dryer 3. Remove hinge and latch Latch Using a T25® screwdriver, remove the 2 screws securing the door strike to the outer door. Place the door...
Installation Guide
Page 20
R einstall hinge and latch on the dryer. Secure in place with the 5 screws on the hinge into the mounting slot and slide down to the outer door. 20 Reinstall the 10 screws ... which they were removed. 6. 5. Position the door with the inside of door Using a T25® screwdriver, remove the 4 screws on opposite sides 7. Reinstall door on dryer Using a T25® screwdriver, reinstall the latch plate and latch backing plate with the 3 TORX® screws removed earlier and the hinge assembly with the...
R einstall hinge and latch on the dryer. Secure in place with the 5 screws on the hinge into the mounting slot and slide down to the outer door. 20 Reinstall the 10 screws ... which they were removed. 6. 5. Position the door with the inside of door Using a T25® screwdriver, remove the 4 screws on opposite sides 7. Reinstall door on dryer Using a T25® screwdriver, reinstall the latch plate and latch backing plate with the 3 TORX® screws removed earlier and the hinge assembly with the...
Installation Guide
Page 21
... hinge assembly in the holes. 2. Remove inner door from outer door IMPORTANT: If the protective film has not yet been removed from the dryer, peel the film from dryer 3. Move the door strike Position the door with the inside of the door facing up and out to the outer door. Remove door... from the dryer door before proceeding. Place the door on a soft towel or other non-scratch surface. Reinstall the 4 screws in place. 21 Reverse door swing round-shaped ...
... hinge assembly in the holes. 2. Remove inner door from outer door IMPORTANT: If the protective film has not yet been removed from the dryer, peel the film from dryer 3. Move the door strike Position the door with the inside of the door facing up and out to the outer door. Remove door... from the dryer door before proceeding. Place the door on a soft towel or other non-scratch surface. Reinstall the 4 screws in place. 21 Reverse door swing round-shaped ...