Design Guide - Ventilation
Page 7
...Blower CFM remote Inline Integral 600 • VTN630C 4.8 1000 • VTN1030C 5.0 600 • VTR630D 4.3 1000 • VTR1030D 7.8 1300 • VTR1330E 9.2 600 • VTI610D 5.8 1000 • VTI1010D...VTI1010D 7.6 600 • VTI610D 5.8 600 • VTR630D 5.2 1000 • VTR1030D 7.8 1300 • VTR1330E 9.5 600 • VTI610D 5.8 1000 • VTI1010D...5.8 1000 • VTI1010D 7.6 600 • VTN600F 4.6 1200 • VTN1000F 8.8 ...600 • VTI610D 5.8 1000 • VTI1010D 7.6 • 600 • Included 4.9 ...
...Blower CFM remote Inline Integral 600 • VTN630C 4.8 1000 • VTN1030C 5.0 600 • VTR630D 4.3 1000 • VTR1030D 7.8 1300 • VTR1330E 9.2 600 • VTI610D 5.8 1000 • VTI1010D...VTI1010D 7.6 600 • VTI610D 5.8 600 • VTR630D 5.2 1000 • VTR1030D 7.8 1300 • VTR1330E 9.5 600 • VTI610D 5.8 1000 • VTI1010D...5.8 1000 • VTI1010D 7.6 600 • VTN600F 4.6 1200 • VTN1000F 8.8 ...600 • VTI610D 5.8 1000 • VTI1010D 7.6 • 600 • Included 4.9 ...
Design Guide - Ventilation
Page 9
VENTILATION BLOWER OPTIONS INTEGRAL (MOUNTED ON hOOD) vTn600Cv2C - 600 CFM vTn600F - 600 CFM vTn1080F - 1000 CFM vTn1000F - 1200 CFM vTn630C - 600 CFM 83/4" 81/4" 25" vTn1030C - 1000 CFM 81/4" 25" REMOTE (MOUNTED TO ROOF OR EXTERNAL WALL) vTR630D - 600 CFM vTR1030D - 1000 CFM vTR1330E - 1300 CFM INLINE (MOUNTED BETWEEN KITChEN AND EXTERNAL WALL) vTi610D - 600 CFM vTi1010D - 1000 CFM 140
VENTILATION BLOWER OPTIONS INTEGRAL (MOUNTED ON hOOD) vTn600Cv2C - 600 CFM vTn600F - 600 CFM vTn1080F - 1000 CFM vTn1000F - 1200 CFM vTn630C - 600 CFM 83/4" 81/4" 25" vTn1030C - 1000 CFM 81/4" 25" REMOTE (MOUNTED TO ROOF OR EXTERNAL WALL) vTR630D - 600 CFM vTR1030D - 1000 CFM vTR1330E - 1300 CFM INLINE (MOUNTED BETWEEN KITChEN AND EXTERNAL WALL) vTi610D - 600 CFM vTi1010D - 1000 CFM 140
Design Guide - Ventilation
Page 14
... ceiling heights can also be a minimum of 30", unless otherwise noted. The space can vary between the kitchen and the exterior wall. Inline Blowers (VTI series) To minimize noise in this design guide provides key features, product dimensions, cutouts and installation specifications. If you have.... LENgTH AND SIzE OF DUCTWORK Do not use of make-up air systems when using a 10" duct, Thermador recommends not exceeding 150 feet of interior and exterior blower options (Remote, Inline or Integral) are cross currents and when the hood needs to 1,300 CFM. • For those who...
... ceiling heights can also be a minimum of 30", unless otherwise noted. The space can vary between the kitchen and the exterior wall. Inline Blowers (VTI series) To minimize noise in this design guide provides key features, product dimensions, cutouts and installation specifications. If you have.... LENgTH AND SIzE OF DUCTWORK Do not use of make-up air systems when using a 10" duct, Thermador recommends not exceeding 150 feet of interior and exterior blower options (Remote, Inline or Integral) are cross currents and when the hood needs to 1,300 CFM. • For those who...
Design Guide - Ventilation
Page 15
... - Hood includes filters, lights, backdraft damper and transition - Cable-connected to 10 minutes - Choose from Inline, Remote or Integrated Blowers ACCESSORIES PHREmL - Remote Control Panel - VENTILATION 27-INCH DEPTH WALL HOOD (30"/36"/42"/48"/54") models: PH30CS... 36-Inch PH42CS - 42-Inch PH48CS - 48-Inch PH54CS - 54-Inch SPECIFICATIONS Available Hood Widths UL Approved for Damp Environments Blower Duct Size at serving temperature. Powerfully quiet ventilation systems - Brushed stainless steel finish - Welded, polished seams for damp environments ...
... - Hood includes filters, lights, backdraft damper and transition - Cable-connected to 10 minutes - Choose from Inline, Remote or Integrated Blowers ACCESSORIES PHREmL - Remote Control Panel - VENTILATION 27-INCH DEPTH WALL HOOD (30"/36"/42"/48"/54") models: PH30CS... 36-Inch PH42CS - 42-Inch PH48CS - 48-Inch PH54CS - 54-Inch SPECIFICATIONS Available Hood Widths UL Approved for Damp Environments Blower Duct Size at serving temperature. Powerfully quiet ventilation systems - Brushed stainless steel finish - Welded, polished seams for damp environments ...
Design Guide - Ventilation
Page 16
... PH30CS, PH36CS, PH42CS, PH48CS, PH54CS INSTALLATION OPTIONS Thermador Wall Hoods may be installed above a Thermador Professional Cooktop or Range, consult the appliance's installation manual. To obtain the necessary installation height above a Thermador Cooktop or Range to create a convenient cooking center.... WC10 Wall Cap INLINE (mounted between the hood and ceiling. BLOWER OPTIONS REmOTE VTR630D - 600 CFM Use RFPLT600 in roof-mount applications VTR1030D - 1000 CFM VTR1330E - 1300 CFM Use RFPLT1000 in roof-mount applications INLINE VTI610D - 600 CFM VTI1010D - 1000 CFM INTEgRATED...
... PH30CS, PH36CS, PH42CS, PH48CS, PH54CS INSTALLATION OPTIONS Thermador Wall Hoods may be installed above a Thermador Professional Cooktop or Range, consult the appliance's installation manual. To obtain the necessary installation height above a Thermador Cooktop or Range to create a convenient cooking center.... WC10 Wall Cap INLINE (mounted between the hood and ceiling. BLOWER OPTIONS REmOTE VTR630D - 600 CFM Use RFPLT600 in roof-mount applications VTR1030D - 1000 CFM VTR1330E - 1300 CFM Use RFPLT1000 in roof-mount applications INLINE VTI610D - 600 CFM VTI1010D - 1000 CFM INTEgRATED...
Design Guide - Ventilation
Page 19
... - 36-Inch HMWN48FS - 48-Inch SPECIFICATIONS Available Hood Widths 30", 36", 48" Blower Sold separately - Brushed stainless steel finish - Choose from Inline, Remote or Integrated Blowers - Welded, polished seams for up to duct installations - Stainless steel finish -...Inch 6-Inch High DC30US DC36US DC48US 12-Inch High DCT30US DCT36US DCT48US RECIRC__FS - Blowers sold separately - Powerfully quiet ventilation systems - Classic chiseled design matches Thermador's Masterpiece® Series family of smoke and odor DESIgN - Premium electronic touch...
... - 36-Inch HMWN48FS - 48-Inch SPECIFICATIONS Available Hood Widths 30", 36", 48" Blower Sold separately - Brushed stainless steel finish - Choose from Inline, Remote or Integrated Blowers - Welded, polished seams for up to duct installations - Stainless steel finish -...Inch 6-Inch High DC30US DC36US DC48US 12-Inch High DCT30US DCT36US DCT48US RECIRC__FS - Blowers sold separately - Powerfully quiet ventilation systems - Classic chiseled design matches Thermador's Masterpiece® Series family of smoke and odor DESIgN - Premium electronic touch...
Design Guide - Ventilation
Page 20
..." hood) INLINE VTI610D - 600 CFM VTI1010D - 1000 CFM INTEgRATED VTN600F - 600 CFM VTN1000F - 1200 CFM Not for use with Remote Blowers VTR630D, VTR1030D and VTR1330E Combinations Roof plate RFPLT600 RFPLT1000 Remote Blower VTR630D VTR1030D, VTR1330E Overall Dimensions model No. WALL HOODS VENTILATION WALL HOOD (30"/36"/48") models: HmWN30FS, HmWN36FS, HmWN48FS INSTALLATION OPTIONS Thermador Wall...
..." hood) INLINE VTI610D - 600 CFM VTI1010D - 1000 CFM INTEgRATED VTN600F - 600 CFM VTN1000F - 1200 CFM Not for use with Remote Blowers VTR630D, VTR1030D and VTR1330E Combinations Roof plate RFPLT600 RFPLT1000 Remote Blower VTR630D VTR1030D, VTR1330E Overall Dimensions model No. WALL HOODS VENTILATION WALL HOOD (30"/36"/48") models: HmWN30FS, HmWN36FS, HmWN48FS INSTALLATION OPTIONS Thermador Wall...
Design Guide - Ventilation
Page 26
...option. Proper performance is very important. Inline Blowers (VTI series) To minimize noise in the kitchen, these blowers can sometimes vary by boiling large pots of your hood within the recommended range (typically 30" to 36" above a Thermador non-professional gas, electric, or ...air movement. VENTILATION - Before installing a Thermador Chimney Wall Hood, be filled using a more appealing to address this issue. Thermador Chimney Wall Hoods may remain after proper installation of interior and exterior blower options (Remote, Inline or Integral) are best. The space can...
...option. Proper performance is very important. Inline Blowers (VTI series) To minimize noise in the kitchen, these blowers can sometimes vary by boiling large pots of your hood within the recommended range (typically 30" to 36" above a Thermador non-professional gas, electric, or ...air movement. VENTILATION - Before installing a Thermador Chimney Wall Hood, be filled using a more appealing to address this issue. Thermador Chimney Wall Hoods may remain after proper installation of interior and exterior blower options (Remote, Inline or Integral) are best. The space can...
Design Guide - Ventilation
Page 27
... grease - Brushed stainless steel finish - Chimney Extension - Halogen lighting spotlights your best recipes - Telescopic chimney - Blowers sold separately - Welded, polished seams for those hours after a late meal - Built-in Clean Filter Reminder light -...Classic chiseled design matches Thermador's Masterpiece® Series family of standard chimney extension 158 Premium electronic touch controls CONVENIENCE - Choose from Inline, Remote or Integrated Blowers SPECIFICATIONS Available Hood Widths 36", 42" Blower Sold Separately- See Blower Options Table Duct Size...
... grease - Brushed stainless steel finish - Chimney Extension - Halogen lighting spotlights your best recipes - Telescopic chimney - Blowers sold separately - Welded, polished seams for those hours after a late meal - Built-in Clean Filter Reminder light -...Classic chiseled design matches Thermador's Masterpiece® Series family of standard chimney extension 158 Premium electronic touch controls CONVENIENCE - Choose from Inline, Remote or Integrated Blowers SPECIFICATIONS Available Hood Widths 36", 42" Blower Sold Separately- See Blower Options Table Duct Size...
Design Guide - Ventilation
Page 28
...-mount applications VTR1030D - 1000 CFM Use RFPLT1000 in VTR1330E - 1300 CFM roof-mount applications INLINE VTI610D - 600 CFM VTI1010D - 1000 CFM INTEgRATED VTN1080F - 1000 CFM See page 145 for additional specifications. A blower must be installed above a Thermador non-professional gas, electric, or induction cooktop to be purchased separately. To obtain the necessary...
...-mount applications VTR1030D - 1000 CFM Use RFPLT1000 in VTR1330E - 1300 CFM roof-mount applications INLINE VTI610D - 600 CFM VTI1010D - 1000 CFM INTEgRATED VTN1080F - 1000 CFM See page 145 for additional specifications. A blower must be installed above a Thermador non-professional gas, electric, or induction cooktop to be purchased separately. To obtain the necessary...
Design Guide - Ventilation
Page 38
... a good alternative. • High heat cooking or aromatic foods may be sure to verify the dimensions and electrical connections. Before selecting a Thermador Hood, check the available installation space and any extra space that will vary based on each hood and cooktop/ range model for proper hood ... installation. The specified CFM varies from the cooking surface to reduce noise in the same room, can also be purchased separately. Inline Blowers (VTI Series) To minimize noise in determining CFM needs for every 100 BTU. CHOOSINg THE RIgHT CFM The power of a hood and ...
... a good alternative. • High heat cooking or aromatic foods may be sure to verify the dimensions and electrical connections. Before selecting a Thermador Hood, check the available installation space and any extra space that will vary based on each hood and cooktop/ range model for proper hood ... installation. The specified CFM varies from the cooking surface to reduce noise in the same room, can also be purchased separately. Inline Blowers (VTI Series) To minimize noise in determining CFM needs for every 100 BTU. CHOOSINg THE RIgHT CFM The power of a hood and ...
Design Guide - Ventilation
Page 39
...at capturing grease - Dishwasher safe aluminum mesh filters - After 40 hours of operation, the Clean Filter button illuminates - See Blower Options Table Duct Size at Discharge Ducting Direction Ceiling Heights Dishwasher Safe Filters Halogen Lighting 8" Round Vertical 8 1/4 ft. Auto start High... PERFORMANCE - 3 fan speeds plus 10 minute high-power operation mode - Welded, polished seams for up to 10 ft. Choose from Inline or Remote Blowers - VENTILATION ISLAND HOOD (42"/48"/54") Models: HNI42YS, HNI48YS, HNI54YS PROFESSIONAL HNI42YS - 42-Inch HNI48YS - 48-Inch HNI54YS -...
...at capturing grease - Dishwasher safe aluminum mesh filters - After 40 hours of operation, the Clean Filter button illuminates - See Blower Options Table Duct Size at Discharge Ducting Direction Ceiling Heights Dishwasher Safe Filters Halogen Lighting 8" Round Vertical 8 1/4 ft. Auto start High... PERFORMANCE - 3 fan speeds plus 10 minute high-power operation mode - Welded, polished seams for up to 10 ft. Choose from Inline or Remote Blowers - VENTILATION ISLAND HOOD (42"/48"/54") Models: HNI42YS, HNI48YS, HNI54YS PROFESSIONAL HNI42YS - 42-Inch HNI48YS - 48-Inch HNI54YS -...
Design Guide - Ventilation
Page 40
..."/54") Models: HNI42YS, HNI48YS, HNI54YS BLOWER OPTIONS REMOTE VTR1030D - 1000 CFM Use RFPLT1000 in roof-mount applications VTR1330E - 1300 CFM Use RFPLT1000 in roof-mount applications INLINE VTI1010D - 1000 CFM See page 145 for vertical discharge. RFPLT1000 A 9 3/8" Overall Dimensions B C Duct Size 12" 11 1/8" 10" 1.800.735.4328 | THERMADOR.COM 171 ISLAND HOODS INSTALLATION OPTIONS...
..."/54") Models: HNI42YS, HNI48YS, HNI54YS BLOWER OPTIONS REMOTE VTR1030D - 1000 CFM Use RFPLT1000 in roof-mount applications VTR1330E - 1300 CFM Use RFPLT1000 in roof-mount applications INLINE VTI1010D - 1000 CFM See page 145 for vertical discharge. RFPLT1000 A 9 3/8" Overall Dimensions B C Duct Size 12" 11 1/8" 10" 1.800.735.4328 | THERMADOR.COM 171 ISLAND HOODS INSTALLATION OPTIONS...
Design Guide - Ventilation
Page 46
...who are all professional-style cooktops and ranges. HOOD WIDTH The hood width should be mounted higher. Blower selection will add more powerful blower. Inline Blowers (VTI series) To minimize noise in a peninsula or island, a larger capacity hood can provide ...Inline or Integral) are best. CHOOSING THE CORRECT BLOWER A variety of cooktop width. These minimum distances range from locale to handle moisture generated by manufacturer. For Masterpiece® Electric and Induction Cooktops, and Gas Cooktops under 60,000 BTU, choose a blower with the product for Thermador...
...who are all professional-style cooktops and ranges. HOOD WIDTH The hood width should be mounted higher. Blower selection will add more powerful blower. Inline Blowers (VTI series) To minimize noise in a peninsula or island, a larger capacity hood can provide ...Inline or Integral) are best. CHOOSING THE CORRECT BLOWER A variety of cooktop width. These minimum distances range from locale to handle moisture generated by manufacturer. For Masterpiece® Electric and Induction Cooktops, and Gas Cooktops under 60,000 BTU, choose a blower with the product for Thermador...
Design Guide - Ventilation
Page 47
...insert - Powerfully quiet ventilation systems - Stainless steel button controls CONVENIENCE - Choose from Inline, Remote or Integrated Blowers SPECIFICATIONS Available Hood Widths 30", 36", 48" Blower Sold Separately- Cable-connected to 10 minutes - Dishwasher safe for efficient...styles VCI2REM VCI2REMFS 14 1/2" 4 1/2" ACCESSORIES BAFFLT - Delayed shutoff tackles lingering odors for wall or island applications - See Blower Options Table Duct Size at capturing grease - Stainless steel finish - For use with VCI2__DS - For use with...
...insert - Powerfully quiet ventilation systems - Stainless steel button controls CONVENIENCE - Choose from Inline, Remote or Integrated Blowers SPECIFICATIONS Available Hood Widths 30", 36", 48" Blower Sold Separately- Cable-connected to 10 minutes - Dishwasher safe for efficient...styles VCI2REM VCI2REMFS 14 1/2" 4 1/2" ACCESSORIES BAFFLT - Delayed shutoff tackles lingering odors for wall or island applications - See Blower Options Table Duct Size at capturing grease - Stainless steel finish - For use with VCI2__DS - For use with...
Design Guide - Ventilation
Page 48
... in roof-mount applications VTR1330E - 1300 CFM Use RFPLT1000 in roof-mount applications INLINE VTI610D - 600 CFM VTI1010D - 1000 CFM INTEGRATED VTI610D - 600 CFM Inline blower can vary from the cooking surface to the design and installation of the custom ... Thermador Custom Hood Inserts within custom hood applications create a seamless design with Remote Blowers VTR630D, VTR1030D and VTR1330E Combinations Roofplate RFPLT600 RFPLT1000 Remote Blower VTR630D VTR1030D, VTR1330E INLINE (Mounted between kitchen and external wall) INTEGRAL (Mounted on hood) VTI610D 600 CFM VTI1010D ...
... in roof-mount applications VTR1330E - 1300 CFM Use RFPLT1000 in roof-mount applications INLINE VTI610D - 600 CFM VTI1010D - 1000 CFM INTEGRATED VTI610D - 600 CFM Inline blower can vary from the cooking surface to the design and installation of the custom ... Thermador Custom Hood Inserts within custom hood applications create a seamless design with Remote Blowers VTR630D, VTR1030D and VTR1330E Combinations Roofplate RFPLT600 RFPLT1000 Remote Blower VTR630D VTR1030D, VTR1330E INLINE (Mounted between kitchen and external wall) INTEGRAL (Mounted on hood) VTI610D 600 CFM VTI1010D ...
Design Guide - Ventilation
Page 53
... selected does not have easy access to your duct line (in a wall or island behind a Thermador non-professional gas, electric or induction cooktop to select your kitchen. Inline Blowers (VTI series) To minimize noise in the kitchen. For long duct runs with a splatter shield ... before installing. 184 Thermador Downdraft Hoods may be the same width as possible. Be sure to verify the cutout dimensions and electrical connections. Blower selection will vary based on the roof or exterior wall of interior and exterior blower options (Remote, Inline or Integral) are mounted...
... selected does not have easy access to your duct line (in a wall or island behind a Thermador non-professional gas, electric or induction cooktop to select your kitchen. Inline Blowers (VTI series) To minimize noise in the kitchen. For long duct runs with a splatter shield ... before installing. 184 Thermador Downdraft Hoods may be the same width as possible. Be sure to verify the cutout dimensions and electrical connections. Blower selection will vary based on the roof or exterior wall of interior and exterior blower options (Remote, Inline or Integral) are mounted...
Design Guide - Ventilation
Page 54
...to handle moisture generated by 3" on hood) VTN600CV2C 600 CFM INLINE (Mounted between kitchen and external wall) VTI610D 600 CFM VTI1010D 1000 CFM REMOTE BLOWER ACCESSORIES RFPLT600, RFPLT1000 - Increasing capture area by boiling large pots...blowers - Use a qualified and trained installer. Local building codes may require the use of make-up air systems when using a 10" duct, Thermador recommends not exceeding 150 feet of the cooktop, measured in BTU, is perhaps the most important factor in roof-mount applications INLINE Requires CV2T6 Transition VTI610D - 600 CFM VTI1010D...
...to handle moisture generated by 3" on hood) VTN600CV2C 600 CFM INLINE (Mounted between kitchen and external wall) VTI610D 600 CFM VTI1010D 1000 CFM REMOTE BLOWER ACCESSORIES RFPLT600, RFPLT1000 - Increasing capture area by boiling large pots...blowers - Use a qualified and trained installer. Local building codes may require the use of make-up air systems when using a 10" duct, Thermador recommends not exceeding 150 feet of the cooktop, measured in BTU, is perhaps the most important factor in roof-mount applications INLINE Requires CV2T6 Transition VTI610D - 600 CFM VTI1010D...
Design Guide - Ventilation
Page 55
... at capturing grease - Easy to integrated blower (VTN600CV2C) under cooktop - Downdraft recirculation possible with UCVM__FS - Blowers sold separately) - For use with Thermador downdraft and integrated blower repLacement cHarcoaL fILterS Sold Separately as a splatter shield - Easily mounts to operate control buttons capacIty - Mounts to capture steam from Inline, Remote or Integrated Blowers acceSSorIeS recIrc36Df - Suitable for wall...
... at capturing grease - Easy to integrated blower (VTN600CV2C) under cooktop - Downdraft recirculation possible with UCVM__FS - Blowers sold separately) - For use with Thermador downdraft and integrated blower repLacement cHarcoaL fILterS Sold Separately as a splatter shield - Easily mounts to operate control buttons capacIty - Mounts to capture steam from Inline, Remote or Integrated Blowers acceSSorIeS recIrc36Df - Suitable for wall...