Use and care GUIDE Professional Series Rangetops Table of contents (English 4 Table de matières (Français 34 Índice de materias (Español 65 Models | Modèles | Modelos: PCG305W PCG366W PCG364WD PCG364WL PCG486WL PCG486WD THERMADOR.COM
Use and care GUIDE Professional Series Rangetops Table of contents (English 4 Table de matières (Français 34 Índice de materias (Español 65 Models | Modèles | Modelos: PCG305W PCG366W PCG364WD PCG364WL PCG486WL PCG486WD THERMADOR.COM
Instructions for Use
Page 17
...; Select the base diameter to the base or in aluminum foil should not be placed directly on the rangetop. • Placement of large stock pots should be contained under size pans sacrifice cooking performance. Aluminum foil can melt during cooking. • DO NOT ... with metal handles are warped, dented, ridged or too lightweight will shorten cooking time and make it unevenly. They may melt or catch fire. • Professional quality pans with one burner, such as a griddle, for stability and even cooking. These metals are pan materials that generates harmful by-products. •...
...; Select the base diameter to the base or in aluminum foil should not be placed directly on the rangetop. • Placement of large stock pots should be contained under size pans sacrifice cooking performance. Aluminum foil can melt during cooking. • DO NOT ... with metal handles are warped, dented, ridged or too lightweight will shorten cooking time and make it unevenly. They may melt or catch fire. • Professional quality pans with one burner, such as a griddle, for stability and even cooking. These metals are pan materials that generates harmful by-products. •...
Instruction manual
Page 2
Use and Care GUIDE Professional Series Rangetops Table of Contents (English 4 Table de Matières (Français 35 Índice de Materias (Español 66 Models/ Modèles/ Modelos: PCG305W PCG366W PCG364WD PCG364WL PCG486WL PCG486WD THERMADOR.COM
Use and Care GUIDE Professional Series Rangetops Table of Contents (English 4 Table de Matières (Français 35 Índice de Materias (Español 66 Models/ Modèles/ Modelos: PCG305W PCG366W PCG364WD PCG364WL PCG486WL PCG486WD THERMADOR.COM
Instruction manual
Page 18
... heavier than the pan and tilt it possible to use lower heat settings. This can damage your pan and the cooking surface. • Professional quality pans with a hot burner grate. They may melt or catch fire. • Never let a pan boil dry. Pan bases that... A properly fitting lid will heat unevenly. should never be used on the rangetop. • Placement of large stock pots should be staggered when used on the rangetop. • Select the base diameter to distort cookware. Professional quality pans are recommended because plastic handles can melt during cooking. • ...
... heavier than the pan and tilt it possible to use lower heat settings. This can damage your pan and the cooking surface. • Professional quality pans with a hot burner grate. They may melt or catch fire. • Never let a pan boil dry. Pan bases that... A properly fitting lid will heat unevenly. should never be used on the rangetop. • Placement of large stock pots should be staggered when used on the rangetop. • Select the base diameter to distort cookware. Professional quality pans are recommended because plastic handles can melt during cooking. • ...
Installation instructions
Page 1
Ventilation Planning GUIDE For PROFESSIONAL and MASTERPIECE Ranges, Rangetops, Cooktops, and Hoods THERMADOR.COM
Ventilation Planning GUIDE For PROFESSIONAL and MASTERPIECE Ranges, Rangetops, Cooktops, and Hoods THERMADOR.COM
Installation instructions
Page 2
...the inlet of a remote blower gives the best delivery. • For Thermador Professional applications with a non-approved Thermador hood, the hood and/or blower must be rated for 1 CFM for every 100 BTU on the Range/Rangetop/Cooktop. • If the range has a 12'' Griddle, add an... BTU on each end. • A 25 foot extension cable (EXTNCB25W) is recommended to use a hood width that a THERMADOR range, rangetop, and cooktop are not recommended. PROFESSIONAL hoods with all hoods referenced. In-Line or Other Available Blower Remote Blower Blowers NOTE - All blower models referenced may not...
...the inlet of a remote blower gives the best delivery. • For Thermador Professional applications with a non-approved Thermador hood, the hood and/or blower must be rated for 1 CFM for every 100 BTU on the Range/Rangetop/Cooktop. • If the range has a 12'' Griddle, add an... BTU on each end. • A 25 foot extension cable (EXTNCB25W) is recommended to use a hood width that a THERMADOR range, rangetop, and cooktop are not recommended. PROFESSIONAL hoods with all hoods referenced. In-Line or Other Available Blower Remote Blower Blowers NOTE - All blower models referenced may not...
Installation instructions
Page 3
... VTR1030W VTR1330W MASTERPIECE hoods with Griddle or Induction HMWB36WS, HMWB361WS NOTE - All combinations below must use minimum 10" diameter duct. 48'' HMWB481WS PROFESSIONAL Range or Rangetop Model with MASTERPIECE hoods with Grill and Griddle HMWB481WS Page. 2 All combinations below must use minimum 8" diameter duct. 30'' HMWB30WS, HMDW30WS,...- All combinations below must use minimum 10" diameter duct. 36'' with Grill HMWB361WS, HMWB481WS 48'' with Grill 48'' with blower included: PROFESSIONAL Range or Rangetop Model Recommended Hood Models NOTE - NOTE -
... VTR1030W VTR1330W MASTERPIECE hoods with Griddle or Induction HMWB36WS, HMWB361WS NOTE - All combinations below must use minimum 10" diameter duct. 48'' HMWB481WS PROFESSIONAL Range or Rangetop Model with MASTERPIECE hoods with Grill and Griddle HMWB481WS Page. 2 All combinations below must use minimum 8" diameter duct. 30'' HMWB30WS, HMDW30WS,...- All combinations below must use minimum 10" diameter duct. 36'' with Grill HMWB361WS, HMWB481WS 48'' with Grill 48'' with blower included: PROFESSIONAL Range or Rangetop Model Recommended Hood Models NOTE - NOTE -
Product Spec Sheet
Page 1
... of Center 12" Electric Grill (W) Power of Back Right Burner (NG) Power of 5 10 / 19 to Combustible Surface 142 lbs 2 Year THERMADOR® EXCLUSIVE Page 1 of Front Right Burner (NG) TECHNICAL DETAILS Circuit Breaker (A) Volts (V) Frequency (Hz) Plug Type / Receptacle Power Cord ... Min. (USA) Yes 8 1/8" x 35 15/16" x 25 13/16" 7 11/16" x 35 1/8" x 22 13/16" 6" Min. PCG366W 36-INCH GAS RANGETOP PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE FEATURES & BENEFITS - Patented Pedestal Star® Burner with QuickClean Base® designed for easy surface cleaning and superior heat spread...
... of Center 12" Electric Grill (W) Power of Back Right Burner (NG) Power of 5 10 / 19 to Combustible Surface 142 lbs 2 Year THERMADOR® EXCLUSIVE Page 1 of Front Right Burner (NG) TECHNICAL DETAILS Circuit Breaker (A) Volts (V) Frequency (Hz) Plug Type / Receptacle Power Cord ... Min. (USA) Yes 8 1/8" x 35 15/16" x 25 13/16" 7 11/16" x 35 1/8" x 22 13/16" 6" Min. PCG366W 36-INCH GAS RANGETOP PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE FEATURES & BENEFITS - Patented Pedestal Star® Burner with QuickClean Base® designed for easy surface cleaning and superior heat spread...
Product Spec Sheet
Page 2
PCG366W 36-INCH GAS RANGETOP PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE ACCESSORIES (OPTIONAL) PAGRIDDLE Griddle Sits on Top of Grates Over 2 Star Burners PA36WLBC 10" Low Backguard 36" RANGETOP SIDE VIEW PA12CHPBLK 12" Cutting Board PAKNOBLUWR Metallic Blue Knob Kit PWOKRINGHC Wok Ring PALPKITHW LP Conversion Kit, Pro Rangetops (4 & 6 Burners) Page 2 of 5 10 / 19
PCG366W 36-INCH GAS RANGETOP PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE ACCESSORIES (OPTIONAL) PAGRIDDLE Griddle Sits on Top of Grates Over 2 Star Burners PA36WLBC 10" Low Backguard 36" RANGETOP SIDE VIEW PA12CHPBLK 12" Cutting Board PAKNOBLUWR Metallic Blue Knob Kit PWOKRINGHC Wok Ring PALPKITHW LP Conversion Kit, Pro Rangetops (4 & 6 Burners) Page 2 of 5 10 / 19
Product Spec Sheet
Page 4
... left rear underside of 5 10 / 19 water column (27.4 mb to 14" max. DO NOT ALTER THIS PLUG. Page 4 of the rangetop. PCG366W 36-INCH GAS RANGETOP PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE 36-INCH RANGETOP GAS LOCATION The gas and electrical supply must be located in an area that is equipped with all-burner gas...
... left rear underside of 5 10 / 19 water column (27.4 mb to 14" max. DO NOT ALTER THIS PLUG. Page 4 of the rangetop. PCG366W 36-INCH GAS RANGETOP PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE 36-INCH RANGETOP GAS LOCATION The gas and electrical supply must be located in an area that is equipped with all-burner gas...
Product Spec Sheet
Page 5
... use in Canada. 1 800 735 4328 | USA THERMADOR.COM | CANADA THERMADOR.CA | ©2019 BSH HOME APPLIANCES CORPORATION. For the most detailed information, refer to installation instructions accompanying product or write to making counter opening. Specifications are certified for your specific ventilation requirements. PCG366W 36-INCH GAS RANGETOP PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE 36-INCH...
... use in Canada. 1 800 735 4328 | USA THERMADOR.COM | CANADA THERMADOR.CA | ©2019 BSH HOME APPLIANCES CORPORATION. For the most detailed information, refer to installation instructions accompanying product or write to making counter opening. Specifications are certified for your specific ventilation requirements. PCG366W 36-INCH GAS RANGETOP PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE 36-INCH...
Installation Instructions
Page 1
Installation INSTRUCTIONS Professional Series Rangetops THERMADOR.COM
Installation INSTRUCTIONS Professional Series Rangetops THERMADOR.COM
Installation Instructions
Page 3
Installation INSTRUCTIONS Professional Series Rangetops Table of contents (English 2 Table de matières (Français 19 Índice de materias (Español 38 Models | Modèles | Modelos: PCG305W PCG366W PCG364WD PCG364WL PCG486WL PCG486WD THERMADOR.COM
Installation INSTRUCTIONS Professional Series Rangetops Table of contents (English 2 Table de matières (Français 19 Índice de materias (Español 38 Models | Modèles | Modelos: PCG305W PCG366W PCG364WD PCG364WL PCG486WL PCG486WD THERMADOR.COM
Installation Instructions
Page 8
... (330 mm). • Wall cabinets within this 5'' (127 mm) side clearance must be strong enough to allow clearance for the rangetop front (see page 10). A Thermador Low Backguard must have a space wide enough to the unit. NOTES: • If a solid side cabinet wall exists on the ...cooking surface and the bottom of an unprotected cabinet. It may be solid combustible or noncombustible material. Installation clearances • To ensure professional results, the cabinet and countertop openings should be the same as the center of the overhead ventilation hood. • Cut the openings...
... (330 mm). • Wall cabinets within this 5'' (127 mm) side clearance must be strong enough to allow clearance for the rangetop front (see page 10). A Thermador Low Backguard must have a space wide enough to the unit. NOTES: • If a solid side cabinet wall exists on the ...cooking surface and the bottom of an unprotected cabinet. It may be solid combustible or noncombustible material. Installation clearances • To ensure professional results, the cabinet and countertop openings should be the same as the center of the overhead ventilation hood. • Cut the openings...
Installation Instructions
Page 14
...the Use and Care Guide. A high altitude kit is installed in its own high pressure regulator in a location accessible from scratches, until the rangetop is required for natural gas above 5,400 feet (1,646 m) elevation above sea level, and for proper grounding. • The gas supply ...with the back of the gas shut-off valve must not exceed 14" water column (34.9 mb). The rangetop must not interfere with local codes or ordinances. Ensure that a Certified Professional make certain the propane gas tank is turned off at test pressures equal to or less than 1/ 2 psig...
...the Use and Care Guide. A high altitude kit is installed in its own high pressure regulator in a location accessible from scratches, until the rangetop is required for natural gas above 5,400 feet (1,646 m) elevation above sea level, and for proper grounding. • The gas supply ...with the back of the gas shut-off valve must not exceed 14" water column (34.9 mb). The rangetop must not interfere with local codes or ordinances. Ensure that a Certified Professional make certain the propane gas tank is turned off at test pressures equal to or less than 1/ 2 psig...