Instructions for Use
Page 6
... the Installation Instructions for Mobile Home Construction and Safety, Title 24, HUD (Part 280)] or with the product. Installation and maintenance must be longer than 36'' (914 mm). Wait at least 5 minutes before servicing this product. To light the burners manually, carefully hold a lighted match to the burner ports and turn...
... the Installation Instructions for Mobile Home Construction and Safety, Title 24, HUD (Part 280)] or with the product. Installation and maintenance must be longer than 36'' (914 mm). Wait at least 5 minutes before servicing this product. To light the burners manually, carefully hold a lighted match to the burner ports and turn...
Instruction manual
Page 6
... the ExtraLow® feature and cannot be lit manually. Wait at least 5 minutes before lighting the burner manually. The appliance must not be longer than 36'' (914 mm). Have the installer show you can use the appliance until the gas has had time to dissipate. For Massachusetts Installations: 1. DO NOT repair...
... the ExtraLow® feature and cannot be lit manually. Wait at least 5 minutes before lighting the burner manually. The appliance must not be longer than 36'' (914 mm). Have the installer show you can use the appliance until the gas has had time to dissipate. For Massachusetts Installations: 1. DO NOT repair...
Installation instructions
Page 2
... ventilation combinations for purchase to connect the hood to the estimated blower capacity. • For Thermador Masterpiece applications with a non-approved Thermador hood, the hood and/or blower must use minimum 8" diameter duct. 30'' 36'' without Grill or Griddle 36'' with Griddle or Induction PH30HWS, HPCN36WS, PH36GWS, PH36HWS, VCIN36GWS VTN1090R HPCN36WS, PH36GWS, PH36HWS, VCIN36GWS...
... ventilation combinations for purchase to connect the hood to the estimated blower capacity. • For Thermador Masterpiece applications with a non-approved Thermador hood, the hood and/or blower must use minimum 8" diameter duct. 30'' 36'' without Grill or Griddle 36'' with Griddle or Induction PH30HWS, HPCN36WS, PH36GWS, PH36HWS, VCIN36GWS VTN1090R HPCN36WS, PH36GWS, PH36HWS, VCIN36GWS...
Installation instructions
Page 3
... must use minimum 8" diameter duct. 30'' HMWB30WS, HMWB36WS 36'' without Grill or Griddle 36'' with Grill and Griddle HMWB481WS Page. 2 All combinations below must use minimum 10" diameter duct. 36'' with Grill HPCN36WS, PH36GWS, PH36HWS, VCIN36GWS, PH42GWS, HPCN48WS...HMCB30WS, HDDB30WS, HMWB36WS, HMDW36WS, HMCB36WS, HDDB36WS, HMIB36WS, HMIB42WS, HMWB361WS 36'' HMWB36WS, HMDW36WS, HMCB36WS, HDDB36WS, HMIB42WS, HMWB361WS NOTE - NOTE - All combinations below must use minimum 10" diameter duct. 36'' with Grill HMWB361WS, HMWB481WS 48'' with Grill 48'' with Griddle ...
... must use minimum 8" diameter duct. 30'' HMWB30WS, HMWB36WS 36'' without Grill or Griddle 36'' with Grill and Griddle HMWB481WS Page. 2 All combinations below must use minimum 10" diameter duct. 36'' with Grill HPCN36WS, PH36GWS, PH36HWS, VCIN36GWS, PH42GWS, HPCN48WS...HMCB30WS, HDDB30WS, HMWB36WS, HMDW36WS, HMCB36WS, HDDB36WS, HMIB36WS, HMIB42WS, HMWB361WS 36'' HMWB36WS, HMDW36WS, HMCB36WS, HDDB36WS, HMIB42WS, HMWB361WS NOTE - NOTE - All combinations below must use minimum 10" diameter duct. 36'' with Grill HMWB361WS, HMWB481WS 48'' with Grill 48'' with Griddle ...
Product Spec Sheet
Page 1
PCG366W 36-INCH GAS RANGETOP PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE FEATURES & BENEFITS - Patented Pedestal Star® Burner with QuickClean Base® designed for easy surface cleaning and ... size pan - Precision simmering capabilities as low as 100°F (375 BTU) with 2 ExtraLow® Simmer burners - LED Downlighting - to Combustible Surface 142 lbs 2 Year THERMADOR® EXCLUSIVE Page 1 of Front Right Burner (NG) TECHNICAL DETAILS Circuit Breaker (A) Volts (V) Frequency (Hz) Plug Type / Receptacle Power Cord Length (in) Energy Source Gas...
PCG366W 36-INCH GAS RANGETOP PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE FEATURES & BENEFITS - Patented Pedestal Star® Burner with QuickClean Base® designed for easy surface cleaning and ... size pan - Precision simmering capabilities as low as 100°F (375 BTU) with 2 ExtraLow® Simmer burners - LED Downlighting - to Combustible Surface 142 lbs 2 Year THERMADOR® EXCLUSIVE Page 1 of Front Right Burner (NG) TECHNICAL DETAILS Circuit Breaker (A) Volts (V) Frequency (Hz) Plug Type / Receptacle Power Cord Length (in) Energy Source Gas...
Product Spec Sheet
Page 2
PCG366W 36-INCH GAS RANGETOP PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE ACCESSORIES (OPTIONAL) PAGRIDDLE Griddle Sits on Top of Grates Over 2 Star Burners PA36WLBC 10" Low Backguard 36" RANGETOP SIDE VIEW PA12CHPBLK 12" Cutting Board PAKNOBLUWR Metallic Blue Knob Kit PWOKRINGHC Wok Ring PALPKITHW LP Conversion Kit, Pro Rangetops (4 & 6 Burners) Page 2 of 5 10 / 19
PCG366W 36-INCH GAS RANGETOP PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE ACCESSORIES (OPTIONAL) PAGRIDDLE Griddle Sits on Top of Grates Over 2 Star Burners PA36WLBC 10" Low Backguard 36" RANGETOP SIDE VIEW PA12CHPBLK 12" Cutting Board PAKNOBLUWR Metallic Blue Knob Kit PWOKRINGHC Wok Ring PALPKITHW LP Conversion Kit, Pro Rangetops (4 & 6 Burners) Page 2 of 5 10 / 19
Product Spec Sheet
Page 4
... junction box must be located within 3 feet (~900 mm) of the rangetop connection. NATURAL GAS REQUIREMENTS: Inlet Connection: 1/2" NPT (min. 3/4" dia. PCG366W 36-INCH GAS RANGETOP PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE 36-INCH RANGETOP GAS LOCATION The gas and electrical supply must be located in an area that is equipped with all-burner...
... junction box must be located within 3 feet (~900 mm) of the rangetop connection. NATURAL GAS REQUIREMENTS: Inlet Connection: 1/2" NPT (min. 3/4" dia. PCG366W 36-INCH GAS RANGETOP PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE 36-INCH RANGETOP GAS LOCATION The gas and electrical supply must be located in an area that is equipped with all-burner...
Product Spec Sheet
Page 5
...cabinet. Specifications are certified for your specific ventilation requirements. for use in Canada. 1 800 735 4328 | USA THERMADOR.COM | CANADA THERMADOR.CA | ©2019 BSH HOME APPLIANCES CORPORATION. Specifications are for products that vary from date of a flame ...steel, 0.024 inch (0.6 mm) aluminum, or 0.020 inch (0.5 mm) thick copper. PCG366W 36-INCH GAS RANGETOP PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE 36-INCH RANGETOP CLEARANCES NOTE: A 36-inch minimum clearance is not responsible for planning purposes only. Refer to installation instructions and consult...
...cabinet. Specifications are certified for your specific ventilation requirements. for use in Canada. 1 800 735 4328 | USA THERMADOR.COM | CANADA THERMADOR.CA | ©2019 BSH HOME APPLIANCES CORPORATION. Specifications are for products that vary from date of a flame ...steel, 0.024 inch (0.6 mm) aluminum, or 0.020 inch (0.5 mm) thick copper. PCG366W 36-INCH GAS RANGETOP PROFESSIONAL SERIES, PORCELAIN COOKTOP SURFACE 36-INCH RANGETOP CLEARANCES NOTE: A 36-inch minimum clearance is not responsible for planning purposes only. Refer to installation instructions and consult...
Installation Instructions
Page 5
... or use an extension cord. • Improper grounding can result in death, fire, or electrical shock. Local codes vary. This appliance must be longer than 36'' (914 mm). Only the standard top burners can result in a risk of such codes, with the National Electrical Code, NFPA 70 latest edition, or the...
... or use an extension cord. • Improper grounding can result in death, fire, or electrical shock. Local codes vary. This appliance must be longer than 36'' (914 mm). Only the standard top burners can result in a risk of such codes, with the National Electrical Code, NFPA 70 latest edition, or the...
Installation Instructions
Page 7
...combustible materials (i.e. Ventilation preparation To prepare for approved ventilation combinations. a wood covering), it meets local building codes. This type of 36'' (914 mm) above the range cooking surface. • If the hood contains any restriction. Consider make-up to 194 °... • Due to the high volume of ventilation air, a source of the rangetop burners, installing a microwave oven with a Thermador vent hood. Ventilation hoods and blowers are recommended for use with the manufacturer to ensure materials meet local requirements. Where space permits,...
...combustible materials (i.e. Ventilation preparation To prepare for approved ventilation combinations. a wood covering), it meets local building codes. This type of 36'' (914 mm) above the range cooking surface. • If the hood contains any restriction. Consider make-up to 194 °... • Due to the high volume of ventilation air, a source of the rangetop burners, installing a microwave oven with a Thermador vent hood. Ventilation hoods and blowers are recommended for use with the manufacturer to ensure materials meet local requirements. Where space permits,...
Installation Instructions
Page 8
...installation manual for recommended hood options. Another alternative would be necessary to the combustible surface. It should be 18'' (45.7 cm) above the 36'' (914 mm) counter height. • Within the 5'' (127 mm) side clearance to the unit. REAR CLEARANCE REQUIREMENTS: • To... included Island Trim a minimum 6" (152 mm)* rear clearance is required to a combustible surface*. • When installing against a combustible surface, a Thermador® Low Backguard is protected by not less than 1/4'' (6 mm) of a flame retardant material covered with not less than 6'' (152 mm) should...
...installation manual for recommended hood options. Another alternative would be necessary to the combustible surface. It should be 18'' (45.7 cm) above the 36'' (914 mm) counter height. • Within the 5'' (127 mm) side clearance to the unit. REAR CLEARANCE REQUIREMENTS: • To... included Island Trim a minimum 6" (152 mm)* rear clearance is required to a combustible surface*. • When installing against a combustible surface, a Thermador® Low Backguard is protected by not less than 1/4'' (6 mm) of a flame retardant material covered with not less than 6'' (152 mm) should...
Installation Instructions
Page 12
... D Detail A 2213/16" (580) A inches (mm) Detail A: front face of cabinet C B Corner Notch Detail 2 x 4 Corner Support 7 11/16" (195) inches (mm) inches (mm) 30'' Rangetop 36'' Rangetop 48'' Rangetop A 29-15/16'' (760 mm) 35-15/16'' (913 mm) 47-15/16'' (1,218 mm) B 3/8'' (10 mm) 3/8'' (10 mm) 7/8'' (22 mm) 0'' (0 mm...
... D Detail A 2213/16" (580) A inches (mm) Detail A: front face of cabinet C B Corner Notch Detail 2 x 4 Corner Support 7 11/16" (195) inches (mm) inches (mm) 30'' Rangetop 36'' Rangetop 48'' Rangetop A 29-15/16'' (760 mm) 35-15/16'' (913 mm) 47-15/16'' (1,218 mm) B 3/8'' (10 mm) 3/8'' (10 mm) 7/8'' (22 mm) 0'' (0 mm...
Installation Instructions
Page 13
...with projecting control panel. 22½" (573) 1½" (38) Cabinet face for the purpose of shutting off the gas supply. Installation of rangetop above Thermador warming drawers 7 5/8" (194) Plywood support Install additional wood support along front edge of gas inlet 6-3/8'' 11" (267 mm) (152 mm) From rear... to reduce the rangetop's weight. Page. 11 Gas Inlet Location 30'' 36'' 48'' From left side to centerline of cutout 2¾" (70) min. Ensure that you have sharp edges. inches (mm) Gas inlet location A ...
...with projecting control panel. 22½" (573) 1½" (38) Cabinet face for the purpose of shutting off the gas supply. Installation of rangetop above Thermador warming drawers 7 5/8" (194) Plywood support Install additional wood support along front edge of gas inlet 6-3/8'' 11" (267 mm) (152 mm) From rear... to reduce the rangetop's weight. Page. 11 Gas Inlet Location 30'' 36'' 48'' From left side to centerline of cutout 2¾" (70) min. Ensure that you have sharp edges. inches (mm) Gas inlet location A ...