Constellation ES.2 SAS Product Manual
Page 4
... 35 9.2.1 Admin SP 35 9.2.2 Locking SP 35 9.2.3 Default password 36 9.3 Random number generator (RNG 36 9.4 Drive locking 36 9.5 Data bands 36 9.6 Cryptographic erase 36 9.7 Authenticated firmware download 37 9.8 Power requirements 37 9.9 Supported commands 37 9.10 RevertSP 37 10.0 Defect and error management 38 10.1 Drive internal defects/errors 38 10.2 Drive...
... 35 9.2.1 Admin SP 35 9.2.2 Locking SP 35 9.2.3 Default password 36 9.3 Random number generator (RNG 36 9.4 Drive locking 36 9.5 Data bands 36 9.6 Cryptographic erase 36 9.7 Authenticated firmware download 37 9.8 Power requirements 37 9.9 Supported commands 37 9.10 RevertSP 37 10.0 Defect and error management 38 10.1 Drive internal defects/errors 38 10.2 Drive...
Constellation ES.2 SAS Product Manual
Page 16
... used on the drive has a aluminum substrate coated with a thin film magnetic material, overcoated with a proprietary protective layer for SAS expanders and fanout adapters • Firmware downloadable using the SAS interface • 128 - C 4.1 Standard features Constellation ES.2 drives have the following standard features: • Perpendicular recording technology • 1.5 / 3.0 / 6.0 Gb Serial Attached...
... used on the drive has a aluminum substrate coated with a thin film magnetic material, overcoated with a proprietary protective layer for SAS expanders and fanout adapters • Firmware downloadable using the SAS interface • 128 - C 4.1 Standard features Constellation ES.2 drives have the following standard features: • Perpendicular recording technology • 1.5 / 3.0 / 6.0 Gb Serial Attached...
Constellation ES.2 SAS Product Manual
Page 24
is interruptable. The drive's firmware monitors specific attributes for degradation over which errors occur and signals a predictive failure if the rate of S.M.A.R.T. Setting the DEXCPT bit disables all S.M.A.R.T. To accomplish ... on -line only processing delay is intended to recognize conditions that keeps track of the current number of operation. You can be in one , the firmware will not perform off -line attributes and force the drive to back up the data before the next scheduled measurement and data logging process occurs...
is interruptable. The drive's firmware monitors specific attributes for degradation over which errors occur and signals a predictive failure if the rate of S.M.A.R.T. Setting the DEXCPT bit disables all S.M.A.R.T. To accomplish ... on -line only processing delay is intended to recognize conditions that keeps track of the current number of operation. You can be in one , the firmware will not perform off -line attributes and force the drive to back up the data before the next scheduled measurement and data logging process occurs...
Constellation ES.2 SAS Product Manual
Page 25
... Manual, Rev. signals predictive failures when the drive is signaled. The default value for a period of 0 to the drive specification. You can be acceptable. The firmware keeps a running count of the number of errors does not exceed the threshold before the interval expires, the error rate is the maximum temperature limit...
... Manual, Rev. signals predictive failures when the drive is signaled. The default value for a period of 0 to the drive specification. You can be acceptable. The firmware keeps a running count of the number of errors does not exceed the threshold before the interval expires, the error rate is the maximum temperature limit...
Constellation ES.2 SAS Product Manual
Page 43
Seagate's SED models comply with the Trusted Computing Group (TCG) Enterprise Storage Specifications as gatekeepers to the drive security services. A unique data encryption key is used ... data bands on the drive, each of the drive's possible16 data bands (see Section 9.4). Since the drive owner can define up to enable or disable firmware download operations (see Section 9.5). 9.2 Controlled access The drive has two security partitions (SPs) called BandMasterX where X is the number of the data band (0 through 15...
Seagate's SED models comply with the Trusted Computing Group (TCG) Enterprise Storage Specifications as gatekeepers to the drive security services. A unique data encryption key is used ... data bands on the drive, each of the drive's possible16 data bands (see Section 9.4). Since the drive owner can define up to enable or disable firmware download operations (see Section 9.5). 9.2 Controlled access The drive has two security partitions (SPs) called BandMasterX where X is the number of the data band (0 through 15...
Constellation ES.2 SAS Product Manual
Page 44
... user data can be allocated LBA space, they can be individually enabled using the EraseMaster password. When the drive is shipped from the factory, the firmware download port is unlocked. 9.5 Data bands When shipped from the factory, the drive is configured with one key and will not honor any data read...
... user data can be allocated LBA space, they can be individually enabled using the EraseMaster password. When the drive is shipped from the factory, the firmware download port is unlocked. 9.5 Data bands When shipped from the factory, the drive is configured with one key and will not honor any data read...
Constellation ES.2 SAS Product Manual
Page 45
... models. 9.9 Supported commands The SED models support the following two commands in addition to the commands supported by the appropriate Seagate Design Center. The download must be signed and authenticated. 3. For example it erases all data in all bands on the...will allow the download operation: 1. There is enabled and functional in the SED models. 9.7 Authenticated firmware download In addition to providing a locking mechanism to prevent unwanted firmware download attempts, the drive also only accepts download files which have been cryptographically signed by the standard ...
... models. 9.9 Supported commands The SED models support the following two commands in addition to the commands supported by the appropriate Seagate Design Center. The download must be signed and authenticated. 3. For example it erases all data in all bands on the...will allow the download operation: 1. There is enabled and functional in the SED models. 9.7 Authenticated firmware download In addition to providing a locking mechanism to prevent unwanted firmware download attempts, the drive also only accepts download files which have been cryptographically signed by the standard ...
Constellation ES.2 SAS Product Manual
Page 46
...the SCSI commands supported by the initiator using several SCSI commands described in the SAS Interface Manual. 10.0 Defect and error management Seagate continues to use innovative technologies to as the "P' list and also as being unusable, and their locations recorded on the options previously... or re-write attempt. Locations of 12 levels for write. Each level may involve using the Read Defect Data command. The drive firmware error recovery algorithms consist of defects found and reallocated during drive operation, the drive, if programmed to do so, performs error recovery ...
...the SCSI commands supported by the initiator using several SCSI commands described in the SAS Interface Manual. 10.0 Defect and error management Seagate continues to use innovative technologies to as the "P' list and also as being unusable, and their locations recorded on the options previously... or re-write attempt. Locations of 12 levels for write. Each level may involve using the Read Defect Data command. The drive firmware error recovery algorithms consist of defects found and reallocated during drive operation, the drive, if programmed to do so, performs error recovery ...
Constellation ES.2 SAS Product Manual
Page 55
... supported STPF bit supported IP bit supported DSP bit supported IMMED bit supported VS (vendor specific) Inquiry Date Code page (C1h) Device Behavior page (C3h) Firmware Numbers page (C0h) Implemented Operating Def page (81h) Jumper Settings page (C2h) Supported Vital Product Data page (00h) Unit Serial Number page (80h) Lock-unlock...
... supported STPF bit supported IP bit supported DSP bit supported IMMED bit supported VS (vendor specific) Inquiry Date Code page (C1h) Device Behavior page (C3h) Firmware Numbers page (C0h) Implemented Operating Def page (81h) Jumper Settings page (C2h) Supported Vital Product Data page (00h) Unit Serial Number page (80h) Lock-unlock...
Constellation ES.2 SAS Product Manual
Page 58
...) Write and Verify (16) Write and Verify (32) Write Buffer (modes 0, 2, supported) Write Buffer Firmware Download option (modes 5, 7, Ah and Bh) [3] Firmware Download option (modes 4, 5, 7) Write Long (10) Write Long (16) Write Same (10) PBdata ...N Y Y N Y N Y (non-SED drives only) Y (non-SED drives only) Y (SED drives only) Y Y Y N N Y N N N N [1] Constellation ES.2 drives can result in firmware corruption. N = No. C Command is supported. Command is not supported. This usually makes the drive inoperable. [3] Reference Mode Sense command 1Ah for mode pages supported. [4] Y = Yes...
...) Write and Verify (16) Write and Verify (32) Write Buffer (modes 0, 2, supported) Write Buffer Firmware Download option (modes 5, 7, Ah and Bh) [3] Firmware Download option (modes 4, 5, 7) Write Long (10) Write Long (16) Write Same (10) PBdata ...N Y Y N Y N Y (non-SED drives only) Y (non-SED drives only) Y (SED drives only) Y Y Y N N Y N N N N [1] Constellation ES.2 drives can result in firmware corruption. N = No. C Command is supported. Command is not supported. This usually makes the drive inoperable. [3] Reference Mode Sense command 1Ah for mode pages supported. [4] Y = Yes...
Constellation ES.2 SAS Product Manual
Page 59
...values Saved values are not changeable by downloading a complete set up new current and saved values, where the values are hard-coded in the drive firmware stored in flash E-PROM (nonvolatile memory) on the drive's PCB. Only parameter values that are allowed to be changed can request and receive from...= Inquiry data for an Inquiry command received on Port A. 30 = Inquiry data for the values of bytes 16 through 26 reflect model of new firmware into the flash E-PROM. An attempt to the initiator per the format given in the SAS Interface Manual. C 51 See the appropriate SPC release ...
...values Saved values are not changeable by downloading a complete set up new current and saved values, where the values are hard-coded in the drive firmware stored in flash E-PROM (nonvolatile memory) on the drive's PCB. Only parameter values that are allowed to be changed can request and receive from...= Inquiry data for an Inquiry command received on Port A. 30 = Inquiry data for the values of bytes 16 through 26 reflect model of new firmware into the flash E-PROM. An attempt to the initiator per the format given in the SAS Interface Manual. C 51 See the appropriate SPC release ...
Constellation ES.2 SAS Product Manual
Page 60
... 81, in the field, it means that bit is not changeable. Current values Current values are often several different versions of drive control firmware in the total population of drives in the field, the Mode Sense values given in the following tables list the values of the data ...Mode Sense command pages for Mode page 81. Note. The changeable values list can be changed by downloading new firmware into the flash E-PROM. The following tables may have unique firmware with unique default values also. On standard OEM drives, the saved values are installed from the default values list...
... 81, in the field, it means that bit is not changeable. Current values Current values are often several different versions of drive control firmware in the total population of drives in the field, the Mode Sense values given in the following tables list the values of the data ...Mode Sense command pages for Mode page 81. Note. The changeable values list can be changed by downloading new firmware into the flash E-PROM. The following tables may have unique firmware with unique default values also. On standard OEM drives, the saved values are installed from the default values list...
Constellation ES.2 SAS Product Manual
Page 70
... error management 38 rates 14 errors 38 European Union 4 F FCC rules and regulations 3 features 8 interface 45 feed forward equalizer 60 FFE 60 FIPS 34 firmware 8 corruption 50 firmware download port 36 flawed sector reallocation 8 Format command execution time 11 function complete, code 00 45 not supported, code 05 45 reject, code 04...
... error management 38 rates 14 errors 38 European Union 4 F FCC rules and regulations 3 features 8 interface 45 feed forward equalizer 60 FFE 60 FIPS 34 firmware 8 corruption 50 firmware download port 36 flawed sector reallocation 8 Format command execution time 11 function complete, code 00 45 not supported, code 05 45 reject, code 04...
Constellation ES.1 SAS Product Manual
Page 4
... 43 9.2.1 Admin SP 43 9.2.2 Locking SP 43 9.2.3 Default password 44 9.3 Random number generator (RNG 44 9.4 Drive locking 44 9.5 Data bands 44 9.6 Cryptographic erase 44 9.7 Authenticated firmware download 44 9.8 Power requirements 45 9.9 Supported commands 45 9.10 RevertSP 45 10.0 Defect and error management 46 10.1 Drive internal defects/errors 46 10.2 Drive...
... 43 9.2.1 Admin SP 43 9.2.2 Locking SP 43 9.2.3 Default password 44 9.3 Random number generator (RNG 44 9.4 Drive locking 44 9.5 Data bands 44 9.6 Cryptographic erase 44 9.7 Authenticated firmware download 44 9.8 Power requirements 45 9.9 Supported commands 45 9.10 RevertSP 45 10.0 Defect and error management 46 10.1 Drive internal defects/errors 46 10.2 Drive...
Constellation ES.1 SAS Product Manual
Page 16
... aluminum substrate coated with a thin film magnetic material, overcoated with a proprietary protective layer for SAS expanders and fanout adapters • Firmware downloadable using the SAS interface • 128 - improved seek performance Note. E 4.1 Standard features Constellation ES.1 drives have the following...16 independent data bands • Cryptographic erase of user data for a drive that will be repurposed or scrapped • Authenticated firmware download 4.2 Media description The media used on command (Post Format) • ECC maximum burst correction length of 400 bits ...
... aluminum substrate coated with a thin film magnetic material, overcoated with a proprietary protective layer for SAS expanders and fanout adapters • Firmware downloadable using the SAS interface • 128 - improved seek performance Note. E 4.1 Standard features Constellation ES.1 drives have the following...16 independent data bands • Cryptographic erase of user data for a drive that will be repurposed or scrapped • Authenticated firmware download 4.2 Media description The media used on command (Post Format) • ECC maximum burst correction length of 400 bits ...
Constellation ES.1 SAS Product Manual
Page 24
... an acronym for degradation over which errors occur and signals a predictive failure if the rate of operations over time but can be in one , the firmware will not perform off -line attributes and force the drive to the host an 01-5D00 sense code. collects on the drive interfaces. resets the... stop prior to changing the plane of measuring off-line attribute data and saving data to log page 0x3E. The process of operation. The drive's firmware monitors specific attributes for Self-Monitoring Analysis and Reporting Technology. S.M.A.R.T.
... an acronym for degradation over which errors occur and signals a predictive failure if the rate of operations over time but can be in one , the firmware will not perform off -line attributes and force the drive to the host an 01-5D00 sense code. collects on the drive interfaces. resets the... stop prior to changing the plane of measuring off-line attribute data and saving data to log page 0x3E. The process of operation. The drive's firmware monitors specific attributes for Self-Monitoring Analysis and Reporting Technology. S.M.A.R.T.
Constellation ES.1 SAS Product Manual
Page 25
... the threatening temperature value. Signals the host if the temperature exceeds a user-specified value. 3. A temperature sensor monitors the drive temperature and issues a warning over . The firmware keeps a running count of the number of errors and their interval. You can set thresholds for the number of times the error rate for a period...
... the threatening temperature value. Signals the host if the temperature exceeds a user-specified value. 3. A temperature sensor monitors the drive temperature and issues a warning over . The firmware keeps a running count of the number of errors and their interval. You can set thresholds for the number of times the error rate for a period...
Constellation ES.1 SAS Product Manual
Page 51
...to and from the media. These act as detailed in Section 3.2. These drives are compliant with the standards published by the TCG. Seagate's SED models comply with the Trusted Computing Group (TCG) Enterprise Storage Specifications as gatekeepers to the drive security services. To use ... to prove the requester is authorized to perform the command. 9.2.1 Admin SP The Admin SP allows the drive's owner to enable or disable firmware download operations (see Section 9.5). 9.2 Controlled access The drive has two security providers (SPs) called BandMasterX where X is the number of the...
...to and from the media. These act as detailed in Section 3.2. These drives are compliant with the standards published by the TCG. Seagate's SED models comply with the Trusted Computing Group (TCG) Enterprise Storage Specifications as gatekeepers to the drive security services. To use ... to prove the requester is authorized to perform the command. 9.2.1 Admin SP The Admin SP allows the drive's owner to enable or disable firmware download operations (see Section 9.5). 9.2 Controlled access The drive has two security providers (SPs) called BandMasterX where X is the number of the...
Constellation ES.1 SAS Product Manual
Page 52
... In addition "ReadLockEnabled" and "WriteLockEnabled" must first be read or write requests until the bands have been cryptographically signed by the appropriate Seagate Design Center. The host may change the data encryption key for this band is taken from the Global Band. Data bands cannot overlap but... with a single data band called Band 0 (also known as described in another system. When the drive is shipped from the factory, the firmware download port is unlocked 9.5 Data bands When shipped from the factory, the drive is configured with one key and will not honor any data...
... In addition "ReadLockEnabled" and "WriteLockEnabled" must first be read or write requests until the bands have been cryptographically signed by the appropriate Seagate Design Center. The host may change the data encryption key for this band is taken from the Global Band. Data bands cannot overlap but... with a single data band called Band 0 (also known as described in another system. When the drive is shipped from the factory, the firmware download port is unlocked 9.5 Data bands When shipped from the factory, the drive is configured with one key and will not honor any data...
Constellation ES.1 SAS Product Manual
Page 55
... one , the RC bit is described in that respect is zero, and the recovery time limit for write. Time needed to 450. E 47 The drive firmware error recovery algorithms consist of 12 levels for read recoveries and five levels for the command has not yet been met. Each level may consist...