Hardware Manual
Page 3
... 5 NEC / Plantronics Headsets 5 GN Netcom Headsets 8 Headsets for DSX Cordless Lite II Telephone 9 DESI Telephone Label System 10 DESI Plus Labeling Software 10 DESI Telephone Labels 11 DSX-40 Common Equipment 12 DSX-40 4x8x2 Key Telephone System with 2 Door Box Ports and Caller-ID 12 DSX-40 PCBs 13 DSX-40 8-Port Digital Station (8ESIU) Card 13 Expansion Guidelines 13 DSX-40 8-Port Analog...
... 5 NEC / Plantronics Headsets 5 GN Netcom Headsets 8 Headsets for DSX Cordless Lite II Telephone 9 DESI Telephone Label System 10 DESI Plus Labeling Software 10 DESI Telephone Labels 11 DSX-40 Common Equipment 12 DSX-40 4x8x2 Key Telephone System with 2 Door Box Ports and Caller-ID 12 DSX-40 PCBs 13 DSX-40 8-Port Digital Station (8ESIU) Card 13 Expansion Guidelines 13 DSX-40 8-Port Analog...
Hardware Manual
Page 4
... Ground Wire 23 Removing the Top Panel 24 Top Panel Removal 24 Installing Expansion Cards, the Battery, and Replacement Fuses 25 Installing Expansion Cards 25 Station Cards 25 Line Card 25 Installing and Replacing the Battery 26 Power Supply AC Input Fuses 27 ...DSX Analog Door Box to the 2PGDAD Module 51 Preparation 51 Connecting PGDAD Door Boxes and Relays 52 Mounting the 2PGDAD Module and Connecting to the System 53 External Paging 54 Installing External Paging 54 Music Source 55 Installing a Music Source 55 Power Failure Telephone 56 ii ◆ Table of Contents DSX-40...
... Ground Wire 23 Removing the Top Panel 24 Top Panel Removal 24 Installing Expansion Cards, the Battery, and Replacement Fuses 25 Installing Expansion Cards 25 Station Cards 25 Line Card 25 Installing and Replacing the Battery 26 Power Supply AC Input Fuses 27 ...DSX Analog Door Box to the 2PGDAD Module 51 Preparation 51 Connecting PGDAD Door Boxes and Relays 52 Mounting the 2PGDAD Module and Connecting to the System 53 External Paging 54 Installing External Paging 54 Music Source 55 Installing a Music Source 55 Power Failure Telephone 56 ii ◆ Table of Contents DSX-40...
Hardware Manual
Page 18
...Ports: 40 Ethernet port: Yes (auto sensing) Analog line ports: Built-in: 4 Total: 8 Expansion slots: Station expansion slots: 2 Line expansion slots:1 Audio outputs: 1 Audio inputs: 2 CompactFlash interface: Yes USB connector: Yes DSX-40 is a compact, wall-mountable, more . 12 ◆ Components DSX-40 Hardware ... (when held down for a few seconds while a software update CompactFlash card is easily expandable by adding station and line PCBs. Additionally, the basic DSX-40 provides: • CompactFlash card interface (for IntraMail, software loading, and database backup) • Conference...
...Ports: 40 Ethernet port: Yes (auto sensing) Analog line ports: Built-in: 4 Total: 8 Expansion slots: Station expansion slots: 2 Line expansion slots:1 Audio outputs: 1 Audio inputs: 2 CompactFlash interface: Yes USB connector: Yes DSX-40 is a compact, wall-mountable, more . 12 ◆ Components DSX-40 Hardware ... (when held down for a few seconds while a software update CompactFlash card is easily expandable by adding station and line PCBs. Additionally, the basic DSX-40 provides: • CompactFlash card interface (for IntraMail, software loading, and database backup) • Conference...
Hardware Manual
Page 19
... top or middle DSX-40 expansion slot. You can install up to two 8-Port Digital Station Cards, using the upper and middle expansion slots, for a system maximum of 18 analog stations. Top Position (9-16) 8-Port Digital Card 8-Port Digital Card 8-Port Analog Card DSX-40 Station Card Capacities Middle Position (17-14) 8-Port Digital Card 8-Port Analog Card 8-Port Analog Card Total 24 Digital and 2 Analog 16 Digital and...
... top or middle DSX-40 expansion slot. You can install up to two 8-Port Digital Station Cards, using the upper and middle expansion slots, for a system maximum of 18 analog stations. Top Position (9-16) 8-Port Digital Card 8-Port Digital Card 8-Port Analog Card DSX-40 Station Card Capacities Middle Position (17-14) 8-Port Digital Card 8-Port Analog Card 8-Port Analog Card Total 24 Digital and 2 Analog 16 Digital and...
Hardware Manual
Page 20
... ID. Caller ID: Built in Message Waiting: FSK only The 4-Port CO Line Card with Caller ID is an expansion card that provides four additional CO line ports with built-in the bottom expansion slot. 14 ◆ Components DSX-40 Hardware Manual line cards installed: 1 (4 additional CO line ports) Max. Tips to remember: • You can install...
... ID. Caller ID: Built in Message Waiting: FSK only The 4-Port CO Line Card with Caller ID is an expansion card that provides four additional CO line ports with built-in the bottom expansion slot. 14 ◆ Components DSX-40 Hardware Manual line cards installed: 1 (4 additional CO line ports) Max. Tips to remember: • You can install...
Hardware Manual
Page 30
Lift up the top panel as shown below. 3. Remove the top panel. 2 3 1 1093097 - 5 24 ◆ Installation Figure 5: Removing the Top Panel DSX-40 Hardware Manual To remove the top panel: 1. Be sure your system's power cord is unplugged, then unscrew the 2 captive screws that secure the cabinet top panel to replace the power supply AC input fuses. Removing the Top Panel Removing the Top Panel Top Panel Removal You must remove the top panel in order to install the system battery and Expansion Cards (if required), or to the base. 2.
Lift up the top panel as shown below. 3. Remove the top panel. 2 3 1 1093097 - 5 24 ◆ Installation Figure 5: Removing the Top Panel DSX-40 Hardware Manual To remove the top panel: 1. Be sure your system's power cord is unplugged, then unscrew the 2 captive screws that secure the cabinet top panel to replace the power supply AC input fuses. Removing the Top Panel Removing the Top Panel Top Panel Removal You must remove the top panel in order to install the system battery and Expansion Cards (if required), or to the base. 2.
Hardware Manual
Page 31
... combination. This allows you can install them in either position in Caller ID. Top Position (9-16) 8-Port Digital Card 8-Port Digital Card 8-Port Analog Card DSX-40 Station Card Capacities Middle Position (17-14) 8-Port Digital Card 8-Port Analog Card 8-Port Analog Card Total 24 Digital and 2 Analog 16 Digital and 10 Analog 8 Digital and 18 Analog Line Card The bottom expansion position is reserved for lines.
... combination. This allows you can install them in either position in Caller ID. Top Position (9-16) 8-Port Digital Card 8-Port Digital Card 8-Port Analog Card DSX-40 Station Card Capacities Middle Position (17-14) 8-Port Digital Card 8-Port Analog Card 8-Port Analog Card Total 24 Digital and 2 Analog 16 Digital and 10 Analog 8 Digital and 18 Analog Line Card The bottom expansion position is reserved for lines.
Hardware Manual
Page 32
Installing Expansion Cards, the Battery, and Replacement Fuses Installing and Replacing the Battery In the event of commercial AC power failure, the battery provides short-term (14 day) backup of the Real Time Clock and station parameters. Insert the battery into the battery clips as required. Replace and re-secure the top panel. OR Go to Installing Expansion Cards (page 25) and install Expansion Cards as shown below. 2. To install the battery: 1. Battery Figure 7: Installing the Battery 1093097 - 6 26 ◆ Installation DSX-40 Hardware Manual
Installing Expansion Cards, the Battery, and Replacement Fuses Installing and Replacing the Battery In the event of commercial AC power failure, the battery provides short-term (14 day) backup of the Real Time Clock and station parameters. Insert the battery into the battery clips as required. Replace and re-secure the top panel. OR Go to Installing Expansion Cards (page 25) and install Expansion Cards as shown below. 2. To install the battery: 1. Battery Figure 7: Installing the Battery 1093097 - 6 26 ◆ Installation DSX-40 Hardware Manual
Hardware Manual
Page 33
... type: Cooper/Bussman Type BK/S501 Rated 6.3A/250V Ceramic DSX-40 Hardware Manual Installation ◆ 27 able from problems with the same... no longer backs up station parameters and the Real Time Clock). 1. To replace a fuse: 1. Installation Installing Expansion Cards, the Battery, and Replacement Fuses To replace an existing battery: You should never need to replace your system's ... Power Supply AC Input Fuses The power supply AC input fuses protect the system power supply from NEC as P/N EX0254-0040.) 4. Verify that the Real Time Clock and station parameters data is intact....
... type: Cooper/Bussman Type BK/S501 Rated 6.3A/250V Ceramic DSX-40 Hardware Manual Installation ◆ 27 able from problems with the same... no longer backs up station parameters and the Real Time Clock). 1. To replace a fuse: 1. Installation Installing Expansion Cards, the Battery, and Replacement Fuses To replace an existing battery: You should never need to replace your system's ... Power Supply AC Input Fuses The power supply AC input fuses protect the system power supply from NEC as P/N EX0254-0040.) 4. Verify that the Real Time Clock and station parameters data is intact....
Hardware Manual
Page 34
... line expansion card installed in the top position. The Main Equipment Cabinet provides 8-pin mod jacks for connecting extensions and lines. To connect all 26 extensions and 8 lines, you'll need 3 installation cables and 3 associated 66M1-50 connecting blocks. STA 9-12 First 4 station ports in the bottom position. 28 ◆ Installation DSX-40 Hardware...
... line expansion card installed in the top position. The Main Equipment Cabinet provides 8-pin mod jacks for connecting extensions and lines. To connect all 26 extensions and 8 lines, you'll need 3 installation cables and 3 associated 66M1-50 connecting blocks. STA 9-12 First 4 station ports in the bottom position. 28 ◆ Installation DSX-40 Hardware...
Hardware Manual
Page 39
... (3T) GRN-WHT (3R) WHT-BRN (4T) BRN-WHT (4R) Figure 13: 8-Pin (RJ61X) Jack Pinouts Connecting Extensions A fully expanded DSX-40 can connect up to leave a service loop in an RJ61X configuration. Using Figure 9: Punch Down for more. To make your local supplier ...BLU/WHT leads to the modular jack. - See Installing Expansion Cards (page 25) for Extensions (page 30) as a guide, plug the installation cable plugs into the appropriate jacks on the combination of 8-Port Digital Station and 8-Port Analog Station Cards installed. Install bridging clips as a RJ45 connector wired ...
... (3T) GRN-WHT (3R) WHT-BRN (4T) BRN-WHT (4R) Figure 13: 8-Pin (RJ61X) Jack Pinouts Connecting Extensions A fully expanded DSX-40 can connect up to leave a service loop in an RJ61X configuration. Using Figure 9: Punch Down for more. To make your local supplier ...BLU/WHT leads to the modular jack. - See Installing Expansion Cards (page 25) for Extensions (page 30) as a guide, plug the installation cable plugs into the appropriate jacks on the combination of 8-Port Digital Station and 8-Port Analog Station Cards installed. Install bridging clips as a RJ45 connector wired ...
Hardware Manual
Page 41
...Cable (P/N 808920) Figure 15: Installing Analog Lines 25-Pair Cable to Central Office DSX-40 Hardware Manual Installation ◆ 35 By adding a 4-Port Line Card you can connect up to 8 analog loop-start lines with built-in ...Caller ID. Install bridging clips as a guide, plug the installation cable plugs into the appropriate jacks on the Main Equipment Cabinet. 2. Using Figure 10: Punch Down for more. Connecting Extensions and Lines Connecting Lines A fully expanded DSX-40 can connect the system to 8 lines. See Installing Expansion Cards...
...Cable (P/N 808920) Figure 15: Installing Analog Lines 25-Pair Cable to Central Office DSX-40 Hardware Manual Installation ◆ 35 By adding a 4-Port Line Card you can connect up to 8 analog loop-start lines with built-in ...Caller ID. Install bridging clips as a guide, plug the installation cable plugs into the appropriate jacks on the Main Equipment Cabinet. 2. Using Figure 10: Punch Down for more. Connecting Extensions and Lines Connecting Lines A fully expanded DSX-40 can connect the system to 8 lines. See Installing Expansion Cards...
Hardware Manual
Page 72
... established environmental standards maximizes the life of 2) Music Inputs: 2 Conference Circuits: 8-Port Digital Station Card (Expansion) 8-Port Analog Station Card (Expansion) 4-Port Line Card with Built-In Caller ID (Expansion) 32 Conference circuits dynamically allocated, with 8 parties max per Conference. Near radio antennas (including shortwave...of -20 to 60 degrees C (-4 to 95% (non-condensing) DSX Analog Door Box The Analog Door Box is a weather-tight unit, with the main equipment. 5. Specifications DSX-40 System Capacities (Page 2 of the system. Be sure that the ...
... established environmental standards maximizes the life of 2) Music Inputs: 2 Conference Circuits: 8-Port Digital Station Card (Expansion) 8-Port Analog Station Card (Expansion) 4-Port Line Card with Built-In Caller ID (Expansion) 32 Conference circuits dynamically allocated, with 8 parties max per Conference. Near radio antennas (including shortwave...of -20 to 60 degrees C (-4 to 95% (non-condensing) DSX Analog Door Box The Analog Door Box is a weather-tight unit, with the main equipment. 5. Specifications DSX-40 System Capacities (Page 2 of the system. Be sure that the ...
Hardware Manual
Page 79
... Description See Headsets (page 5). Common Equipment Description DSX-40 DSX-40 Main Equipment Cabinet Additional Common Equipment Installation Cable DSX SMDR Adaptor (requires customer-provided 6-conductor line cord) Cards Description DSX-40 8-Port Digital Station Card (Expansion) 8-Port Analog Station Card (Expansion) 4-Port Line Card with Built-In Caller ID (Expansion) Description IntraMail 8 Port x 16 Hour IntraMail 4 Port x 8 Hour IntraMail Parts List Part Number Part...
... Description See Headsets (page 5). Common Equipment Description DSX-40 DSX-40 Main Equipment Cabinet Additional Common Equipment Installation Cable DSX SMDR Adaptor (requires customer-provided 6-conductor line cord) Cards Description DSX-40 8-Port Digital Station Card (Expansion) 8-Port Analog Station Card (Expansion) 4-Port Line Card with Built-In Caller ID (Expansion) Description IntraMail 8 Port x 16 Hour IntraMail 4 Port x 8 Hour IntraMail Parts List Part Number Part...