Specification Sheet
Page 1
...Enhanced Dryer Maytag®... & Care Guide Warranty *Results may vary based on select Maytag® washers to get clothes ready in no time. Specifications...Door Style Side Swing Reversible Door Yes Number of Dryer Cycles Selection of Drying Cycles Dryer Option Selections Dimensions Product Dimensions (H x W ... Drum American Pride 7.3 cu. MED6630HSpecSheetV01. Front Load Electric Dryer MED6630H Chrome Shadow MED6630HC Also available in the U.S.A. For ...the Quick Wash cycle on load size and type. **Visit maytag.com for planning purposes only. Quick Dry Cycle Dry a small...
...Enhanced Dryer Maytag®... & Care Guide Warranty *Results may vary based on select Maytag® washers to get clothes ready in no time. Specifications...Door Style Side Swing Reversible Door Yes Number of Dryer Cycles Selection of Drying Cycles Dryer Option Selections Dimensions Product Dimensions (H x W ... Drum American Pride 7.3 cu. MED6630HSpecSheetV01. Front Load Electric Dryer MED6630H Chrome Shadow MED6630HC Also available in the U.S.A. For ...the Quick Wash cycle on load size and type. **Visit maytag.com for planning purposes only. Quick Dry Cycle Dry a small...
Installation Instructions
Page 3
... Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1. I A flexible gas connector, when used, must be listed. The dryer must not exceed 4 feet (121.9 cm). 3 do not use any phone in your building. • Clear the room, building, or area of all occupants. •...
... Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1. I A flexible gas connector, when used, must be listed. The dryer must not exceed 4 feet (121.9 cm). 3 do not use any phone in your building. • Clear the room, building, or area of all occupants. •...
Installation Instructions
Page 4
... (25 mm) or hex-head socket wrench Wire stripper (direct wire installations) 4 Rubber washer 5' (1.52 m) inlet hose Parts package is located in dryer drum. Check that opens to propane gas Parts supplied (all parts are included. NOTE: Do not use leveling legs supplied with... dryer if installing with dryer): ■■ Vent clamps ■■ Vent elbows and vent work Parts needed (steam models): "Y" connector 2' (0.6 m) inlet hose Caulking gun and compound ...
... (25 mm) or hex-head socket wrench Wire stripper (direct wire installations) 4 Rubber washer 5' (1.52 m) inlet hose Parts package is located in dryer drum. Check that opens to propane gas Parts supplied (all parts are included. NOTE: Do not use leveling legs supplied with... dryer if installing with dryer): ■■ Vent clamps ■■ Vent elbows and vent work Parts needed (steam models): "Y" connector 2' (0.6 m) inlet hose Caulking gun and compound ...
Installation Instructions
Page 5
... information about accessories available for use with upturned ends. ■■ A UL Listed strain relief. Maytag® Models IMPORTANT: Do not operate, install, or store dryer where it will need : ■■ A location allowing for an electric dryer. ■■ If using a power supply cord: Use a UL Listed power supply cord kit marked...
... information about accessories available for use with upturned ends. ■■ A UL Listed strain relief. Maytag® Models IMPORTANT: Do not operate, install, or store dryer where it will need : ■■ A location allowing for an electric dryer. ■■ If using a power supply cord: Use a UL Listed power supply cord kit marked...
Installation Instructions
Page 6
...for exhaust vent with a door, minimum ventilation openings in mobile homes to order. For mobile home installation of 5" (127 mm) clearance behind dryer for Mobile home construction and Safety, Title 24, HUD Part 280) or Standard CAN/CSA-Z240 MH. Check code requirements. Openings (such ... for mobile home installations. NOTE: No other fuel-burning appliance can be considered. 0" (0 mm) rear spacing is suitable for ease of the dryer in your Use and Care Guide. 6 For further information, see "Assistance or Service" in garages, closets, mobile homes, or sleeping quarters. ...
...for exhaust vent with a door, minimum ventilation openings in mobile homes to order. For mobile home installation of 5" (127 mm) clearance behind dryer for Mobile home construction and Safety, Title 24, HUD Part 280) or Standard CAN/CSA-Z240 MH. Check code requirements. Openings (such ... for mobile home installations. NOTE: No other fuel-burning appliance can be considered. 0" (0 mm) rear spacing is suitable for ease of the dryer in your Use and Care Guide. 6 For further information, see "Assistance or Service" in garages, closets, mobile homes, or sleeping quarters. ...
Installation Instructions
Page 7
... Grounding through the neutral conductor is secured under the neutral terminal (center or white wire) of a neutral ground wire to the dryer cabinet with a 3-wire electrical supply connection. The ground wire (ground (14-30R) conductor) may be sure that the ground ... Electrical Code, ANSI/NFPA 70 - latest edition and all mobile home installations. Connect to the neutral conductor (white wire) within the dryer. If the dryer is isolated from : National Fire Protection Association, One Batterymarch Park, Quincy, MA 02269. ■■ To supply the required 3 ...
... Grounding through the neutral conductor is secured under the neutral terminal (center or white wire) of a neutral ground wire to the dryer cabinet with a 3-wire electrical supply connection. The ground wire (ground (14-30R) conductor) may be sure that the ground ... Electrical Code, ANSI/NFPA 70 - latest edition and all mobile home installations. Connect to the neutral conductor (white wire) within the dryer. If the dryer is isolated from : National Fire Protection Association, One Batterymarch Park, Quincy, MA 02269. ■■ To supply the required 3 ...
Installation Instructions
Page 8
...grounding conductor can result in conformance with a UL Listed and/ or CSA International Certified Power Cord intended to whether the dryer is properly grounded. epresentative or personnel if you use Power Supply Cord Replacement Part Number 8529008. 4-wire receptacle (14-30R...recommended that is equipped with a cord having an equipmentgrounding conductor and a grounding plug. GROUNDING INSTRUCTIONS For a grounded, cord-connected dryer: This dryer must be obtained from: Canadian Standards Association, 178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA. ■■ To supply the...
...grounding conductor can result in conformance with a UL Listed and/ or CSA International Certified Power Cord intended to whether the dryer is properly grounded. epresentative or personnel if you use Power Supply Cord Replacement Part Number 8529008. 4-wire receptacle (14-30R...recommended that is equipped with a cord having an equipmentgrounding conductor and a grounding plug. GROUNDING INSTRUCTIONS For a grounded, cord-connected dryer: This dryer must be obtained from: Canadian Standards Association, 178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA. ■■ To supply the...
Installation Instructions
Page 9
... use copper tubing. ■■ Lengths over 20 ft. (6.1 m) should use propane gas, 3/8" propane compatible copper tubing can result in your dryer has been converted to flare adapter fitting C. 1/8" NPT minimum plugged tapping D. 1/2" NPT gas supply line E. Propane Gas Conversion: IMPORTANT: Conversion must...by a qualified technician. In the U.S.A.: An individual manual shut-off valve must be installed within six (6) ft. (1.8 m) of your dryer to propane, have the correct burner for use with propane gas with the National Fuel Gas Code, ANSI Z223.1. If connected to the...
... use copper tubing. ■■ Lengths over 20 ft. (6.1 m) should use propane gas, 3/8" propane compatible copper tubing can result in your dryer has been converted to flare adapter fitting C. 1/8" NPT minimum plugged tapping D. 1/2" NPT gas supply line E. Propane Gas Conversion: IMPORTANT: Conversion must...by a qualified technician. In the U.S.A.: An individual manual shut-off valve must be installed within six (6) ft. (1.8 m) of your dryer to propane, have the correct burner for use with propane gas with the National Fuel Gas Code, ANSI Z223.1. If connected to the...
Installation Instructions
Page 10
... Btu rating shown on the model/serial number plate is mounted on the pedestal model. use TEFLON® tape. ■■ This dryer must be connected to its final location. Leave enough room to avoid kinking. ■■ Use only pipe-joint compound. GAS SUPPLY CONNECTION... REQUIREMENTS ■■ Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting between the flexible gas connector and the dryer gas pipe, as needed to connect the exhaust vent. 10 INSTALL LEVELING LEGS 1. For a garage installation, the gas pipe height must be an ...
... Btu rating shown on the model/serial number plate is mounted on the pedestal model. use TEFLON® tape. ■■ This dryer must be connected to its final location. Leave enough room to avoid kinking. ■■ Use only pipe-joint compound. GAS SUPPLY CONNECTION... REQUIREMENTS ■■ Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting between the flexible gas connector and the dryer gas pipe, as needed to connect the exhaust vent. 10 INSTALL LEVELING LEGS 1. For a garage installation, the gas pipe height must be an ...
Installation Instructions
Page 12
... local codes do not permit the use of 3-wire connections. Connect ground wire 4-wire receptacle (NEMA type 14-30R) 4 prong plug Spade terminals with the dryer cabinet and be in a horizontal position. Tighten screw. Connect neutral ground wire and neutral wire Power supply cord 4-wire receptacle (NEMA Type 14-30R): Go...
... local codes do not permit the use of 3-wire connections. Connect ground wire 4-wire receptacle (NEMA type 14-30R) 4 prong plug Spade terminals with the dryer cabinet and be in a horizontal position. Tighten screw. Connect neutral ground wire and neutral wire Power supply cord 4-wire receptacle (NEMA Type 14-30R): Go...
Installation Instructions
Page 13
...2. Remove center screw Connect remaining wires under outer terminal block screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Now go to neutral wire. Tighten screws. Secure cover with upturned ends Ring terminals 1. Connect remaining wires 3-wire ...terminal block cover into slot of power supply cord under center terminal block screw (B). Connect neutral wire (white or center) (C) of dryer rear panel. Tighten screw. 3. Now go to "Venting Requirements." 3-Wire Power Supply Cord Connection Use where local codes permit connecting ...
...2. Remove center screw Connect remaining wires under outer terminal block screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Now go to neutral wire. Tighten screws. Secure cover with upturned ends Ring terminals 1. Connect remaining wires 3-wire ...terminal block cover into slot of power supply cord under center terminal block screw (B). Connect neutral wire (white or center) (C) of dryer rear panel. Tighten screw. 3. Now go to "Venting Requirements." 3-Wire Power Supply Cord Connection Use where local codes permit connecting ...
Installation Instructions
Page 14
The strain relief should have 5 ft. (1.52 m) of extra length so dryer may be in a horizontal position. Prepare your wiring looks like this: 4-wire direct connection: Go to "4-Wire Direct Wire Connection" on this page. 3-wire direct ...connection: Go to strain relief Direct wire strain relief 1. Direct wire cable must have a tight fit with the dryer cabinet and be moved if needed. Strip insulation back 1" (25 mm). Tighten strain relief screw against the direct wire cable. Reaching inside the terminal block...
The strain relief should have 5 ft. (1.52 m) of extra length so dryer may be in a horizontal position. Prepare your wiring looks like this: 4-wire direct connection: Go to "4-Wire Direct Wire Connection" on this page. 3-wire direct ...connection: Go to strain relief Direct wire strain relief 1. Direct wire cable must have a tight fit with the dryer cabinet and be moved if needed. Strip insulation back 1" (25 mm). Tighten strain relief screw against the direct wire cable. Reaching inside the terminal block...
Installation Instructions
Page 15
... wires under outer terminal block screws (hooks facing right). Shape wire ends into slot of cable. Remove neutral ground wire (E) from end of dryer rear panel. Secure cover with outer covering. Squeeze hooked ends together and tighten screw. 4. Connect neutral ground wire and neutral wire Place hooked ...ends of extra length so dryer may be moved if needed. If using 3-wire cable with ground wire, cut bare wire even with hold-down screw. Squeeze hooked ends ...
... wires under outer terminal block screws (hooks facing right). Shape wire ends into slot of cable. Remove neutral ground wire (E) from end of dryer rear panel. Secure cover with outer covering. Squeeze hooked ends together and tighten screw. 4. Connect neutral ground wire and neutral wire Place hooked ...ends of extra length so dryer may be moved if needed. If using 3-wire cable with ground wire, cut bare wire even with hold-down screw. Squeeze hooked ends ...
Installation Instructions
Page 16
Connect remaining wires Connect neutral ground wire (E) and neutral wire (white or center wire) (C) of dryer rear panel. Tighten screw. 3. Finally, reinsert tab of terminal block cover into slot of power supply cord or cable under the ...." Squeeze hooked end together. Tighten screw. 4. Secure cover with a qualified electrician that this grounding method is acceptable before connecting. 4. Place ends of dryer rear panel. Secure cover with hold -down screw. Connect external ground wire 1. Finally, reinsert tab of terminal block cover into slot of remaining wires under...
Connect remaining wires Connect neutral ground wire (E) and neutral wire (white or center wire) (C) of dryer rear panel. Tighten screw. 3. Finally, reinsert tab of terminal block cover into slot of power supply cord or cable under the ...." Squeeze hooked end together. Tighten screw. 4. Secure cover with a qualified electrician that this grounding method is acceptable before connecting. 4. Place ends of dryer rear panel. Secure cover with hold -down screw. Connect external ground wire 1. Finally, reinsert tab of terminal block cover into slot of remaining wires under...
Installation Instructions
Page 17
... brushing on threads of pipe fittings must use TEFLON® tape. Securely tighten all non-flared male fittings. A. 3/8" flexible gas connector B. 3/8" dryer gas pipe C. 3/8" to 3/8" pipe elbow D. 3/8" pipe-to-flare adapter fitting A combination of all gas connections. Open shut-off valve. Do not use... authorized gas company personnel, and authorized service personnel. Flared male fitting B. If flexible metal tubing is used, be used to connect dryer to do so can result in supply line; Failure to existing gas line. valve is open when handle is shown. Plan pipe ...
... brushing on threads of pipe fittings must use TEFLON® tape. Securely tighten all non-flared male fittings. A. 3/8" flexible gas connector B. 3/8" dryer gas pipe C. 3/8" to 3/8" pipe elbow D. 3/8" pipe-to-flare adapter fitting A combination of all gas connections. Open shut-off valve. Do not use... authorized gas company personnel, and authorized service personnel. Flared male fitting B. If flexible metal tubing is used, be used to connect dryer to do so can result in supply line; Failure to existing gas line. valve is open when handle is shown. Plan pipe ...
Installation Instructions
Page 18
... not use duct tape. 18 Flexible metal vent: (Acceptable only if accessible to clean) ■■ Must be fully extended and supported in final dryer location. ■■ Remove excess to keep rodents and insects from entering the home. ■■ Must be at least 12" (305 mm)... avoid crushing and kinking. WARNING: To reduce the risk of the system and make sure exhaust hood is not plugged with a magnetic latch. Dryer exhaust must not be connected or secured with rigid metal or flexible metal vents. Louvered Hood Acceptable Style: Box Hood Angled Hood Elbows: 45...
... not use duct tape. 18 Flexible metal vent: (Acceptable only if accessible to clean) ■■ Must be fully extended and supported in final dryer location. ■■ Remove excess to keep rodents and insects from entering the home. ■■ Must be at least 12" (305 mm)... avoid crushing and kinking. WARNING: To reduce the risk of the system and make sure exhaust hood is not plugged with a magnetic latch. Dryer exhaust must not be connected or secured with rigid metal or flexible metal vents. Louvered Hood Acceptable Style: Box Hood Angled Hood Elbows: 45...
Installation Instructions
Page 19
... G Special provisions for best drying performance: ■■ Use the following "Vent System Charts" to a noncombustible portion of dryer. ■■ Reduce performance, resulting in longer drying times and increased energy usage. A. Failure to follow these instructions can be... except long vent), or through the bottom. Clamps F. Rigid metal or flexible metal vent G. Vent length necessary to have the dryer converted. Wall D. Exhaust outlet WARNING Fire Hazard Cover unused exhaust holes with a manufacturer's exhaust cover kit. A. Standard Vent System Chart...
... G Special provisions for best drying performance: ■■ Use the following "Vent System Charts" to a noncombustible portion of dryer. ■■ Reduce performance, resulting in longer drying times and increased energy usage. A. Failure to follow these instructions can be... except long vent), or through the bottom. Clamps F. Rigid metal or flexible metal vent G. Vent length necessary to have the dryer converted. Wall D. Exhaust outlet WARNING Fire Hazard Cover unused exhaust holes with a manufacturer's exhaust cover kit. A. Standard Vent System Chart...
Installation Instructions
Page 20
... vent system, refer to exhaust hood with 4" (102 mm) clamp. Avoid 90° turns. Install exhaust hood Install exhaust hood and use caulking compound to dryer location using straightest path possible. Connect vent to seal all joints. Use clamps to exhaust hood Vent must fit over the exhaust hood. Long Vent...
... vent system, refer to exhaust hood with 4" (102 mm) clamp. Avoid 90° turns. Install exhaust hood Install exhaust hood and use caulking compound to dryer location using straightest path possible. Connect vent to seal all joints. Use clamps to exhaust hood Vent must fit over the exhaust hood. Long Vent...
Installation Instructions
Page 21
... washer from inlet hose and replace with additional 2/3 turn . NOTE: Do not overtighten. Screw on coupling by hand until it is seated on faucet. The dryer must be connected to reduce the risk of the 2 ft. (0.6 m) inlet hose. Screw on coupling by hand until it is seated on the hoses for...
... washer from inlet hose and replace with additional 2/3 turn . NOTE: Do not overtighten. Screw on coupling by hand until it is seated on faucet. The dryer must be connected to reduce the risk of the 2 ft. (0.6 m) inlet hose. Screw on coupling by hand until it is seated on the hoses for...