Owners Manual
Page 8
...7. ITEMS EXCLUDED FROM WARRANTY This limited warranty does not cover: 1. Service calls to correct house wiring or plumbing. 2. Costs associated with the removal from accident, alteration, misuse, abuse, fire, flood...damage results from defects in accordance with electrical or plumbing codes, or use of your major appliance, to instruct you on the oven frame behind the broiler door. If ...-2692 Please include a daytime phone number in an inaccessible location or is covered by Maytag. 5. Damage resulting from your major appliance for factory specified parts and repair labor to...
...7. ITEMS EXCLUDED FROM WARRANTY This limited warranty does not cover: 1. Service calls to correct house wiring or plumbing. 2. Costs associated with the removal from accident, alteration, misuse, abuse, fire, flood...damage results from defects in accordance with electrical or plumbing codes, or use of your major appliance, to instruct you on the oven frame behind the broiler door. If ...-2692 Please include a daytime phone number in an inaccessible location or is covered by Maytag. 5. Damage resulting from your major appliance for factory specified parts and repair labor to...
Installation Instructions
Page 2
...wire connectors Parts supplied ■ 0.188 x 2.1" screws - Single Oven A E B D C A. 22¹⁄₄" (56.5 cm) max. Read and follow the instructions provided with bottom of cutout to support a single oven weight of 154 lbs (70 kg) or a double oven weight of the oven. ■ Grounded electrical supply is required. Check existing electrical...width E. 1¹⁄₂" (3.8 cm) min. See "Electrical Requirements" section. ■ Electrical supply junction box should be located in Cabinet A B F D E C A. 24" (61 cm) min. overall height C. 23⁷⁄₈...
...wire connectors Parts supplied ■ 0.188 x 2.1" screws - Single Oven A E B D C A. 22¹⁄₄" (56.5 cm) max. Read and follow the instructions provided with bottom of cutout to support a single oven weight of 154 lbs (70 kg) or a double oven weight of the oven. ■ Grounded electrical supply is required. Check existing electrical...width E. 1¹⁄₂" (3.8 cm) min. See "Electrical Requirements" section. ■ Electrical supply junction box should be located in Cabinet A B F D E C A. 24" (61 cm) min. overall height C. 23⁷⁄₈...
Installation Instructions
Page 3
... or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. cabinet width B. 1¹⁄₂" (3.8 cm) top of upper cabinet door C. 17" (43.2 cm) min. Double or Single Oven A B E C D A. 24"(61 cm) min. Oven front D. This oven must be connected to bottom of cutout to a grounded metal, permanent wiring system. See the following illustration. 3 cutout...
... or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. cabinet width B. 1¹⁄₂" (3.8 cm) top of upper cabinet door C. 17" (43.2 cm) min. Double or Single Oven A B E C D A. 24"(61 cm) min. Oven front D. This oven must be connected to bottom of cutout to a grounded metal, permanent wiring system. See the following illustration. 3 cutout...
Installation Instructions
Page 4
... directly to avoid drilling into the notches on the final location for lifting. 3. Locate existing wiring to the junction box. ■ Do not cut the conduit. Remove the hardware package from the oven. 4. A A Single Oven A. Model/serial number plate Double Oven A. See "Make Electrical Connection" section. ■ Flexible conduit from inside the bag containing literature. 5. Remove...
... directly to avoid drilling into the notches on the final location for lifting. 3. Locate existing wiring to the junction box. ■ Do not cut the conduit. Remove the hardware package from the oven. 4. A A Single Oven A. Model/serial number plate Double Oven A. See "Make Electrical Connection" section. ■ Flexible conduit from inside the bag containing literature. 5. Remove...
Installation Instructions
Page 5
.... Feed the flexible conduit from Home Power Supply 3. For Double Ovens Make Electrical Connection For Single Ovens WARNING WARNING Electrical Shock Hazard Disconnect power before servicing. Use 8 gauge solid copper wire. Electrically ground oven. Use 12 gauge solid copper wire. Electrical Connection Options Chart If your type of electrical connection. ½" (1.3 cm) 5 Remove junction box cover, if it is manufactured with...
.... Feed the flexible conduit from Home Power Supply 3. For Double Ovens Make Electrical Connection For Single Ovens WARNING WARNING Electrical Shock Hazard Disconnect power before servicing. Use 8 gauge solid copper wire. Electrically ground oven. Use 12 gauge solid copper wire. Electrical Connection Options Chart If your type of electrical connection. ½" (1.3 cm) 5 Remove junction box cover, if it is manufactured with...
Installation Instructions
Page 6
... listed or CSA approved conduit connector 1. Connect the 2 red wires (G) together using a UL listed wire connector. 2. A B E F G C H D I . UL listed wire connectors H. Connect the 2 black wires (B) together using a UL listed wire connector. 4. White wires G. Connect the 2 red wires (C) together using a UL listed wire connector. 2. White wires E. Green (or bare) ground wire (from oven) F. 4-wire flexible conduit from home power supply where local codes permit...
... listed or CSA approved conduit connector 1. Connect the 2 red wires (G) together using a UL listed wire connector. 2. A B E F G C H D I . UL listed wire connectors H. Connect the 2 black wires (B) together using a UL listed wire connector. 4. White wires G. Connect the 2 red wires (C) together using a UL listed wire connector. 2. White wires E. Green (or bare) ground wire (from oven) F. 4-wire flexible conduit from home power supply where local codes permit...