Service Manual
Page 15
...;F ) < 1Ω Same shape as Thermal cut off . NC" 1. Hi limit Thermostat (Auto reset) 3. "NC" (1-3) Terminal: "COM" - Lever push (close) Resistance value ∞ 14 Component 1. Outlet Thermostat ( Auto reset) • Check Top Marking: N85 4. 5 COMPONENT TESTING INFORMATION ! ...CAUTION When checking the Component, be replaced Safety Open at 149 ± 9°F (65 ± 5°C) Same shape as Outlet Thermostat. Resistance value ∞ Resistance value < 5Ω Measure resistance of the following terminal 1) Door switch knob: open must • Heater ...
...;F ) < 1Ω Same shape as Thermal cut off . NC" 1. Hi limit Thermostat (Auto reset) 3. "NC" (1-3) Terminal: "COM" - Lever push (close) Resistance value ∞ 14 Component 1. Outlet Thermostat ( Auto reset) • Check Top Marking: N85 4. 5 COMPONENT TESTING INFORMATION ! ...CAUTION When checking the Component, be replaced Safety Open at 149 ± 9°F (65 ± 5°C) Same shape as Outlet Thermostat. Resistance value ∞ Resistance value < 5Ω Measure resistance of the following terminal 1) Door switch knob: open must • Heater ...
Service Manual
Page 17
... If thermal fuse is open must be replaced Resistance value ∞ Continuity < 1Ω • Gas type • Gas funnel 15. Outlet Thermostat (Manual reset) • Check Top Marking: N100 Measure resistance of terminal to terminal Red-White : 300 ± 20 Ω White-Black ...: 300 ± 20 Ω Resistance value ∞ Continuity < 1Ω • Elect type • Gas type 16 Outlet Thermostat (Auto reset) Test Procedure Measure resistance of terminal to terminal Open at 158 ± 9°F (70 ± 5°C) Check result Resistance value ∞...
... If thermal fuse is open must be replaced Resistance value ∞ Continuity < 1Ω • Gas type • Gas funnel 15. Outlet Thermostat (Manual reset) • Check Top Marking: N100 Measure resistance of terminal to terminal Red-White : 300 ± 20 Ω White-Black ...: 300 ± 20 Ω Resistance value ∞ Continuity < 1Ω • Elect type • Gas type 16 Outlet Thermostat (Auto reset) Test Procedure Measure resistance of terminal to terminal Open at 158 ± 9°F (70 ± 5°C) Check result Resistance value ∞...
Service Manual
Page 20
...WHITE DOOR SWITCH OVERLOAD PROTECTOR BLUE ORANGE RED BLUE HEATER 2 1 2 1 MOISTURE THERMISTOR SENSOR RED SAFETY THERMOSTAT OUTER COIL INNER COIL CENTRIFUGAL SWITCH BLOWER WHITE THERMOSTAT RED RED HI - LIMIT THERMOSTAT MOISTURE SENSOR GAS DRYER WIRING DIAGRAM POWER CORD ELECTRONIC CONTROL L1 BLACK N WHITE GN/YL 1 WH1 ... 34 3 1 1 3 123 6 5 4321 8 7 6 5 4 3 2 COM 1 NO 1 2 GRAY NC LAMP YELLOW BROWN BROWN 1 2 3 BELT SWITCH BLOWER THERMOSTAT GRAY BLUE BLUE BLUE RED 23 1212 IGNITER BLUE 21 21 YELLOW 123 DOOR SWITCH MOTOR 2379 OVERLOAD PROTECTOR HI-LIMIT...
...WHITE DOOR SWITCH OVERLOAD PROTECTOR BLUE ORANGE RED BLUE HEATER 2 1 2 1 MOISTURE THERMISTOR SENSOR RED SAFETY THERMOSTAT OUTER COIL INNER COIL CENTRIFUGAL SWITCH BLOWER WHITE THERMOSTAT RED RED HI - LIMIT THERMOSTAT MOISTURE SENSOR GAS DRYER WIRING DIAGRAM POWER CORD ELECTRONIC CONTROL L1 BLACK N WHITE GN/YL 1 WH1 ... 34 3 1 1 3 123 6 5 4321 8 7 6 5 4 3 2 COM 1 NO 1 2 GRAY NC LAMP YELLOW BROWN BROWN 1 2 3 BELT SWITCH BLOWER THERMOSTAT GRAY BLUE BLUE BLUE RED 23 1212 IGNITER BLUE 21 21 YELLOW 123 DOOR SWITCH MOTOR 2379 OVERLOAD PROTECTOR HI-LIMIT...
Service Manual
Page 21
... 1 Display: See page See test 2 Once Motor Motor runs 70 ~ 239 Measured Moisture Value. Activating the Heater manually with the Door open may trip the Thermostat attached to the Heater, therefore do not activate it manually. (Do not press the door switch to the step 4. • Press Start 3 times and then...
... 1 Display: See page See test 2 Once Motor Motor runs 70 ~ 239 Measured Moisture Value. Activating the Heater manually with the Door open may trip the Thermostat attached to the Heater, therefore do not activate it manually. (Do not press the door switch to the step 4. • Press Start 3 times and then...
Service Manual
Page 26
...closed . Measure while door is closed . NO YES • Replace Control. (Relay check) • Check Controller connector. • Replace Outlet • Thermostat. (Refer to 'Component') • Check Idler Assembly. • Drum Belt cuts off • Drum Belt takes off , and do voltage discharge. (...When discharging, contact the metal plug of Outlet Thermostat attached to blower housing? Test 3 Motor test Caution Before measuring resistance, be sure to turn Power off from Motor Pulley. • Replace ...
...closed . Measure while door is closed . NO YES • Replace Control. (Relay check) • Check Controller connector. • Replace Outlet • Thermostat. (Refer to 'Component') • Check Idler Assembly. • Drum Belt cuts off • Drum Belt takes off , and do voltage discharge. (...When discharging, contact the metal plug of Outlet Thermostat attached to blower housing? Test 3 Motor test Caution Before measuring resistance, be sure to turn Power off from Motor Pulley. • Replace ...
Service Manual
Page 29
...22Ω? 3. Check if the value of measured resistance is below 9 ~ 11Ω? NO YES • Replace TH3 (HI-Limit Thermostat). Is resistance between Heater terminal and below 1Ω between terminal NO and at RUN condition. • Check Motor and replace it. ...Drying time takes longer. NO YES • Replace TH2 (Safety Thermostat). Check Harness-linking Connector. 28 Electric Type Caution Before measuring resistance, be sure to turn Power off , measure the resistance. TH3 TH2...
...22Ω? 3. Check if the value of measured resistance is below 9 ~ 11Ω? NO YES • Replace TH3 (HI-Limit Thermostat). Is resistance between Heater terminal and below 1Ω between terminal NO and at RUN condition. • Check Motor and replace it. ...Drying time takes longer. NO YES • Replace TH2 (Safety Thermostat). Check Harness-linking Connector. 28 Electric Type Caution Before measuring resistance, be sure to turn Power off , measure the resistance. TH3 TH2...
Service Manual
Page 30
Trouble Symptom While operating, Heating will not work. YES NO • Check thermostat Hi limit Safety Igniter operates? (after 1 min, Igniter becomes reddish) YES NO • Check Igniter & Frame detect When measuring Valve 2 voltage, Value is more than ...
Trouble Symptom While operating, Heating will not work. YES NO • Check thermostat Hi limit Safety Igniter operates? (after 1 min, Igniter becomes reddish) YES NO • Check Igniter & Frame detect When measuring Valve 2 voltage, Value is more than ...
Service Manual
Page 45
..., read the safety precautions in this manual. ¡Æ Note: S(Safety Parts), AL (Alternative parts) LG MODEL: TD-V10062E, TD-V10060E AL LOC Description Model P/No DLE2512W DLE2514W A500 CABINET ASSEMBLY 3091EL0003A 3091EL0003A K610 MOTOR ...DUCT ASSEMBLY 3044EL002C 3044EL002C 5209EL1001C 5209EL1001C K250 ROLLER ASSEMBLY F110 HEATER ASSEMBLY 4581EL3001A 4581EL3001A 5301EL1001E 5301EL1001E F130 THERMOSTAT ASSEMBLY F140 THERMOSTAT ASSEMBLY 6931EL3003D 6931EL3003D 6931EL3001E 6931EL3001E A600 HARNESS, PWB K100 TUB ASSEMBLY, DRUM 6877EL1007A 6877EL1007B 3045EL1002D 3045EL1002D ...
..., read the safety precautions in this manual. ¡Æ Note: S(Safety Parts), AL (Alternative parts) LG MODEL: TD-V10062E, TD-V10060E AL LOC Description Model P/No DLE2512W DLE2514W A500 CABINET ASSEMBLY 3091EL0003A 3091EL0003A K610 MOTOR ...DUCT ASSEMBLY 3044EL002C 3044EL002C 5209EL1001C 5209EL1001C K250 ROLLER ASSEMBLY F110 HEATER ASSEMBLY 4581EL3001A 4581EL3001A 5301EL1001E 5301EL1001E F130 THERMOSTAT ASSEMBLY F140 THERMOSTAT ASSEMBLY 6931EL3003D 6931EL3003D 6931EL3001E 6931EL3001E A600 HARNESS, PWB K100 TUB ASSEMBLY, DRUM 6877EL1007A 6877EL1007B 3045EL1002D 3045EL1002D ...
Service Manual
Page 46
... read the safety precautions in this manual. ¡Æ Note: S(Safety Parts), AL (Alternative parts) LG MODEL: TD-V10062G,TD-V10060G AL LOC Description Model P/N DLE2522W DLE2524W A500 CABINET ASSEMBLY 3091EL0003B 3091EL0003B A520 BRACKET,... F200 DUCT ASSEMBLY 5209EL1001C 5209EL1001C K250 ROLLER ASSEMBLY 4581EL3001A 4581EL3001A F110 HEATER ASSEMBLY 5301EL1001E 5301EL1001E F130 THERMOSTAT ASSEMBLY 6931EL3003D 6931EL3003D F140 THERMOSTAT ASSEMBLY 6931EL3001E 6931EL3001E A600 HARNESS, PWB 6877EL1008A 6877EL1008A K100 TUB ASSEMBLY, DRUM 3045EL1002D 3045EL1002D K140 SEAL...
... read the safety precautions in this manual. ¡Æ Note: S(Safety Parts), AL (Alternative parts) LG MODEL: TD-V10062G,TD-V10060G AL LOC Description Model P/N DLE2522W DLE2524W A500 CABINET ASSEMBLY 3091EL0003B 3091EL0003B A520 BRACKET,... F200 DUCT ASSEMBLY 5209EL1001C 5209EL1001C K250 ROLLER ASSEMBLY 4581EL3001A 4581EL3001A F110 HEATER ASSEMBLY 5301EL1001E 5301EL1001E F130 THERMOSTAT ASSEMBLY 6931EL3003D 6931EL3003D F140 THERMOSTAT ASSEMBLY 6931EL3001E 6931EL3001E A600 HARNESS, PWB 6877EL1008A 6877EL1008A K100 TUB ASSEMBLY, DRUM 3045EL1002D 3045EL1002D K140 SEAL...