Product Specification
Page 2
... Frequency - Added Section 3.15 - Updated Appendix G - Added Section 3.13.3 Intel® Trusted Execution Technology(Intel® TXT) - Added Processor Stepping Mismatching on Table 2 - Updated Section 3.3.3 - Removed CCC related notices - added BIOS Setup Utility Section; Added Fan Domain Table in Section 4.3.2.2.1 - Added Appendix G Installation Guidelines - Revision History Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS Revision History Date...
... Frequency - Added Section 3.15 - Updated Appendix G - Added Section 3.13.3 Intel® Trusted Execution Technology(Intel® TXT) - Added Processor Stepping Mismatching on Table 2 - Updated Section 3.3.3 - Removed CCC related notices - added BIOS Setup Utility Section; Added Fan Domain Table in Section 4.3.2.2.1 - Added Appendix G Installation Guidelines - Revision History Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS Revision History Date...
Product Specification
Page 6
... 7.1 CMOS Clear and Password Reset Usage Procedure 119 7.1.1 Clearing the CMOS 119 7.1.2 Clearing the Password 119 7.2 Force BMC Update Procedure 120 7.3 BIOS Recovery Jumper 120 8. Design and Environmental Specifications 128 9.1 Intel® Server Boards S5520HC, S5500HCV, and S5520HCT Design Specifications128 9.2 MTBF ...128 9.3 Server Board Power Requirements 130 9.3.1 Processor Power Support 131 9.4 Power Supply Output Requirements...
... 7.1 CMOS Clear and Password Reset Usage Procedure 119 7.1.1 Clearing the CMOS 119 7.1.2 Clearing the Password 119 7.2 Force BMC Update Procedure 120 7.3 BIOS Recovery Jumper 120 8. Design and Environmental Specifications 128 9.1 Intel® Server Boards S5520HC, S5500HCV, and S5520HCT Design Specifications128 9.2 MTBF ...128 9.3 Server Board Power Requirements 130 9.3.1 Processor Power Support 131 9.4 Power Supply Output Requirements...
Product Specification
Page 38
... supports the Intel® Hyper-Threading Technology, the BIOS Setup provides an option to execute code. If the processor supports this feature, the BIOS setup provides an option to enable or disable this feature. Displays "8180: Processor 0x microcode update not found"... successfully. Continues to describe the virtual processors. The BIOS detects the error condition and responds as follows: - Functional Architecture Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS Error Processor Intel® QuickPath Interconnect speeds not identical Processor microcode missing...
... supports the Intel® Hyper-Threading Technology, the BIOS Setup provides an option to execute code. If the processor supports this feature, the BIOS setup provides an option to enable or disable this feature. Displays "8180: Processor 0x microcode update not found"... successfully. Continues to describe the virtual processors. The BIOS detects the error condition and responds as follows: - Functional Architecture Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS Error Processor Intel® QuickPath Interconnect speeds not identical Processor microcode missing...
Product Specification
Page 67
... ACPI methods and then resets the system. 3. When an operating system modifies the TPM state, the BIOS Setup displays the updated TPM state. The BIOS Setup TPM Clear option allows the operator to clear the TPM ownership key and allows the operator to... The Intel® Server Board S5520HCT provides TPM settings through the BIOS setup requires TPM physical presence verification. Performing TPM administrative options through the security screen. You use this screen from the operating system proceeds as follows: 1. Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS ...
... ACPI methods and then resets the system. 3. When an operating system modifies the TPM state, the BIOS Setup displays the updated TPM state. The BIOS Setup TPM Clear option allows the operator to clear the TPM ownership key and allows the operator to... The Intel® Server Board S5520HCT provides TPM settings through the BIOS setup requires TPM physical presence verification. Performing TPM administrative options through the security screen. You use this screen from the operating system proceeds as follows: 1. Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS ...
Product Specification
Page 75
... supports storage and access of communication buses, sensors, and the system BIOS, and server management firmware. Serial-over -LAN protocol (RMCP, RMCP... Messaging support, including command bridging and user/session support. Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS Platform Management 4. Figure 27 provides an illustration of ...: The BMC tracks ACPI state changes provided by the BIOS. Sensor device and sensor scanning/monitoring: The BMC provides IPMI...Chassis device functionality, including power/reset control and BIOS boot flags support. BMC Self-test: The BMC...
... supports storage and access of communication buses, sensors, and the system BIOS, and server management firmware. Serial-over -LAN protocol (RMCP, RMCP... Messaging support, including command bridging and user/session support. Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS Platform Management 4. Figure 27 provides an illustration of ...: The BMC tracks ACPI state changes provided by the BIOS. Sensor device and sensor scanning/monitoring: The BMC provides IPMI...Chassis device functionality, including power/reset control and BIOS boot flags support. BMC Self-test: The BMC...
Product Specification
Page 78
... device appears as a remote device to launch more than two KVM sessions. Platform Management Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS (JRE6) or later to the local USB connection on the BIOS Setup USB screen with or without RMM3 installed. 4.2.2.1 Keyboard and Mouse The keyboard and mouse...set of USB keyboard and mouse for the KVM redirection function of Intel® RMM3, even if no presence of the local devices on the server. You can download the latest Java Runtime Environment (JRE) update: http://java.com/en/download/index.jsp. The default inactivity ...
... device appears as a remote device to launch more than two KVM sessions. Platform Management Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS (JRE6) or later to the local USB connection on the BIOS Setup USB screen with or without RMM3 installed. 4.2.2.1 Keyboard and Mouse The keyboard and mouse...set of USB keyboard and mouse for the KVM redirection function of Intel® RMM3, even if no presence of the local devices on the server. You can download the latest Java Runtime Environment (JRE) update: http://java.com/en/download/index.jsp. The default inactivity ...
Product Specification
Page 82
Platform Management Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS 4.3.1 Memory Open and Closed Loop Thermal Throttling Open...run time. 4.3.2.1 System Configuration Using the FRUSDR Utility The Field Replaceable Unit and Sensor Data Record Update Utility (FRUSDR utility) is used to write platform-specific configuration data to the memory region are ... power consumption and thermal output. During normal system operation, the BMC will retrieve information from the BIOS Setup to memory temperature via thermal sensors integrated on the Serial Presence Detect (SPD) of the ...
Platform Management Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS 4.3.1 Memory Open and Closed Loop Thermal Throttling Open...run time. 4.3.2.1 System Configuration Using the FRUSDR Utility The Field Replaceable Unit and Sensor Data Record Update Utility (FRUSDR utility) is used to write platform-specific configuration data to the memory region are ... power consumption and thermal output. During normal system operation, the BMC will retrieve information from the BIOS Setup to memory temperature via thermal sensors integrated on the Serial Presence Detect (SPD) of the ...
Product Specification
Page 123
Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS Connector/Header Locations and Pin-outs Connector Quantity Reference Designators Connector Type Configuration jumpers 4 J1E6 (CMOS Clear), J1E2 (ME Force Update), J1E4 (Password Clear), J1E5 (BIOS Recovery), J1H1 (BMC Force Jumper Update), HDD Led 1 J1E1 * Empty on Intel® Server Board S5500HCV. Table 47. The following ...+12 Vdc CPU1 7 +12 Vdc DDR3_CPU1 8 +12 Vdc DDR3_CPU1 Color Black Black Black Black Yellow/black Yellow/black Yellow/black Yellow/black Revision 1.8 109 Intel order number E39529-013
Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS Connector/Header Locations and Pin-outs Connector Quantity Reference Designators Connector Type Configuration jumpers 4 J1E6 (CMOS Clear), J1E2 (ME Force Update), J1E4 (Password Clear), J1E5 (BIOS Recovery), J1H1 (BMC Force Jumper Update), HDD Led 1 J1E1 * Empty on Intel® Server Board S5500HCV. Table 47. The following ...+12 Vdc CPU1 7 +12 Vdc DDR3_CPU1 8 +12 Vdc DDR3_CPU1 Color Black Black Black Black Yellow/black Yellow/black Yellow/black Yellow/black Revision 1.8 109 Intel order number E39529-013
Product Specification
Page 132
...Jumpers (J1E6, J1E2, J1E4, J1E5, J1H1) Jumper Name Pins 1-2 J1E6: CMOS Clear 2-3 J1E2: ME Update Force 1-2 2-3 1-2 J1E4: Password Clear 2-3 1-2 J1E5: BIOS Recovery 2-3 J1H1: Force BMC 1-2 Update 2-3 System Results These pins should not be connected for normal system operation. (Default) If pins 2-3 are ... power unplugged, the CMOS settings clear in 5-10 seconds after power on. ME Firmware Force Update Mode - The system only boots from EFI-bootable recovery media with pins 2-3 connected. Jumper Blocks Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS 7.
...Jumpers (J1E6, J1E2, J1E4, J1E5, J1H1) Jumper Name Pins 1-2 J1E6: CMOS Clear 2-3 J1E2: ME Update Force 1-2 2-3 1-2 J1E4: Password Clear 2-3 1-2 J1E5: BIOS Recovery 2-3 J1H1: Force BMC 1-2 Update 2-3 System Results These pins should not be connected for normal system operation. (Default) If pins 2-3 are ... power unplugged, the CMOS settings clear in 5-10 seconds after power on. ME Firmware Force Update Mode - The system only boots from EFI-bootable recovery media with pins 2-3 connected. Jumper Blocks Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS 7.
Product Specification
Page 134
... pins 2 and 3) to load safely onto the flash device. After successful completion of the BIOS recovery, the "BIOS has been updated successfully" message displays. 120 Revision 1.8 Intel order number E39529-013 Move the jumper (J1H1) from the default operating position (covering pins ...cord and power up the server. Jumper Blocks Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS 7.2 Force BMC Update Procedure When performing a standard BMC firmware update procedure, the update utility places the BMC into the proper update state. Close the server chassis. 5. Power...
... pins 2 and 3) to load safely onto the flash device. After successful completion of the BIOS recovery, the "BIOS has been updated successfully" message displays. 120 Revision 1.8 Intel order number E39529-013 Move the jumper (J1H1) from the default operating position (covering pins ...cord and power up the server. Jumper Blocks Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS 7.2 Force BMC Update Procedure When performing a standard BMC firmware update procedure, the update utility places the BMC into the proper update state. Close the server chassis. 5. Power...
Product Specification
Page 159
...code) provides the PCI device bus number, device number, and function number with the Force BMC Update jumper (J1H1) set to the "enabled" position (pins 2-3). Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS Appendix A: Integration and Usage Tips Appendix A: Integration and Usage Tips • Prior to ... the back edge of the server board, there are supported on each memory channel. • For the best performance, you must set the BIOS Recovery jumper (J1E5) to its default position (pins 1-2). • Locate the device that generates System Event Log (SEL) PCI device event:...
...code) provides the PCI device bus number, device number, and function number with the Force BMC Update jumper (J1H1) set to the "enabled" position (pins 2-3). Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS Appendix A: Integration and Usage Tips Appendix A: Integration and Usage Tips • Prior to ... the back edge of the server board, there are supported on each memory channel. • For the best performance, you must set the BIOS Recovery jumper (J1E5) to its default position (pins 1-2). • Locate the device that generates System Event Log (SEL) PCI device event:...
Product Specification
Page 178
...media device Boot Device Selection 0xDy Trying boot selection y (where y = 0 to complete crisis recovery 164 Revision 1.8 Intel order number E39529-013 Appendix E: POST Code Diagnostic LED Decoder Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS Progress Code 0xB8 0xB9 0xBA 0xBC Progress Code Definition Resetting the removable media device Disabling the removable... 0xE6 Started connecting drivers DXE Drivers (not accompanied by a beep code) 0xE7 Waiting for user input 0xE8 Checking password 0xE9 Entering the BIOS Setup 0xEA Flash Update 0xEE Calling Int 19.
...media device Boot Device Selection 0xDy Trying boot selection y (where y = 0 to complete crisis recovery 164 Revision 1.8 Intel order number E39529-013 Appendix E: POST Code Diagnostic LED Decoder Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS Progress Code 0xB8 0xB9 0xBA 0xBC Progress Code Definition Resetting the removable media device Disabling the removable... 0xE6 Started connecting drivers DXE Drivers (not accompanied by a beep code) 0xE7 Waiting for user input 0xE8 Checking password 0xE9 Entering the BIOS Setup 0xEA Flash Update 0xEE Calling Int 19.