Instruction Manual
Page 20
... CONTROL JACK [REMOTE] (p. 142) ➥ Designed for use a cigarette lighter socket as a TNC for data communications, a linear amplifier or an automatic antenna selector/tuner, etc. • See page at right for ...socket wiring information. y TUNER CONTROL SOCKET [TUNER] (p. 20) Accepts the control cable from an optional AH-4 hf/50 mhz automatic antenna tuner. i EXTERNAL SPEAKER JACK [EXT SP] (p.... !1 ANTENNA CONNECTOR [ANT1], [ANT2] (p. 17) Accepts a 50 Ω antenna with another Icom CI-V transceiver or receiver. DC 13.8V !2 !1 u RTTY JACK [RTTY] (p. 23) Connects...
... CONTROL JACK [REMOTE] (p. 142) ➥ Designed for use a cigarette lighter socket as a TNC for data communications, a linear amplifier or an automatic antenna selector/tuner, etc. • See page at right for ...socket wiring information. y TUNER CONTROL SOCKET [TUNER] (p. 20) Accepts the control cable from an optional AH-4 hf/50 mhz automatic antenna tuner. i EXTERNAL SPEAKER JACK [EXT SP] (p.... !1 ANTENNA CONNECTOR [ANT1], [ANT2] (p. 17) Accepts a 50 Ω antenna with another Icom CI-V transceiver or receiver. DC 13.8V !2 !1 u RTTY JACK [RTTY] (p. 23) Connects...
Instruction Manual
Page 21
... transceiver receives a signal which opens the squelch. FSKK Controls RTTY keying MOD Modulator input. AF Fixed level, regardless of the 11 supplied cable. 12 ALC ALC voltage input. "High" level "Low" level Output current Input impedance Input level : Max. 1 A : More ...SQLS Squelch output. When this pin goes low, Input voltage (Low) Current flow : -0.5 V to activate the transmitter. 1 PANEL DESCRIPTION D DATA socket DATA PIN No. NAME DESCRIPTION SPECIFICATIONS 1 8 V Regulated 8 V output. AF detector output. Grounded when squelch opens. only) The transceiver outputs ...
... transceiver receives a signal which opens the squelch. FSKK Controls RTTY keying MOD Modulator input. AF Fixed level, regardless of the 11 supplied cable. 12 ALC ALC voltage input. "High" level "Low" level Output current Input impedance Input level : Max. 1 A : More ...SQLS Squelch output. When this pin goes low, Input voltage (Low) Current flow : -0.5 V to activate the transmitter. 1 PANEL DESCRIPTION D DATA socket DATA PIN No. NAME DESCRIPTION SPECIFICATIONS 1 8 V Regulated 8 V output. AF detector output. Grounded when squelch opens. only) The transceiver outputs ...
Instruction Manual
Page 33
.... Colors refer to the wires in u144/430 MHz: purple the supplied ACC cable. SQL RX AUDIO PTT RS-232C 2 TNC or PC interface for the software PC D When connecting to [DATA] socket DATA IN q PTTP e t AF OUT w GND r DATA OUT y SQL*1 [DATA] (Rear panel) TX AUDIO GND *1Connect SQL line when required. 2 INSTALLATION AND...
.... Colors refer to the wires in u144/430 MHz: purple the supplied ACC cable. SQL RX AUDIO PTT RS-232C 2 TNC or PC interface for the software PC D When connecting to [DATA] socket DATA IN q PTTP e t AF OUT w GND r DATA OUT y SQL*1 [DATA] (Rear panel) TX AUDIO GND *1Connect SQL line when required. 2 INSTALLATION AND...
Instruction Manual
Page 146
... Memory). 14 MAINTENANCE ■ Fuse replacement If a fuse blows or the transceiver stops functioning, try to all units in the IC-7000, except for transceiver protection. • DC power cable fuses ATC20 30 A • Circuitry fuse ATC20 5 A CIRCUITRY FUSE REPLACEMENT The 13.8 V DC from the transceiver when changing...9632; Cleaning If the transceiver becomes dusty or dirty, wipe it , and replace the damaged fuse with a dry, soft cloth. All data you set mode contents, etc. are stored in the FRONT unit. This fuse is applied to find the source of strong chemical solvents ...
... Memory). 14 MAINTENANCE ■ Fuse replacement If a fuse blows or the transceiver stops functioning, try to all units in the IC-7000, except for transceiver protection. • DC power cable fuses ATC20 30 A • Circuitry fuse ATC20 5 A CIRCUITRY FUSE REPLACEMENT The 13.8 V DC from the transceiver when changing...9632; Cleaning If the transceiver becomes dusty or dirty, wipe it , and replace the damaged fuse with a dry, soft cloth. All data you set mode contents, etc. are stored in the FRONT unit. This fuse is applied to find the source of strong chemical solvents ...
Instruction Manual
Page 151
...Programmed/memory scan start 02 Programmed scan start 22 Memory scan start 23 Select memory scan start 16 17 142 The Icom Communication interface-V (CI-V) controls the following data formats. Memory clear - 17 CONTROL COMMAND ■ Remote jack (CI-V) information D CI-V connection example The ... 0107 Select the call channel (C1=0106, C2=0107) A0 Set the bank number (1=A, 2=B, 3=C, 4=D, 5=E) - IC-7000 mini-plug cable CONTROLLER TO IC-7000 FE FE 70 E0 Cn Sc Data area FD OK MESSAGE TO CONTROLLER FE FE 70 E0 FB FD End of message code (fixed) OK code (fixed...
...Programmed/memory scan start 02 Programmed scan start 22 Memory scan start 23 Select memory scan start 16 17 142 The Icom Communication interface-V (CI-V) controls the following data formats. Memory clear - 17 CONTROL COMMAND ■ Remote jack (CI-V) information D CI-V connection example The ... 0107 Select the call channel (C1=0106, C2=0107) A0 Set the bank number (1=A, 2=B, 3=C, 4=D, 5=E) - IC-7000 mini-plug cable CONTROLLER TO IC-7000 FE FE 70 E0 Cn Sc Data area FD OK MESSAGE TO CONTROLLER FE FE 70 E0 FB FD End of message code (fixed) OK code (fixed...