Owner's Manual
Page 3
ENGLISH Table of contents About your new thermostat Thermostat features 2 Setup at a glance 3 Quick reference to controls 4 Quick reference to display 5 Programming & Operation Fan setting (auto/on 6 System setting (heat/cool/auto 7 Auto-changeover (heat/cool 8 ...
ENGLISH Table of contents About your new thermostat Thermostat features 2 Setup at a glance 3 Quick reference to controls 4 Quick reference to display 5 Programming & Operation Fan setting (auto/on 6 System setting (heat/cool/auto 7 Auto-changeover (heat/cool 8 ...
Installation Guide
Page 4
...must come from cooling transformer. [5] In Installer Setup, set system type to Heat Only. [6] In Installer Setup, set system type to 2Heat/2Cool Conventional. 69-1922EFS-01 [9] In Installer Setup, set system type to 2Heat/2Cool Heat Pump. [10] In Installer Setup, set system type to 2Heat/1Cool Heat ... Heat relay (stage 2) Y2 Compressor contactor (stage 2) G Fan relay See [notes] below NOTES Wire specifications: Use 18- Heat. Connect to Honeywell zoning panels to switch the panel to Emergency Heat. [12] Install field jumper between Aux and E if there is set system type to 3Heat/2Cool...
...must come from cooling transformer. [5] In Installer Setup, set system type to Heat Only. [6] In Installer Setup, set system type to 2Heat/2Cool Conventional. 69-1922EFS-01 [9] In Installer Setup, set system type to 2Heat/2Cool Heat Pump. [10] In Installer Setup, set system type to 2Heat/1Cool Heat ... Heat relay (stage 2) Y2 Compressor contactor (stage 2) G Fan relay See [notes] below NOTES Wire specifications: Use 18- Heat. Connect to Honeywell zoning panels to switch the panel to Emergency Heat. [12] Install field jumper between Aux and E if there is set system type to 3Heat/2Cool...
Installation Guide
Page 6
Setup function Settings & options (factory default in heating) 3 Fan control (heating) 0 Gas or oil furnace - heat) 6 2 heat/2 cool conventional 7 2 heat/1 cool conventional 8 1 heat/2 cool conventional 9 2 heat/2 ... conventional 1 1 heat/1 cool heat pump (no aux. heat) - Press DONE to change settings. TH5320U only 10 3 heat/2 cool heat pump (with aux. Installation Guide Installer setup Follow the procedure below apply only to TH5320U/TH5220D or as desired. Function number Setting 10 Done Next To begin, press and hold the s and...
Setup function Settings & options (factory default in heating) 3 Fan control (heating) 0 Gas or oil furnace - heat) 6 2 heat/2 cool conventional 7 2 heat/1 cool conventional 8 1 heat/2 cool conventional 9 2 heat/2 ... conventional 1 1 heat/1 cool heat pump (no aux. heat) - Press DONE to change settings. TH5320U only 10 3 heat/2 cool heat pump (with aux. Installation Guide Installer setup Follow the procedure below apply only to TH5320U/TH5220D or as desired. Function number Setting 10 Done Next To begin, press and hold the s and...
Installation Guide
Page 7
... Shaded areas below apply only to TH5320U/TH5220D or as otherwise noted. 10 Heating system 0 Heat and fan turn system on if Setup Function 1 is set to 1, 5, 9 or 10 OR Setup Function 3 is 90 °F (32 °C) [Other options: 40 °F to 89 °F (4.5 °C to next test. ...off 1 Heat and fan turn off 1 Fan turns on (auxiliary heat) - cool temperature setting is bypassed during testing. FocusPRO® TH5000 Series Installer setup Setup function Settings & options (factory default in bold) Shaded areas below apply only to turn off. 1 Stage 1 heat turns on -
... Shaded areas below apply only to TH5320U/TH5220D or as otherwise noted. 10 Heating system 0 Heat and fan turn system on if Setup Function 1 is set to 1, 5, 9 or 10 OR Setup Function 3 is 90 °F (32 °C) [Other options: 40 °F to 89 °F (4.5 °C to next test. ...off 1 Heat and fan turn off 1 Fan turns on (auxiliary heat) - cool temperature setting is bypassed during testing. FocusPRO® TH5000 Series Installer setup Setup function Settings & options (factory default in bold) Shaded areas below apply only to turn off. 1 Stage 1 heat turns on -
Installation Guide
Page 8
...A 100 mA DC 0.02-0.5 A 0.02-1.0 A 0.02-1.0 A 0.02-0.5 A 0.02-0.5 A 0.02-1.0 A 0.02-0.5 A Automation and Control Solutions Honeywell International Inc. The thermostat will wait to activate the auxiliary heat depending on heat pump performance, load conditions and how many degrees the temperature setting... is calling for the heat pump. Registered Trademark. © 2009 Honeywell International Inc. 69-1922EFS-01 M.S. 05-09 Installation Guide Special function Auxiliary heat control (Setup Function 26): • Comfort Setting: The thermostat will prioritize comfort over economy...
...A 100 mA DC 0.02-0.5 A 0.02-1.0 A 0.02-1.0 A 0.02-0.5 A 0.02-0.5 A 0.02-1.0 A 0.02-0.5 A Automation and Control Solutions Honeywell International Inc. The thermostat will wait to activate the auxiliary heat depending on heat pump performance, load conditions and how many degrees the temperature setting... is calling for the heat pump. Registered Trademark. © 2009 Honeywell International Inc. 69-1922EFS-01 M.S. 05-09 Installation Guide Special function Auxiliary heat control (Setup Function 26): • Comfort Setting: The thermostat will prioritize comfort over economy...