Owner's Manual
Page 1
Ultraviolet System OWNER'S GUIDE Contents How Your Ultraviolet Air Treatment System or Surface Treatment System Works 2 Be Sure to Read Warnings and Cautions Before Installing or Using Your UV System 3 How to Install Your Ultraviolet System ...4 How You Can Check Your Ultraviolet System ...7 How You Can Maintain Your UV System ...7 69-1859EFS-01
Ultraviolet System OWNER'S GUIDE Contents How Your Ultraviolet Air Treatment System or Surface Treatment System Works 2 Be Sure to Read Warnings and Cautions Before Installing or Using Your UV System 3 How to Install Your Ultraviolet System ...4 How You Can Check Your Ultraviolet System ...7 How You Can Maintain Your UV System ...7 69-1859EFS-01
Owner's Manual
Page 2
....eT NVl!'ienoWuscitiAlaflselRlzapNtoliiIorNuenrGeela/tAt bplVaieeEamnRuacTnionISumteeSpnEeraetMnnlecEdseNr.eT 69-1859EFS-01 Fig. 2. Typical surface treatment installations. 2 M22860 HOW YOUR ULTRAVIOLET AIR TREATMENT SYSTEM OR SURFACE TREATMENT SYSTEM WORKS Depending on installation, your system fan operates. Individual results depend on careful installation and maintenance and on the actual amount of time your Ultraviolet System can operate as an Air Treatment System or as mold that may grow on careful installation and maintenance. See Fig. 1.
....eT NVl!'ienoWuscitiAlaflselRlzapNtoliiIorNuenrGeela/tAt bplVaieeEamnRuacTnionISumteeSpnEeraetMnnlecEdseNr.eT 69-1859EFS-01 Fig. 2. Typical surface treatment installations. 2 M22860 HOW YOUR ULTRAVIOLET AIR TREATMENT SYSTEM OR SURFACE TREATMENT SYSTEM WORKS Depending on installation, your system fan operates. Individual results depend on careful installation and maintenance and on the actual amount of time your Ultraviolet System can operate as an Air Treatment System or as mold that may grow on careful installation and maintenance. See Fig. 1.
Owner's Manual
Page 3
... components with a high-efficiency air filtration system like an electronic air cleaner. Do not open housing; Be careful when inserting bulb(s) into a plastic bag and dispose of properly. Broken Bulb Cleanup. Ultraviolet light can cause color shift or structural degradation of vision. Do not attempt to ultraviolet light. Power supply can cause electrical shock. Dispose of properly. Select mounting location that allows ultraviolet light to open base unit or lamp...
... components with a high-efficiency air filtration system like an electronic air cleaner. Do not open housing; Be careful when inserting bulb(s) into a plastic bag and dispose of properly. Broken Bulb Cleanup. Ultraviolet light can cause color shift or structural degradation of vision. Do not attempt to ultraviolet light. Power supply can cause electrical shock. Dispose of properly. Select mounting location that allows ultraviolet light to open base unit or lamp...
Owner's Manual
Page 4
... of the unit to allow for regular inspection and cleaning. 3. See Fig. 3. 5. After installation is readily accessible for ultraviolet bulb installation and removal. 8. bulb hole in these instructions carefully. The UV Air Treatment System requires an easily-acces- The duct mounting location must be a minimum of the HVAC system. The space adjacent to the mounting location must be large enough to plug in...
... of the unit to allow for regular inspection and cleaning. 3. See Fig. 3. 5. After installation is readily accessible for ultraviolet bulb installation and removal. 8. bulb hole in these instructions carefully. The UV Air Treatment System requires an easily-acces- The duct mounting location must be a minimum of the HVAC system. The space adjacent to the mounting location must be large enough to plug in...
Owner's Manual
Page 5
.... (3 MM) PILOT HOLES FOR MOUNTING SCREWS M18991 Fig. 4. drill to allow bulb insertion. 7. Install the unit on the duct. Use a 3/32 in . Ultraviolet System template. 4. Be sure the duct surface is sealed. 5 69-1859EFS-01 Position the entire base unit on to the duct using the two no.10, 2 in . Phillips head sheet metal mounting screws provided. 8.
.... (3 MM) PILOT HOLES FOR MOUNTING SCREWS M18991 Fig. 4. drill to allow bulb insertion. 7. Install the unit on the duct. Use a 3/32 in . Ultraviolet System template. 4. Be sure the duct surface is sealed. 5 69-1859EFS-01 Position the entire base unit on to the duct using the two no.10, 2 in . Phillips head sheet metal mounting screws provided. 8.
Owner's Manual
Page 6
...wipe fingerprints from glass. 11. Reconnect the power to the HVAC equipment (selected in the air treatment system packing box. See Fig. 10. 69-1859EFS-01 6 ULTRAVIOLET SYSTEM CENTER OF 2 HOLE IFNO. (R51LAMMMP) ...lightly pushing in on the adjacent HVAC equipment for the HVAC maintenance label included in step 16) such as the furnace access door, air cleaner or humidifier. Adhere the HVAC maintenance safety label to the HVAC system. 16. Use cloth to wipe fingerprints from the glass. Plug the cord into the base unit with the raised button on the unit...
...wipe fingerprints from glass. 11. Reconnect the power to the HVAC equipment (selected in the air treatment system packing box. See Fig. 10. 69-1859EFS-01 6 ULTRAVIOLET SYSTEM CENTER OF 2 HOLE IFNO. (R51LAMMMP) ...lightly pushing in on the adjacent HVAC equipment for the HVAC maintenance label included in step 16) such as the furnace access door, air cleaner or humidifier. Adhere the HVAC maintenance safety label to the HVAC system. 16. Use cloth to wipe fingerprints from the glass. Plug the cord into the base unit with the raised button on the unit...
Owner's Manual
Page 7
... base is operating. See Fig. 11. HOW YOU CAN MAINTAIN YOUR UV SYSTEM You should regularly clean your UV System to your air treatment or surface treatment system. Replace the ultraviolet bulb once a year. Disconnect the power to maintain peak effectiveness of your heating and cooling system. 2. Rotate your regular cleaning schedule. Lamp light indicator. Use the UV Bulb Cleaning Reminder Schedule, Fig. 12, to help establish and...
... base is operating. See Fig. 11. HOW YOU CAN MAINTAIN YOUR UV SYSTEM You should regularly clean your UV System to your air treatment or surface treatment system. Replace the ultraviolet bulb once a year. Disconnect the power to maintain peak effectiveness of your heating and cooling system. 2. Rotate your regular cleaning schedule. Lamp light indicator. Use the UV Bulb Cleaning Reminder Schedule, Fig. 12, to help establish and...
Owner's Manual
Page 8
See Fig. 14. Remove lamp bulb. 4. M13516A Fig. 13. If you touch the lamp glass with soft cloth. M22844 8 Clean glass with your hands, be sure to clean the area of any oils left from bare hands. Holding the lamp handle, wipe the lamp glass using a soft cloth dampened with glass cleaner. M22842 69-1859EFS-01 Fig. 14. ULTRAVIOLET SYSTEM UV BULB CLEANING REMINDER SCHEDULE INSTALLATION DATE: (month) , (year) YEAR J F M A M J J A S O N D Fig. 12. UV bulb cleaning reminder schedule.
See Fig. 14. Remove lamp bulb. 4. M13516A Fig. 13. If you touch the lamp glass with soft cloth. M22844 8 Clean glass with your hands, be sure to clean the area of any oils left from bare hands. Holding the lamp handle, wipe the lamp glass using a soft cloth dampened with glass cleaner. M22842 69-1859EFS-01 Fig. 14. ULTRAVIOLET SYSTEM UV BULB CLEANING REMINDER SCHEDULE INSTALLATION DATE: (month) , (year) YEAR J F M A M J J A S O N D Fig. 12. UV bulb cleaning reminder schedule.
Owner's Manual
Page 9
.... Reconnect power to your heating and cooling system. Never look directly at your bulb while it snaps into the base with your ultraviolet bulbs are operating by align- Disconnect lamp glass from your UV System. 10. See Fig. 19. If you touch the lamp glass with the lamp light indicator at least 15 minutes. 4. LAMP LIGHT INDICATOR BASE ULTRAVIOLET SYSTEM M22846 Fig...
.... Reconnect power to your heating and cooling system. Never look directly at your bulb while it snaps into the base with your ultraviolet bulbs are operating by align- Disconnect lamp glass from your UV System. 10. See Fig. 19. If you touch the lamp glass with the lamp light indicator at least 15 minutes. 4. LAMP LIGHT INDICATOR BASE ULTRAVIOLET SYSTEM M22846 Fig...
Owner's Manual
Page 10
... fully into the base with the raised button on the lamp handle. Reconnect power to your UV System. 11. Never look directly at the eleven o'clock position. See Fig 16. 9. Continue pushing and gently rotating counterclockwise until it is operating by viewing only through the lamp light indicator on the unit cover. ULTRAVIOLET SYSTEM 8. Insert the bulb into the base...
... fully into the base with the raised button on the lamp handle. Reconnect power to your UV System. 11. Never look directly at the eleven o'clock position. See Fig 16. 9. Continue pushing and gently rotating counterclockwise until it is operating by viewing only through the lamp light indicator on the unit cover. ULTRAVIOLET SYSTEM 8. Insert the bulb into the base...
Owner's Manual
Page 11
... apply to you purchased it. ULTRAVIOLET SYSTEM Limited Warranty Honeywell warrants this product, excluding bulbs, to be to repair or replace the product within a reasonable period of time. This warranty shall not apply if it is defective or malfunctions, Honeywell shall repair or replace it , with a bill of sale or other rights which you . In Canada, write Honeywell Limited/Honeywell Limitée, 35 Dynamic Dr...
... apply to you purchased it. ULTRAVIOLET SYSTEM Limited Warranty Honeywell warrants this product, excluding bulbs, to be to repair or replace the product within a reasonable period of time. This warranty shall not apply if it is defective or malfunctions, Honeywell shall repair or replace it , with a bill of sale or other rights which you . In Canada, write Honeywell Limited/Honeywell Limitée, 35 Dynamic Dr...
Owner's Manual
Page 12
Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Toronto, Ontario M1V 4Z9 customer.honeywell.com ® U.S. Registered Trademark © 2007 Honeywell International Inc. 69-1859EFS-01 M.S. ULTRAVIOLET SYSTEM M18621B Automation and Control Solutions Honeywell International Inc. Rev. 07-07
Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Toronto, Ontario M1V 4Z9 customer.honeywell.com ® U.S. Registered Trademark © 2007 Honeywell International Inc. 69-1859EFS-01 M.S. ULTRAVIOLET SYSTEM M18621B Automation and Control Solutions Honeywell International Inc. Rev. 07-07