Owners Guide
Page 5
VisionPRO IAQ (YTH9421C1010) • Water line T-fitting • Manual shut-off valve • Remote hose P-trap • Remote mount duct board adapter kit (32005530-001) • Differential pressure switch (50027910-001) * Warranty requires in... kit (50024917-001) - 20-foot hose and nozzle kit (50024917-002) • Humidity Controls - copper or plastic water line • 1/2-in . TrueSTEAM Humidification System What you will need to install TrueSTEAM Tools/Hardware needed: • Wire stripper/cutter • Drill or duct-cutting tool • 1-3/4-in . hole saw • 1/8-in.
VisionPRO IAQ (YTH9421C1010) • Water line T-fitting • Manual shut-off valve • Remote hose P-trap • Remote mount duct board adapter kit (32005530-001) • Differential pressure switch (50027910-001) * Warranty requires in... kit (50024917-001) - 20-foot hose and nozzle kit (50024917-002) • Humidity Controls - copper or plastic water line • 1/2-in . TrueSTEAM Humidification System What you will need to install TrueSTEAM Tools/Hardware needed: • Wire stripper/cutter • Drill or duct-cutting tool • 1-3/4-in . hole saw • 1/8-in.
Owners Guide
Page 15
... 1/4-in . C Connect 1/2-in . D Shut off the water supply. Ensure drain or condensate pump is operational. 13 69-2036EFS-07 TrueSTEAM Humidification System Plumbing 10 A Insert 1/4-in . Secure 1/4-in . copper or plastic Enlarged view C D Continuous downslope Draining water may be.... See instructions provided with hose clamp. T-fitting Manual shutoff valve (sold separately) Saddle valve (provided) Piercing pin To humidifier M24852 To humidifier Water supply line Check all water line connections to ensure no leaks once TrueSTEAM is rated for a tight fit. Apply modest...
... 1/4-in . C Connect 1/2-in . D Shut off the water supply. Ensure drain or condensate pump is operational. 13 69-2036EFS-07 TrueSTEAM Humidification System Plumbing 10 A Insert 1/4-in . Secure 1/4-in . copper or plastic Enlarged view C D Continuous downslope Draining water may be.... See instructions provided with hose clamp. T-fitting Manual shutoff valve (sold separately) Saddle valve (provided) Piercing pin To humidifier M24852 To humidifier Water supply line Check all water line connections to ensure no leaks once TrueSTEAM is rated for a tight fit. Apply modest...
Owners Guide
Page 17
... using a mechanical humidistat Follow this diagram if using VisionPRO IAQTM for manual such as H8908ASPST or other. operation. TrueSTEAM Humidification System Wiring 12 Wire the TrueSTEAM according to the diagram that applies to wire TrueIAQ for independent fan ... 1 RELAY HEAT 2 RELAY HEAT 3 RELAY COOL 1 RELAY COOL 2 RELAY G FAN RELAY M24758 69-2036EFS-07 VISIONPRO IAQ A RECOMMENDED AIR FLOW SWITCH (AFS) TrueSTEAM - TrueSTEAM will independently activate furnace fan (humidity on demand). HVAC R CWY G HUM HUM MECHANICAL HUMIDISTAT RECOMMENDED AIR FLOW SWITCH (AFS...
... using a mechanical humidistat Follow this diagram if using VisionPRO IAQTM for manual such as H8908ASPST or other. operation. TrueSTEAM Humidification System Wiring 12 Wire the TrueSTEAM according to the diagram that applies to wire TrueIAQ for independent fan ... 1 RELAY HEAT 2 RELAY HEAT 3 RELAY COOL 1 RELAY COOL 2 RELAY G FAN RELAY M24758 69-2036EFS-07 VISIONPRO IAQ A RECOMMENDED AIR FLOW SWITCH (AFS) TrueSTEAM - TrueSTEAM will independently activate furnace fan (humidity on demand). HVAC R CWY G HUM HUM MECHANICAL HUMIDISTAT RECOMMENDED AIR FLOW SWITCH (AFS...
Owners Guide
Page 20
...DIP 1 DIP 4 OFF, DIP 5 ON: If TrueSTEAM determines that no airflow* ON is time to manually clean the OFF water tank. Details below. it is time to manually clean the OFF water tank. DIP 6 DIP 5 DIP 4 DIP 3 DIP 2 DIP 1 20 hrs of humidify- 48 hrs before the Press auto-flushes debris until... next call for details. ON DIP 4 ON, DIP 5 either setting: TrueSTEAM will shut down OFF steam output and...
...DIP 1 DIP 4 OFF, DIP 5 ON: If TrueSTEAM determines that no airflow* ON is time to manually clean the OFF water tank. Details below. it is time to manually clean the OFF water tank. DIP 6 DIP 5 DIP 4 DIP 3 DIP 2 DIP 1 20 hrs of humidify- 48 hrs before the Press auto-flushes debris until... next call for details. ON DIP 4 ON, DIP 5 either setting: TrueSTEAM will shut down OFF steam output and...
Owners Guide
Page 24
... auto flushing, cold water will enter the tank to lower water temperature below 140ºF (60ºC) before draining. • During manual flush (performed by pressing the EMPTY button) initial water temperature may be used in accordance with water in . Fan: 1.5A full load...Requirements Underwriters Laboratories: UL998, File no . Installation Guide Specifications Capacity: HM512: 12 gallons per day (gpd) (45 liters per day [lpd]) HM509: 9 gpd (34 lpd) HM506: 6 gpd (23 lpd) Humidified Area: House Air Changes HM512 HM509 HM506 Description Per Hour Loose Two 2000 ft2 1300 ft2 1000 ...
... auto flushing, cold water will enter the tank to lower water temperature below 140ºF (60ºC) before draining. • During manual flush (performed by pressing the EMPTY button) initial water temperature may be used in accordance with water in . Fan: 1.5A full load...Requirements Underwriters Laboratories: UL998, File no . Installation Guide Specifications Capacity: HM512: 12 gallons per day (gpd) (45 liters per day [lpd]) HM509: 9 gpd (34 lpd) HM506: 6 gpd (23 lpd) Humidified Area: House Air Changes HM512 HM509 HM506 Description Per Hour Loose Two 2000 ft2 1300 ft2 1000 ...
Owners Guide
Page 25
... Do not attempt to remove the humidifier from the mounting bracket during operation, or when the humidifier's water tank when full of operational time (heating element active). • During auto flushing, cold water will drain immediately. TrueSTEAM Humidification System Cleaning and Seasonal or ...(60°C) before draining. • During manual flush (performed by pressing the EMPTY button) initial water temperature may be above 140°F (60°C). Drain Operation • Auto flushing is removed. To clean the TrueSTEAM: 1. EMPTY M24774 Wait CLEAN TANK (BLINKING ...
... Do not attempt to remove the humidifier from the mounting bracket during operation, or when the humidifier's water tank when full of operational time (heating element active). • During auto flushing, cold water will drain immediately. TrueSTEAM Humidification System Cleaning and Seasonal or ...(60°C) before draining. • During manual flush (performed by pressing the EMPTY button) initial water temperature may be above 140°F (60°C). Drain Operation • Auto flushing is removed. To clean the TrueSTEAM: 1. EMPTY M24774 Wait CLEAN TANK (BLINKING ...
Owners Guide
Page 26
... at tank's bottom is also dishwasher-safe. Use tap water to the "Unlock" position. 3. Installation Guide Cleaning and Seasonal or Vacation Maintenance 2. Turn the manual shut-off humidifier with tank. 5. For a more thorough cleaning, soak tank in warm, soapy water, then rinse clean. Tank is removable. Sediment screen M24778 6. Scouring pads suitable...
... at tank's bottom is also dishwasher-safe. Use tap water to the "Unlock" position. 3. Installation Guide Cleaning and Seasonal or Vacation Maintenance 2. Turn the manual shut-off humidifier with tank. 5. For a more thorough cleaning, soak tank in warm, soapy water, then rinse clean. Tank is removable. Sediment screen M24778 6. Scouring pads suitable...