Owner's Manual
Page 1
... Switch ...10 Step 7. Operating Your Thermostat ...17 Step 12. Registered Trademark Copyright © 2002 Honeywell • •All Rights Reserved 69-1642 Remove Old Thermostat ...6 Step 3. Mount Thermostat Wallplate ...7 Step 4. Wire Wallplate Terminals ...8 Step 5. Programming ...14 Step 11. Honeywell CT3600/CT3697 PROGRAMMABLE THERMOSTAT OWNER'S GUIDE Seven Day Programmable Heat and/or Cool Low Voltage...
... Switch ...10 Step 7. Operating Your Thermostat ...17 Step 12. Registered Trademark Copyright © 2002 Honeywell • •All Rights Reserved 69-1642 Remove Old Thermostat ...6 Step 3. Mount Thermostat Wallplate ...7 Step 4. Wire Wallplate Terminals ...8 Step 5. Programming ...14 Step 11. Honeywell CT3600/CT3697 PROGRAMMABLE THERMOSTAT OWNER'S GUIDE Seven Day Programmable Heat and/or Cool Low Voltage...
Owner's Manual
Page 3
... Return DIGITAL DISPLAY RAISES TEMPERATURE SETTING LOWERS TEMPERATURE SETTING DISPLAYS CURRENT HEAT/COOL TEMPERATURE SETTING PROGRAM PERIODS WAKE/LEAVE/RETURN/SLEEP: ENTERS PROGRAMMING MODE Sleep HOLD TEMP SETS A HOLD TEMPERATURE SETTING AND ACTIVATES VACATION HOLD FEATURE Hold Temp Day Daylight Time Heat/Cool Settings Copy Usage Heat Off ... SETS DAY OF THE WEEK DAYLIGHT TIME SELECTS STANDARD TIME OR DAYLIGHT SAVINGS TIME COPY COPY SETTINGS FROM ONE DAY TO ANOTHER DAY FOR QUICK PROGRAMMING HEAT/COOL SETTING SWITCHES BETWEEN HEAT SETPOINTS AND COOL SETPOINTS WHILE...
... Return DIGITAL DISPLAY RAISES TEMPERATURE SETTING LOWERS TEMPERATURE SETTING DISPLAYS CURRENT HEAT/COOL TEMPERATURE SETTING PROGRAM PERIODS WAKE/LEAVE/RETURN/SLEEP: ENTERS PROGRAMMING MODE Sleep HOLD TEMP SETS A HOLD TEMPERATURE SETTING AND ACTIVATES VACATION HOLD FEATURE Hold Temp Day Daylight Time Heat/Cool Settings Copy Usage Heat Off ... SETS DAY OF THE WEEK DAYLIGHT TIME SELECTS STANDARD TIME OR DAYLIGHT SAVINGS TIME COPY COPY SETTINGS FROM ONE DAY TO ANOTHER DAY FOR QUICK PROGRAMMING HEAT/COOL SETTING SWITCHES BETWEEN HEAT SETPOINTS AND COOL SETPOINTS WHILE...
Owner's Manual
Page 4
...HEAT OR COOL SHOWS SMART RESPONSE IS CHANGING THE TEMPERATURE TO MEET THE CURRENT PROGRAMS M16421C 69-1642 4 DISPLAYS EITHER CURRENT TIME OF DAY OR PROGRAM TIMES SHOWS WHEN THERMOSTAT IS IN THE PROGRAMMING MODE SHOWS THERMOSTAT IS IN THE SET DAY/TIME MODE SHOWS TEMPERATURE SETTING CHANGED... FOR THIS PROGRAM PERIOD SHOWS VACATION HOLD DURATION SHOWS CURRENT DAY OR DAYS BEING PROGRAMMED SHOWS CURRENT PROGRAM PERIOD OR PERIOD BEING PROGRAMMED Set Program Set Day/Time Temporary Setting Hold for Em Ht AM Room Aux Ht ...
...HEAT OR COOL SHOWS SMART RESPONSE IS CHANGING THE TEMPERATURE TO MEET THE CURRENT PROGRAMS M16421C 69-1642 4 DISPLAYS EITHER CURRENT TIME OF DAY OR PROGRAM TIMES SHOWS WHEN THERMOSTAT IS IN THE PROGRAMMING MODE SHOWS THERMOSTAT IS IN THE SET DAY/TIME MODE SHOWS TEMPERATURE SETTING CHANGED... FOR THIS PROGRAM PERIOD SHOWS VACATION HOLD DURATION SHOWS CURRENT DAY OR DAYS BEING PROGRAMMED SHOWS CURRENT PROGRAM PERIOD OR PERIOD BEING PROGRAMMED Set Program Set Day/Time Temporary Setting Hold for Em Ht AM Room Aux Ht ...
Owner's Manual
Page 9
... 5. Connect O to Rc. Table 2. Terminal Designations on Old and New Thermostats Terminal on Old Thermostat Connect To Description R, RHa, 4, V R Power Rc, Ra Rc Power for programming and operation of the wire with electrical tape and push the taped wire back into the wiring hole in heat. (Single stage heat pump only...
... 5. Connect O to Rc. Table 2. Terminal Designations on Old and New Thermostats Terminal on Old Thermostat Connect To Description R, RHa, 4, V R Power Rc, Ra Rc Power for programming and operation of the wire with electrical tape and push the taped wire back into the wiring hole in heat. (Single stage heat pump only...
Owner's Manual
Page 12
... furnace. To turn Smart Response technology on (preset). - 1 = Smart Response technology off : ❑ Press once. ❑ Press Time to move to next feature or Run Program to return to main display. Time Format (Feature Number 16) Time format options are : - 0 = °F (preset). - 1 = °C. NOTE: See Smart Response ...: ❑ Press until display shows your furnace or boiler type. ❑ Press Time to move to next feature or Run Program to return to main display. To change temperature format: ❑ Press once. ❑ Press Time to move to next feature or Run...
... furnace. To turn Smart Response technology on (preset). - 1 = Smart Response technology off : ❑ Press once. ❑ Press Time to move to next feature or Run Program to return to main display. Time Format (Feature Number 16) Time format options are : - 0 = °F (preset). - 1 = °C. NOTE: See Smart Response ...: ❑ Press until display shows your furnace or boiler type. ❑ Press Time to move to next feature or Run Program to return to main display. To change temperature format: ❑ Press once. ❑ Press Time to move to next feature or Run...
Owner's Manual
Page 13
... Day/Time will advance the time in one ❑ Press Daylight Time until "DST" displays if daylight savings time is in effect. ❑ Press Run Program . 13 69-1642 Factory Set Function (Feature Number 37) Do not change time format: ❑ Press once. ❑ Press Run...
... Day/Time will advance the time in one ❑ Press Daylight Time until "DST" displays if daylight savings time is in effect. ❑ Press Run Program . 13 69-1642 Factory Set Function (Feature Number 37) Do not change time format: ❑ Press once. ❑ Press Run...
Owner's Manual
Page 14
...while you are sleeping. (This is a higher temperature during the heating season and a lower temperature during the cooling season). Leave -The program period you can set for work or school. (This is a lower temperature during the heating season and a higher temperature during the cooling ...season.) 69-1642 14 PROGRAMMING The keyboard is a higher temperature during the heating season and a lower temperature during the cooling season). The three most frequently used keys...
...while you are sleeping. (This is a higher temperature during the heating season and a lower temperature during the cooling season). Leave -The program period you can set for work or school. (This is a lower temperature during the heating season and a higher temperature during the cooling ...season.) 69-1642 14 PROGRAMMING The keyboard is a higher temperature during the heating season and a lower temperature during the cooling season). The three most frequently used keys...
Owner's Manual
Page 15
.... Saturday Sunday (Sat) (Sun) Program the First Day Start by programming the wake time and temperature for one day. ❑ Press and release Wake . ❑ Press Day until the desired day displays. (Mon, Tue, Wed, Thu, ...
.... Saturday Sunday (Sat) (Sun) Program the First Day Start by programming the wake time and temperature for one day. ❑ Press and release Wake . ❑ Press Day until the desired day displays. (Mon, Tue, Wed, Thu, ...
Owner's Manual
Page 16
...40°F to 90°F (4.5°C to 32°C) for heating and 45°F to 99°F (7°C to 37°C) for each step in Program the First Day for heating and cooling. ❑ Press or until the desired wake temperature displays. Copy a Day Your thermostat can copy...can copy that day to any other day using procedure in 15 minute intervals. NOTE: Program times are in Copy a Day. ❑ Press Run Program when the entire week is programmed, you want to switch between setpoints. NOTE: Program times are the same for the rest of the week. The display shows. NOTE: After...
...40°F to 90°F (4.5°C to 32°C) for heating and 45°F to 99°F (7°C to 37°C) for each step in Program the First Day for heating and cooling. ❑ Press or until the desired wake temperature displays. Copy a Day Your thermostat can copy...can copy that day to any other day using procedure in 15 minute intervals. NOTE: Program times are in Copy a Day. ❑ Press Run Program when the entire week is programmed, you want to switch between setpoints. NOTE: Program times are the same for the rest of the week. The display shows. NOTE: After...
Owner's Manual
Page 17
...temperature clear. ❑ Repeat the above steps for each period to . Temporary appears in the display. The setting cancels when the next program period starts or when you want to copy. Mon Wed ❑ Press Copy to accept the change. ❑ Repeat these steps for... appears for about 3 seconds and then the room temperature is displayed for two seconds and then the normal program display appears. OPERATING YOUR THERMOSTAT Change Temperature Setting Until the Next Program Period (Temporary Change) ❑ Press or until the screen shows the desired temperature setting. Clear...
...temperature clear. ❑ Repeat the above steps for each period to . Temporary appears in the display. The setting cancels when the next program period starts or when you want to copy. Mon Wed ❑ Press Copy to accept the change. ❑ Repeat these steps for... appears for about 3 seconds and then the room temperature is displayed for two seconds and then the normal program display appears. OPERATING YOUR THERMOSTAT Change Temperature Setting Until the Next Program Period (Temporary Change) ❑ Press or until the screen shows the desired temperature setting. Clear...
Owner's Manual
Page 18
... daylight savings time. For example, one hour. DST is displayed. ❑ Press Wake , , Leave Return or Sleep to select the program period when you to switch between standard time and daylight savings time. ❑ Press Daylight Time during fall to set the time back one... six times in a five minute period scrolls you to your setting if desired. (The display changes from showing the setpoint temperature to the program. NOTE: If the Vacation Hold needs to be away (1 through various time options. Change the Temperature Setting Until a Designated Day and Period...
... daylight savings time. For example, one hour. DST is displayed. ❑ Press Wake , , Leave Return or Sleep to select the program period when you to switch between standard time and daylight savings time. ❑ Press Daylight Time during fall to set the time back one... six times in a five minute period scrolls you to your setting if desired. (The display changes from showing the setpoint temperature to the program. NOTE: If the Vacation Hold needs to be away (1 through various time options. Change the Temperature Setting Until a Designated Day and Period...
Owner's Manual
Page 20
... the room temperature. • Make sure the circuit breaker is not tripped, and reset it is coming from the registers. Display flashes during programming. Heating does not come on the wallplate if it if necessary. • Make sure the power switch at the wrong times. 1. Make ...correct. 4. Solution Guide. Wait five minutes after seeing the flame or snowflake and check the registers again. Reprogram any incorrect settings. Check the program times for the period in the Off position. • Wait five minutes for the system to respond. • Set the system switch to...
... the room temperature. • Make sure the circuit breaker is not tripped, and reset it is coming from the registers. Display flashes during programming. Heating does not come on the wallplate if it if necessary. • Make sure the power switch at the wrong times. 1. Make ...correct. 4. Solution Guide. Wait five minutes after seeing the flame or snowflake and check the registers again. Reprogram any incorrect settings. Check the program times for the period in the Off position. • Wait five minutes for the system to respond. • Set the system switch to...