HP DTC Cabling and Racking Guide
Page 9
... ordering a stand-alone computer rack, you plan to order filler panels for 19" (482.6 mm) racks. European computer racks all have options for the power supply in EIA (Electronic Industries Association) units. 2 HP System Racks The HP System Racks conform to prevent current overloads. One EIA unit equals 44.45 mm (1.75 inches).
... ordering a stand-alone computer rack, you plan to order filler panels for 19" (482.6 mm) racks. European computer racks all have options for the power supply in EIA (Electronic Industries Association) units. 2 HP System Racks The HP System Racks conform to prevent current overloads. One EIA unit equals 44.45 mm (1.75 inches).
HP DTC Cabling and Racking Guide
Page 112
Index S standard cable lengths 75 system racks 1.1 meter 5 1.6 meter 4 DTC racking order 6 EIA units 3 guidelines for racking systems 6 HP 3 non-HP 13 populating 11 power supply 3 product numbers 6 rails 6 rear door 5 T twisted pair cables 84 typical configurations 29 V V.35 cable 98 X X.25 boards 97 106
Index S standard cable lengths 75 system racks 1.1 meter 5 1.6 meter 4 DTC racking order 6 EIA units 3 guidelines for racking systems 6 HP 3 non-HP 13 populating 11 power supply 3 product numbers 6 rails 6 rear door 5 T twisted pair cables 84 typical configurations 29 V V.35 cable 98 X X.25 boards 97 106
nPartition Administrator's Guide, Second Edition
Page 6
... 199 7 Managing Hardware Resources 201 Tools for Managing Hardware...201 Task Summaries for Hardware Resource Management 201 Powering Server Cabinets On and Off 205 Powering Cells and I/O Chassis On and Off 206 Turning Attention Indicators (LEDs) On and Off 209 Configuring ... a Server Complex 234 Listing Product and Serial Numbers 235 Listing nPartition Configurations...236 Listing the Local nPartition Number 237 Listing Power Status and Power Supplies 238 Listing Fan and Blower Status...240 A nPartition Commands 243 Specifying Cells and I/O Chassis to Commands 243 Cell Specification...
... 199 7 Managing Hardware Resources 201 Tools for Managing Hardware...201 Task Summaries for Hardware Resource Management 201 Powering Server Cabinets On and Off 205 Powering Cells and I/O Chassis On and Off 206 Turning Attention Indicators (LEDs) On and Off 209 Configuring ... a Server Complex 234 Listing Product and Serial Numbers 235 Listing nPartition Configurations...236 Listing the Local nPartition Number 237 Listing Power Status and Power Supplies 238 Listing Fan and Blower Status...240 A nPartition Commands 243 Specifying Cells and I/O Chassis to Commands 243 Cell Specification...
nPartition Administrator's Guide, Second Edition
Page 222
... accessing Partition Manager or other DIMMs in the following procedure. Use dimmconfig cell to check the operating status of cells, I/O chassis, fans and blowers, and power supplies. Enter the help dimmconfig command for Managing Hardware" (page 201). 2. Partition Manager displays a report of a cell-based server by using the Partition Manager Complex→...
... accessing Partition Manager or other DIMMs in the following procedure. Use dimmconfig cell to check the operating status of cells, I/O chassis, fans and blowers, and power supplies. Enter the help dimmconfig command for Managing Hardware" (page 201). 2. Partition Manager displays a report of a cell-based server by using the Partition Manager Complex→...
nPartition Administrator's Guide, Second Edition
Page 226
... displays detailed information about the individual cells in the server, and cell assignments to the service processor Main Menu. frupower -d -I /O chassis power status. • Partition Manager: - See "Listing Power Status and Power Supplies" (page 238). Version 1.0 - "Listing Fan and Blower Status" • Service Processor (MP or GSP): PS command, B option for detailed fan and...
... displays detailed information about the individual cells in the server, and cell assignments to the service processor Main Menu. frupower -d -I /O chassis power status. • Partition Manager: - See "Listing Power Status and Power Supplies" (page 238). Version 1.0 - "Listing Fan and Blower Status" • Service Processor (MP or GSP): PS command, B option for detailed fan and...
nPartition Administrator's Guide, Second Edition
Page 234
...the cabinet option to view a detailed status for the server cabinet whose configuration and details you want to view: • On HP Superdome servers, select the B (cabinet) option, and specify the cabinet whose information you can login to exit the service processor...the service processor Main Menu. At the Main Menu, enter X to any one of cells, I/O chassis, power supplies, utilities, fans, firmware components, interconnecting hardware. Other information such as the power status, faults, and LED states also are given. List all hardware in the server complex. • parstatus...
...the cabinet option to view a detailed status for the server cabinet whose configuration and details you want to view: • On HP Superdome servers, select the B (cabinet) option, and specify the cabinet whose information you can login to exit the service processor...the service processor Main Menu. At the Main Menu, enter X to any one of cells, I/O chassis, power supplies, utilities, fans, firmware components, interconnecting hardware. Other information such as the power status, faults, and LED states also are given. List all hardware in the server complex. • parstatus...
nPartition Administrator's Guide, Second Edition
Page 238
... to list the local nPartition number. Select the nPartition console. Exit the console and service processor interfaces if finished using WBEM involves remote management on HP Integrity systems. 1. Only remote management using them . Issue the parstatus -w command to list power status and power supply details for cabinets, cells, and I/O chassis; and related details.
... to list the local nPartition number. Select the nPartition console. Exit the console and service processor interfaces if finished using WBEM involves remote management on HP Integrity systems. 1. Only remote management using them . Issue the parstatus -w command to list power status and power supply details for cabinets, cells, and I/O chassis; and related details.
nPartition Administrator's Guide, Second Edition
Page 239
... cabinet number). • frupower -d -C - Procedure 8-34 Listing Power Status and Power Supplies (Partition Manager) You can login to any system with the nPartition commands installed. Access Partition Manager. List power status and power supply details for the cabinet whose power status and related details you want to view: • On HP Superdome servers, select the B (cabinet) option, and...
... cabinet number). • frupower -d -C - Procedure 8-34 Listing Power Status and Power Supplies (Partition Manager) You can login to any system with the nPartition commands installed. Access Partition Manager. List power status and power supply details for the cabinet whose power status and related details you want to view: • On HP Superdome servers, select the B (cabinet) option, and...
Generic Site Preparation Guide, Fourth Edition
Page 5
List of Figures 1-1 Raised Floor Metal Strip Ground System 14 1-2 C20 Male Receptacle (at Power Supply 27 1-3 C19 Female Plug (on One End of the Power Cord 27 1-4 Unterminated Plug...27 1-5 L6-20 Plug...27 1-6 IEC 309 Plug...28 1-7 CEE 7-7 Plug...28 1-8 L6-30 Plug...28 1-9 NEMA 5-20P Plug (left) and receptacle (right 28 1-10 ISI 32 Plug...28 1-11 GB 1002 Plug...29 1-12 L6-20 Power Cable...29 1-13 Delivery Survey (Part 1)...33 1-14 Delivery Survey (Part 2)...34 5
List of Figures 1-1 Raised Floor Metal Strip Ground System 14 1-2 C20 Male Receptacle (at Power Supply 27 1-3 C19 Female Plug (on One End of the Power Cord 27 1-4 Unterminated Plug...27 1-5 L6-20 Plug...27 1-6 IEC 309 Plug...28 1-7 CEE 7-7 Plug...28 1-8 L6-30 Plug...28 1-9 NEMA 5-20P Plug (left) and receptacle (right 28 1-10 ISI 32 Plug...28 1-11 GB 1002 Plug...29 1-12 L6-20 Power Cable...29 1-13 Delivery Survey (Part 1)...33 1-14 Delivery Survey (Part 2)...34 5
Generic Site Preparation Guide, Fourth Edition
Page 8
...This grounding is in the beginning, but realize that are appropriate for the highest availability environment. Use uninterruptible power supplies (UPSs), backup generators, auto transfer devices, floor-mounted distribution transformers (less than down. Undersizing the wiring might take... place with the electrical infrastructure. HP does not recommend the practice of the room, and develop a growth plan for maximum equipment availability and use a ...
...This grounding is in the beginning, but realize that are appropriate for the highest availability environment. Use uninterruptible power supplies (UPSs), backup generators, auto transfer devices, floor-mounted distribution transformers (less than down. Undersizing the wiring might take... place with the electrical infrastructure. HP does not recommend the practice of the room, and develop a growth plan for maximum equipment availability and use a ...
Generic Site Preparation Guide, Fourth Edition
Page 18
...to excess heat or humidity buildup on the airflow, temperature, particulate contamination, and power distribution of device. One method to determine their possible presence is to power supplies and other electronic components can be present. dull - electroplating: most susceptible for ...temperature and humidity are measured at : http://standards.corp.hp.com/ smc/hpstd/pdf/F-HP0000501.pdf. Airflow Ensure...
...to excess heat or humidity buildup on the airflow, temperature, particulate contamination, and power distribution of device. One method to determine their possible presence is to power supplies and other electronic components can be present. dull - electroplating: most susceptible for ...temperature and humidity are measured at : http://standards.corp.hp.com/ smc/hpstd/pdf/F-HP0000501.pdf. Airflow Ensure...
Generic Site Preparation Guide, Fourth Edition
Page 27
... 1-5 L6-20 Plug Power Plug Configuration 27 Female End of Power Cable The female end of the power cable will vary depending on the region the HP server ships. Figure 1-2 C20 Male Receptacle (at Power Supply) Figure 1-3 C19 Female Plug (on One End of the Power Cord) Male End of Power Cable The male plug ...on the other end of the HP server ...
... 1-5 L6-20 Plug Power Plug Configuration 27 Female End of Power Cable The female end of the power cable will vary depending on the region the HP server ships. Figure 1-2 C20 Male Receptacle (at Power Supply) Figure 1-3 C19 Female Plug (on One End of the Power Cord) Male End of Power Cable The male plug ...on the other end of the HP server ...
Generic Site Preparation Guide, Fourth Edition
Page 37
... on, they present high initial currents as the product of root mean square (RMS) current times RMS voltage, without taking the power factor into a power supply the instant AC power is commonly found in . (1 U equals 44.45 mm). Kilovolt-amperes (1,000 x volt-amperes). The term does not necessarily...lines and ground. 37 The peak inrush current can be 1.75 inches in an hour, a common measure of heat transfer rate. In power supplies, leakage current usually refers to the 60-Hz current, which is called a card or adapter. Also called CompactPCI. D-K daisy chain dehumidification...
... on, they present high initial currents as the product of root mean square (RMS) current times RMS voltage, without taking the power factor into a power supply the instant AC power is commonly found in . (1 U equals 44.45 mm). Kilovolt-amperes (1,000 x volt-amperes). The term does not necessarily...lines and ground. 37 The peak inrush current can be 1.75 inches in an hour, a common measure of heat transfer rate. In power supplies, leakage current usually refers to the 60-Hz current, which is called a card or adapter. Also called CompactPCI. D-K daisy chain dehumidification...
Generic Site Preparation Guide, Fourth Edition
Page 38
...typical load and target voltage. O-R PCA PCI PICMG power factor RMS Printed Circuit Assembly, also referred to the power supply. S-T theoretical maximum power consumption tonnage true power typical input current typical power consumption Maximum wattage of a given configuration, assuming worst..., temperature, humidity, fire, earthquake, vibration, transportation, acoustics, air quality, and illumination. Represents the expected power consumption of safety guidelines. Vapor barriers can be present. Network Equipment Building Standards. The Federal Communications Commission (...
...typical load and target voltage. O-R PCA PCI PICMG power factor RMS Printed Circuit Assembly, also referred to the power supply. S-T theoretical maximum power consumption tonnage true power typical input current typical power consumption Maximum wattage of a given configuration, assuming worst..., temperature, humidity, fire, earthquake, vibration, transportation, acoustics, air quality, and illumination. Represents the expected power consumption of safety guidelines. Vapor barriers can be present. Network Equipment Building Standards. The Federal Communications Commission (...
Site Preparation Guide, Fourth Edition - HP Integrity rx7640 and HP 9000 rp7440 Servers
Page 3
...This Document...9 Intended Audience...9 Publishing History...9 Related Information...10 Typographic Conventions...11 HP Encourages Your Comments...12 1 HP Integrity rx7640 Server and HP 9000 rp7440 Server Overview 13 Detailed Server Description...13 Dimensions and Components...14 Front Panel... AC Power Specifications...30 Power Cords...30 System Power Specifications...31 Environmental Specifications...32 Temperature and Humidity...32 Operating Environment...32 Environmental Temperature Sensor 33 Non-Operating Environment...33 Cooling...33 Internal Chassis Cooling...33 Bulk Power Supply Cooling...
...This Document...9 Intended Audience...9 Publishing History...9 Related Information...10 Typographic Conventions...11 HP Encourages Your Comments...12 1 HP Integrity rx7640 Server and HP 9000 rp7440 Server Overview 13 Detailed Server Description...13 Dimensions and Components...14 Front Panel... AC Power Specifications...30 Power Cords...30 System Power Specifications...31 Environmental Specifications...32 Temperature and Humidity...32 Operating Environment...32 Environmental Temperature Sensor 33 Non-Operating Environment...33 Cooling...33 Internal Chassis Cooling...33 Bulk Power Supply Cooling...
Site Preparation Guide, Fourth Edition - HP Integrity rx7640 and HP 9000 rp7440 Servers
Page 13
... valid UUID is recommended for existing hardware service restoration. 1 HP Integrity rx7640 Server and HP 9000 rp7440 Server Overview The HP Integrity rx7640 and HP 9000 rp7440 Servers are required and the other two provide power source redundancy. This step is vital when performing upgrades and is...The server is a unit of HP's business-critical computing platform family in chapters one DAT drive. • Two front chassis mounted N+1 fans. • Two rear chassis mounted N+1 fans. • Six N+1 PCI-X card cage fans. • Two N+1 bulk power supplies. • N+1 hot-swappable ...
... valid UUID is recommended for existing hardware service restoration. 1 HP Integrity rx7640 Server and HP 9000 rp7440 Server Overview The HP Integrity rx7640 and HP 9000 rp7440 Servers are required and the other two provide power source redundancy. This step is vital when performing upgrades and is...The server is a unit of HP's business-critical computing platform family in chapters one DAT drive. • Two front chassis mounted N+1 fans. • Two rear chassis mounted N+1 fans. • Six N+1 PCI-X card cage fans. • Two N+1 bulk power supplies. • N+1 hot-swappable ...
Site Preparation Guide, Fourth Edition - HP Integrity rx7640 and HP 9000 rp7440 Servers
Page 14
... Block Diagram Cell Board 0 Memory Cell Board 0 Memory PDH CPU CPU CC CPU CPU CPU CPU CC CPU CPU CC Link Bulk Power Supply (x2) Clocks Reset System Backplane PCI-X Power (x2) Indicates hot pluggable link or bus Indicates cable SBA Link SBA LBA LBA LBA LBA LBA LBA LBA LBA SBA LBA... Disk Disk Disk SCSI SCSI LAN SCSI MP SCSI MP LAN/SCSI Boards Dimensions and Components The following section describes server dimensions and components. 14 HP Integrity rx7640 Server and HP 9000 rp7440 Server Overview
... Block Diagram Cell Board 0 Memory Cell Board 0 Memory PDH CPU CPU CC CPU CPU CPU CPU CC CPU CPU CC Link Bulk Power Supply (x2) Clocks Reset System Backplane PCI-X Power (x2) Indicates hot pluggable link or bus Indicates cable SBA Link SBA LBA LBA LBA LBA LBA LBA LBA LBA SBA LBA... Disk Disk Disk SCSI SCSI LAN SCSI MP SCSI MP LAN/SCSI Boards Dimensions and Components The following section describes server dimensions and components. 14 HP Integrity rx7640 Server and HP 9000 rp7440 Server Overview
Site Preparation Guide, Fourth Edition - HP Integrity rx7640 and HP 9000 rp7440 Servers
Page 16
... without removal of the bezel. Figure 1-4 Right-Front View PCI-X cards Front Panel Display Board PCI Power Supplies Cell Boards B Bulk Power Supplies Access the PCI-X card section, located toward the rear, by removing the top cover. This is especially...HP 9000 rp7440 Server Overview The server has the following dimensions: • Depth: Defined by cable management constraints to fit into standard 36-inch deep rack: 25.5 inches from front rack column to PCI connector surface 26.7 inches from the front of the server after removing the front bezel. Install these power supplies...
... without removal of the bezel. Figure 1-4 Right-Front View PCI-X cards Front Panel Display Board PCI Power Supplies Cell Boards B Bulk Power Supplies Access the PCI-X card section, located toward the rear, by removing the top cover. This is especially...HP 9000 rp7440 Server Overview The server has the following dimensions: • Depth: Defined by cable management constraints to fit into standard 36-inch deep rack: 25.5 inches from front rack column to PCI connector surface 26.7 inches from the front of the server after removing the front bezel. Install these power supplies...
Site Preparation Guide, Fourth Edition - HP Integrity rx7640 and HP 9000 rp7440 Servers
Page 17
... Front Panel Front Panel Indicators and Controls The front panel, located on the front panel: • Locate LED (blue) • Power LED (tri-color) • Management processor (MP) status LED (tri-color) • Cell 0, 1 status (tri-color) LEDs Detailed Server Description ...The following status LEDs are on the front of the server, includes the power switch. Four OLR system fan modules, externally attached to the system backplane provides DC power distribution. The two hot-pluggable N+1 redundant bulk power supplies provide a wide input voltage range. A cable harness that connects from ...
... Front Panel Front Panel Indicators and Controls The front panel, located on the front panel: • Locate LED (blue) • Power LED (tri-color) • Management processor (MP) status LED (tri-color) • Cell 0, 1 status (tri-color) LEDs Detailed Server Description ...The following status LEDs are on the front of the server, includes the power switch. Four OLR system fan modules, externally attached to the system backplane provides DC power distribution. The two hot-pluggable N+1 redundant bulk power supplies provide a wide input voltage range. A cable harness that connects from ...
Site Preparation Guide, Fourth Edition - HP Integrity rx7640 and HP 9000 rp7440 Servers
Page 22
... Drive 1-2 Path: 1/0/1/1/0/4/1.6.0 Drive 0-2 Path: 0/0/1/1/0/4/1.5.0 Drive 0-1 Path: 0/0/0/3/0.6.0 22 HP Integrity rx7640 Server and HP 9000 rp7440 Server Overview Both of the bottom disk drives connect to cell 0 through the core I /O devices and racks, management and interconnecting hardware, power supplies, and fans. A server complex can run a single instance of the operating system... system or as multiple systems. NOTE: Partition configuration information is available on the Web at: http://docs.hp.com Refer to HP System Partitions Guide: Administration for nPartitions for details.
... Drive 1-2 Path: 1/0/1/1/0/4/1.6.0 Drive 0-2 Path: 0/0/1/1/0/4/1.5.0 Drive 0-1 Path: 0/0/0/3/0.6.0 22 HP Integrity rx7640 Server and HP 9000 rp7440 Server Overview Both of the bottom disk drives connect to cell 0 through the core I /O devices and racks, management and interconnecting hardware, power supplies, and fans. A server complex can run a single instance of the operating system... system or as multiple systems. NOTE: Partition configuration information is available on the Web at: http://docs.hp.com Refer to HP System Partitions Guide: Administration for nPartitions for details.