HP StorageWorks 7400 - Virtual Array Support and Manuals
Get Help and Manuals for this Hewlett-Packard item
This item is in your list!
View All Support Options Below
Free HP StorageWorks 7400 manuals!
Problems with HP StorageWorks 7400?
Ask a Question
Free HP StorageWorks 7400 manuals!
Problems with HP StorageWorks 7400?
Ask a Question
Popular HP StorageWorks 7400 Manual Pages
ISS Technology Update, Volume 9 Number 1 - Page 1
... Supply Technology
http://techcomm.cca.hp.com/whitepapers/2009/TC091110TB.pdf
HP ProLiant 100-series Intel-based G6 server technology, 3rd edition
http://techcomm.cca.hp.com/WhitePapers/2009/TC091203TB.pdf
HP Smart Array Controller technology, 3rd edition
http://techcomm.cca.hp.com/WhitePapers/2009/TC091204TB.pdf
Using HP ProLiant Network Teaming Software with Microsoft® Windows®...
ISS Technology Update, Volume 9 Number 1 - Page 4
... as shown in the currently released BIOS updates. Operating systems and applications can configure the server such that are configured with Systems ROMPaq Firmware Upgrade for single-core operation is based on ProLiant AMD 100 series servers) G5 and G6 servers using earlier models of support for HP ProLiant DL385 G5 (A09) Servers Version: 2009.07.11...
Disk Drive and Power Supply LED Behavior - Page 1
...drive.
*Controlled by the disk drive. **Controlled by the array controller. See Table 1 for troubleshooting procedures.)
Table 1: VA7100 / VA7400 Disk Drive LEDs Status Indications...HP StorageWorks Virtual Arrays VA 7000 Family User's and Service Guide for a full list of disk LED behaviors.
Disk Drive LED Behavior VA7100 / VA7400
Figure 1: Disk Drive LEDs
B A
A
B
Note After installation...
Disk Hardware Component Replacement Instructions - Page 1
... modules are fragile.
over
Manufacturing Part Number
*A6191-96003* hp surestore virtual arrays
and disk systems
disk replacement
CAUTION
Parts can cause high energy discharge and permanently damage the disk.
Wait for the disk to find system and configuration specific disk replacement procedures.
Please go to
http://www.hp.com/support/storage_self_repair
to stop before pulling...
Power Supply Hardware Component Replacement Instructions - Page 1
... Printed in the same array enclosure for the array: the older A6211-69001 and the newer A6211-96002. To ensure proper array operation, the power supplies should not be damaged by electrostatic discharge. over
Manufacturing Part Number
*A6183-96103* Use proper ESD protection. hp surestore virtual arrays
and disk systems
power supply replacement
CAUTION
Parts can be mixed in...
Power Supply System/Configuration Specific Instructions - Page 1
... power cord from the slot (C in the same array enclosure for more than 2 minutes, as possible when troubleshooting indicates a power supply failure. Replacement Procedure: HP StorageWorks Virtual Arrays and Disk Systems Power Supply
Replace a power supply as soon as proper cooling/airflow depends on locating the power supply part number. When a power supply fails, the remaining power...
Disk System/Configuration Specific Instructions - Page 1
... damage the disc. Be sure you have the replacement parts and are fragile and ESD sensitive. Replacement Procedure: VA7.x Disk Module, 18GB-36GB-72GB
You can add or replace disks to increase storage capacity or eliminate faults. (See Chapter 3 of the HP StorageWorks Virtual Arrays VA 7000 Family User's and Service Guide for troubleshooting procedures.)
Disks must be Fibre Channel (FC...
Disk System/Configuration Specific Instructions - Page 3
..., further Troubleshooting may need to the disk. If a disk is removed during the AutoFormat process. The amber disk fault LED (B) will also flash.
The green (A) LED will be carried out. (See Chapter 3 of the HP StorageWorks Virtual Arrays VA 7000 Family User's and Service Guide for a full list of the disk format, do not remove a newly installed disk...
Linux Configuration HP VA 7100/7400 - Page 2
.... This means users can also configure the HP Virtual Array 7100/7400 via the RS-232 port on the array controllers using QLogic QLA2100 or QLA2200 fibre channel host bus adapters on Red Hat 6.2 with the 2.2.16-3 and 2.2.19-6.2.7 kernels patched as a set of executable files which are not yet supported.
As tested, the configuration is a direct...
Linux Configuration HP VA 7100/7400 - Page 4
... kernel-BOOT-2.2.16-3.i386.rpm
2.2.19 kernel
Linux kernel 2.2.19 upgrade. See RedHat site (http://www.redhat.com/support/errata/RHSA-2000037-05.html) for background, RPMs and instructions. See RedHat site (https://www.redhat.com/support/errata/RHSA-2001047.html) for background, RPMs and instructions. 2.2.16 kernel
Linux Configuration HP VA 7100/7400
Linux kernel 2.2.16...
Linux Configuration HP VA 7100/7400 - Page 5
... Error Recovery
There are listed here and summarized below. 1. This set of the patch; This includes the "vendor unique data direction" and "16 byte CDB" patches. Follow the links to run HP Command View SDM software on a Linux host. Linux Configuration HP VA 7100/7400
Log in the following patches to the Kernel's SCSI subsystem source code...
Linux Configuration HP VA 7100/7400 - Page 10
..., then there is currently no means in place to manually notify the new error handler that a missing or timed-out device will eventually return to its original position. In any case, this patch is offered as a "SCSI kluge". Linux Configuration HP VA 7100/7400
The major distinguishing behavior of the new recovery function is...
HP StorageWorks Multi-protocol Router XPath OS 7.4.1f release notes (5697-0243, January 2010) - Page 3
...
Table 1 lists compatible HP MP Routers and transceivers. For the MP Router configuration and scalability rules, see the Brocade Compatibility Matrix for iSCSI.
Table 1 Supported MP Routers and transceivers
MP Routers StorageWorks MP Router base (8-port)
Part number A7437A
StorageWorks MP Router full (16-port)
A7438A
Multi-protocol Router upgrade license Transceivers1
A7439A...
HP StorageWorks Multi-protocol Router XPath OS 7.4.1f release notes (5697-0243, January 2010) - Page 4
...An asterisk (*) is displayed next to access this website. Accessing the latest firmware
To access XPath OS 7.4.1f firmware, configuration files, and MIB files, visit the following operating systems. For specific version information, contact an HP Storage representative. • HP-UX • HP OpenVMS • HP Tru64 UNIX • IBM AIX • Microsoft Windows • Novell NetWare...
HP StorageWorks 7400 Reviews
Do you have an experience with the HP StorageWorks 7400 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for HP yet.
Earn 750 points for your review!