HP ProLiant Servers Troubleshooting Guide
Page 9
...HP ProLiant Servers Troubleshooting Guide, part number 375445-xx8, includes the following additions and updates: • Added information to the introduction for the server power-on problems flowchart (on page 26). • Added new steps to Power problems (on page 36). • Added a new section to Fan problems (on page 44): All fans in an HP ProLiant G6 server...The seventh edition of the HP ProLiant Servers Troubleshooting Guide, part number 375445-xx7, included the following additions and updates: • Added new information about Server updates with an HP Trusted Platform Module and ...
...HP ProLiant Servers Troubleshooting Guide, part number 375445-xx8, includes the following additions and updates: • Added information to the introduction for the server power-on problems flowchart (on page 26). • Added new steps to Power problems (on page 36). • Added a new section to Fan problems (on page 44): All fans in an HP ProLiant G6 server...The seventh edition of the HP ProLiant Servers Troubleshooting Guide, part number 375445-xx7, included the following additions and updates: • Added new information about Server updates with an HP Trusted Platform Module and ...
Sun Solaris 10 Deployment Guide for HP ProLiant Servers
Page 7
... on initial deployment of this guide include automated post-installation configuration, application deployment, and operating system upgrades. The number in advanced Solaris deployments, see "Architecture of an installation." Table 1 Applicable HP ProLiant servers BL280c G6 DL320 G5p DL320 G6 Using this guide For effective use of this guide, follow these topics, see the following sections: ○ For...
... on initial deployment of this guide include automated post-installation configuration, application deployment, and operating system upgrades. The number in advanced Solaris deployments, see "Architecture of an installation." Table 1 Applicable HP ProLiant servers BL280c G6 DL320 G5p DL320 G6 Using this guide For effective use of this guide, follow these topics, see the following sections: ○ For...
HP Power Advisor utility: a tool for estimating power requirements for HP ProLiant server systems
Page 3
...is first applied (power cord is residual current that minimizes inrush current. The ProLiant DL380 G6 implements the HP Common Slot Power Supply bay. Figure 1 illustrates how the use the associated... be extracted, knowing the total amount of watts dissipated by equipment determines the number of BTUs/hr required for component cooling, based on ), power supplies of ...the amount of a power supply operating at their rated capacity, using nameplate ratings for ProLiant servers include a chassis nameplate that typically includes the following information: • Input requirement-the...
...is first applied (power cord is residual current that minimizes inrush current. The ProLiant DL380 G6 implements the HP Common Slot Power Supply bay. Figure 1 illustrates how the use the associated... be extracted, knowing the total amount of watts dissipated by equipment determines the number of BTUs/hr required for component cooling, based on ), power supplies of ...the amount of a power supply operating at their rated capacity, using nameplate ratings for ProLiant servers include a chassis nameplate that typically includes the following information: • Input requirement-the...
HP Power Advisor utility: a tool for estimating power requirements for HP ProLiant server systems
Page 4
Rack loading with 20 ProLiant DL380 G6 servers using 750W power supplies (PSs) Wattage per PS...27.6 A 6 - 7kVA However, measurements of test configurations reveal that the actual operating needs of a given DL380 G6 configuration can be removed by the cooling equipment. A power supply requiring 300 watts input to produce 250 watts of ...cumulative energy losses from a number of servers can be necessary, particularly if power redundancy is usually impractical for customers since it reveals the possibility of a better power supply solution. HP has tested server products under load. This ...
Rack loading with 20 ProLiant DL380 G6 servers using 750W power supplies (PSs) Wattage per PS...27.6 A 6 - 7kVA However, measurements of test configurations reveal that the actual operating needs of a given DL380 G6 configuration can be removed by the cooling equipment. A power supply requiring 300 watts input to produce 250 watts of ...cumulative energy losses from a number of servers can be necessary, particularly if power redundancy is usually impractical for customers since it reveals the possibility of a better power supply solution. HP has tested server products under load. This ...
HP Power Advisor utility: a tool for estimating power requirements for HP ProLiant server systems
Page 6
After highlighting a rack, the user selects the Servers or Enclosures tab in a rack and clicking the Config tab. Figure 3. Figure 3 shows a ProLiant DL160 G6 placed in Figure 4, the HP Power Advisor allows the user to select the following components ...server supports power supply redundancy. 6 HP ProLiant DL, SL, and some ML server chassis mount directly into the racks. A power calculation begins with components. For HP ProLiant BL (BladeSystem) components, the user must select a BladeSystem c-Class enclosure and then configure each server individually: • Processor type and number...
After highlighting a rack, the user selects the Servers or Enclosures tab in a rack and clicking the Config tab. Figure 3. Figure 3 shows a ProLiant DL160 G6 placed in Figure 4, the HP Power Advisor allows the user to select the following components ...server supports power supply redundancy. 6 HP ProLiant DL, SL, and some ML server chassis mount directly into the racks. A power calculation begins with components. For HP ProLiant BL (BladeSystem) components, the user must select a BladeSystem c-Class enclosure and then configure each server individually: • Processor type and number...
HP Power Advisor utility: a tool for estimating power requirements for HP ProLiant server systems
Page 12
... have to be a good fit and would provide adequate VA and outlet headroom for server expansion or peripheral devices. Since the ProLiant DL160 G6 accommodates only one example-a number of configurations are possible. Figure 10. 42U rack configuration of 24 HP ProLiant DL160 G6 servers with a remote console, users can be 12785.28 BTU/hr., an amount that...
... have to be a good fit and would provide adequate VA and outlet headroom for server expansion or peripheral devices. Since the ProLiant DL160 G6 accommodates only one example-a number of configurations are possible. Figure 10. 42U rack configuration of 24 HP ProLiant DL160 G6 servers with a remote console, users can be 12785.28 BTU/hr., an amount that...
Drive technology overview
Page 8
... be delivered across the interfaces. SATA 1.5 Gb/s with HP ProLiant G6 servers in three variants: 1.5 Gb/s 1.5 Gb/s with extensions 3.0 Gb/s The initial SATA 1.5 Gb/s variant was targeted at http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00301688/c00301688.pdf Interconnect bandwidths .... For a more detailed discussion of drives in each direction. SAS-2 also supports SAS expanders to create a SAS fabric supporting large numbers of 6 Gb/s, or 600 MB/s, in a SAS fabric, although the practical limit is only achieved using new SAS-2 compliant disk...
... be delivered across the interfaces. SATA 1.5 Gb/s with HP ProLiant G6 servers in three variants: 1.5 Gb/s 1.5 Gb/s with extensions 3.0 Gb/s The initial SATA 1.5 Gb/s variant was targeted at http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00301688/c00301688.pdf Interconnect bandwidths .... For a more detailed discussion of drives in each direction. SAS-2 also supports SAS expanders to create a SAS fabric supporting large numbers of 6 Gb/s, or 600 MB/s, in a SAS fabric, although the practical limit is only achieved using new SAS-2 compliant disk...
Configuring the HP ProLiant Server BIOS for Low-Latency Applications
Page 7
Supported AMP modes depend on HP ProLiant G6 servers and server blades with InfiniBand mezzanine cards installed, upgrade the InfiniBand mezzanine card firmware. Because of the very low frequency of this SMI, only the most recent version. Search the HP website (http://www.hp.com/go/bladesystem) for minimum latency... and model of the features described below are required. BIOS low-latency settings To configure BIOS for the mezzanine card part number. 2. In any case, disabling Memory Pre-Failure Notification does not disable the Advanced ECC mode or correction of the mode...
Supported AMP modes depend on HP ProLiant G6 servers and server blades with InfiniBand mezzanine cards installed, upgrade the InfiniBand mezzanine card firmware. Because of the very low frequency of this SMI, only the most recent version. Search the HP website (http://www.hp.com/go/bladesystem) for minimum latency... and model of the features described below are required. BIOS low-latency settings To configure BIOS for the mezzanine card part number. 2. In any case, disabling Memory Pre-Failure Notification does not disable the Advanced ECC mode or correction of the mode...
Configuring the HP ProLiant Server BIOS for Low-Latency Applications
Page 8
... functionality. The utility is one of SSSTK, can be used to reconfigure the BIOS for configuring these options on HP ProLiant G5 servers and HP ProLiant G6 servers that utilize Intel® Xeon® processors. Go to determine the appropriate method. Use the following : o Download... the latest SmartStart Scripting Toolkit Linux Edition. 4. Enter the server model number and then click >>. 4. The conrep utility provided in HP ProLiant 300 Series or above G5, G6, or G7 servers and server blades depend on the server generation and on the Online ROM Flash Component page. Unpack ...
... functionality. The utility is one of SSSTK, can be used to reconfigure the BIOS for configuring these options on HP ProLiant G5 servers and HP ProLiant G6 servers that utilize Intel® Xeon® processors. Go to determine the appropriate method. Use the following : o Download... the latest SmartStart Scripting Toolkit Linux Edition. 4. Enter the server model number and then click >>. 4. The conrep utility provided in HP ProLiant 300 Series or above G5, G6, or G7 servers and server blades depend on the server generation and on the Online ROM Flash Component page. Unpack ...
HP ProLiant BL280c G6 Server Blade User Guide
Page 38
...Install the DIMM. 9. For mezzanine card locations, see "Interconnect bay numbering and device mapping (on mezzanine 2 connector. To install the component: 1. Remove the server blade (on page 15). Remove the air baffle (on page 13). 2. Power down the server blade (on page 15). 6. If removed, connect the hard drive...DIMM installation" on page 9). Optional mezzanine cards enable network connectivity or provide Fibre Channel support. For mezzanine card mapping, see the HP ProLiant BL280c G6 Server Blade Installation Instructions or see the system board components (on page 36). 7. 3.
...Install the DIMM. 9. For mezzanine card locations, see "Interconnect bay numbering and device mapping (on mezzanine 2 connector. To install the component: 1. Remove the server blade (on page 15). Remove the air baffle (on page 13). 2. Power down the server blade (on page 15). 6. If removed, connect the hard drive...DIMM installation" on page 9). Optional mezzanine cards enable network connectivity or provide Fibre Channel support. For mezzanine card mapping, see the HP ProLiant BL280c G6 Server Blade Installation Instructions or see the system board components (on page 36). 7. 3.