Compaq Leadership in Server Innovations
Page 4
... I/O bus in servers 486 SMP Pentium SMP TriFlex and DataFlow Manager X86 servers with in Insight Manager - ECG072/0298 WHITE PAPER COMPAQ LEADERSHIP IN SERVER INNOVATIONS ... 1989 1990 1991 1992 1993 1994 1995 1996 1997 4 PERFORMANCE Multiprocessing x86 server on NT First to next...the first NT TPC-C benchmark Support for 4GB memory in x86 servers Redundant NIC PCI Hot Plug Redundant, hot-pluggable fans MANAGEMENT TOOLS/TCO MANAGEMENT TOOLS/TCO Software management tools for management of Insight Agents with leading management software Customized, proactive web-based ...
... I/O bus in servers 486 SMP Pentium SMP TriFlex and DataFlow Manager X86 servers with in Insight Manager - ECG072/0298 WHITE PAPER COMPAQ LEADERSHIP IN SERVER INNOVATIONS ... 1989 1990 1991 1992 1993 1994 1995 1996 1997 4 PERFORMANCE Multiprocessing x86 server on NT First to next...the first NT TPC-C benchmark Support for 4GB memory in x86 servers Redundant NIC PCI Hot Plug Redundant, hot-pluggable fans MANAGEMENT TOOLS/TCO MANAGEMENT TOOLS/TCO Software management tools for management of Insight Agents with leading management software Customized, proactive web-based ...
ProLiant Server Troubleshooting Guide
Page 224
...Probable Source of the server. 1619- SCSI bus failure detected. Each AC source should be on the Web for power considerations: activeanswers.compaq.com/ aaconfigurator Install the server management board in the correct slot. Refer to 220-volt. 2. Be sure that the... fans are missing or not cabled correctly. continued C-44 HP Servers Troubleshooting Guide Verify SCSI bus cabling. System halted. 1620-Fan Not Present None None None The server management board is not achieved. 1619-Maximum Power ...
...Probable Source of the server. 1619- SCSI bus failure detected. Each AC source should be on the Web for power considerations: activeanswers.compaq.com/ aaconfigurator Install the server management board in the correct slot. Refer to 220-volt. 2. Be sure that the... fans are missing or not cabled correctly. continued C-44 HP Servers Troubleshooting Guide Verify SCSI bus cabling. System halted. 1620-Fan Not Present None None None The server management board is not achieved. 1619-Maximum Power ...
ProLiant Server Troubleshooting Guide
Page 250
...Processor Stepping None The newly installed processor is currently operating, and compare to server-specific user documentation recommendations. 5. Check fans for proper airflow and obstructions. 3. C-70 HP Servers Troubleshooting Guide Please contact Compaq Computer Corporation for a new ROM BIOS to cool. 2. Analyze ambient temperature in which the server is not supported by... Beeps None Probable Source of Problem System has exceeded allowable temperature thresholds. 1801-Microcode Patch Error Missing or Invalid Processor Microcode Patch. Check fans for proper operation. 4.
...Processor Stepping None The newly installed processor is currently operating, and compare to server-specific user documentation recommendations. 5. Check fans for proper airflow and obstructions. 3. C-70 HP Servers Troubleshooting Guide Please contact Compaq Computer Corporation for a new ROM BIOS to cool. 2. Analyze ambient temperature in which the server is not supported by... Beeps None Probable Source of Problem System has exceeded allowable temperature thresholds. 1801-Microcode Patch Error Missing or Invalid Processor Microcode Patch. Check fans for proper operation. 4.
ProLiant Server Troubleshooting Guide
Page 277
... alert D-17 drives D-7, D-8, D-9, D-11, D-12, D-13, D-14, D-15, D-16, D-19, D-20, D-21, D-23, D-24 ECC (error checking and correcting) D-3 fans D-18, D-19 firmware upgrading D-6, D-7, D-16, D-18, D-19, D-21 identify controller data D-23 memory D-2, D-24, D-25 monitor and performance D-7, D-9, D-15, D-24 NVRAM D-5,...Failed B-12 array controllers See controllers array enabler board, POST error messages C-45 ART (Automatic Revision Tracking) 5-18 Ask Compaq A-3 ASR timer failure C-9 ASR-2 (Automatic Server Recovery-2) booting into Diagnostics 5-10 booting operating system 5-14 configuring 5-5, 5-7...
... alert D-17 drives D-7, D-8, D-9, D-11, D-12, D-13, D-14, D-15, D-16, D-19, D-20, D-21, D-23, D-24 ECC (error checking and correcting) D-3 fans D-18, D-19 firmware upgrading D-6, D-7, D-16, D-18, D-19, D-21 identify controller data D-23 memory D-2, D-24, D-25 monitor and performance D-7, D-9, D-15, D-24 NVRAM D-5,...Failed B-12 array controllers See controllers array enabler board, POST error messages C-45 ART (Automatic Revision Tracking) 5-18 Ask Compaq A-3 ASR timer failure C-9 ASR-2 (Automatic Server Recovery-2) booting into Diagnostics 5-10 booting operating system 5-14 configuring 5-5, 5-7...
ProLiant Server Troubleshooting Guide
Page 281
...error occurred prior to this power-up C-2 Correctable Memory Log See IML CPU See processors CPU fan See fans CPU fan controller not responding C-43 CPU fan failure detected C-38, C-39 CPU fan not present C-39 CPU test failed B-2 Critical Error Log See IML critical error occurred prior ...to this power-up C-2, C-3 critical failure detected C-3 critical fan failure detected C-3, C-39 critical fan not present C-39 CSP (Compaq Support Paq) 3-12, 3-13 current SCSI bus cable configuration is not recommended C-45 current system ROM is not ...
...error occurred prior to this power-up C-2 Correctable Memory Log See IML CPU See processors CPU fan See fans CPU fan controller not responding C-43 CPU fan failure detected C-38, C-39 CPU fan not present C-39 CPU test failed B-2 Critical Error Log See IML critical error occurred prior ...to this power-up C-2, C-3 critical failure detected C-3 critical fan failure detected C-3, C-39 critical fan not present C-39 CSP (Compaq Support Paq) 3-12, 3-13 current SCSI bus cable configuration is not recommended C-45 current system ROM is not ...
ProLiant Server Troubleshooting Guide
Page 286
...C-42, C-43, C-44 precautions 6-7 problems 2-20, 2-21 seating 2-20 testing 2-20 ventilation 2-20 fans failure detected C-39, C-40, C-41, C-42 fans not present C-39, C-40, C-41 fatal ROM error: the system ROM is non- Compaq supplied D-9 G graphics 320 x 200 mode color set 0 test failed B-7 graphics 320 x 200 mode... detected C-39 front CPU fan X not present C-40 fuse problems 2-8 FYI, Drive (bay) X is not properly programmed C-4 fault tolerance 2-28, D-11 faxing information to HP A-3 firmware upgrade, caution 4-2 fixed disk 0 does not support DMA mode C-53 fixed disk 0 failed set block mode ...
...C-42, C-43, C-44 precautions 6-7 problems 2-20, 2-21 seating 2-20 testing 2-20 ventilation 2-20 fans failure detected C-39, C-40, C-41, C-42 fans not present C-39, C-40, C-41 fatal ROM error: the system ROM is non- Compaq supplied D-9 G graphics 320 x 200 mode color set 0 test failed B-7 graphics 320 x 200 mode... detected C-39 front CPU fan X not present C-40 fuse problems 2-8 FYI, Drive (bay) X is not properly programmed C-4 fault tolerance 2-28, D-11 faxing information to HP A-3 firmware upgrade, caution 4-2 fixed disk 0 does not support DMA mode C-53 fixed disk 0 failed set block mode ...
Compaq Tips and Tricks for NetWare 5
Page 9
...requires CPQHLTH.NLM v4.04 or later for complete functionality. Although CPQIML.NLM v1.00 is another Compaq server utility designed to provide online readings of all Compaq ProLiant servers. • Redundant or non-redundant status of power supply • System heat output ...display the following information: • Power utilization and consumption: capacity, current usage, available, voltage, and temperature fan speed • Configuration of intelligent power switch (Compaq Power Down Manager) Servers with this feature, just add the SoftPwr parameter to a text editor or spreadsheet ...
...requires CPQHLTH.NLM v4.04 or later for complete functionality. Although CPQIML.NLM v1.00 is another Compaq server utility designed to provide online readings of all Compaq ProLiant servers. • Redundant or non-redundant status of power supply • System heat output ...display the following information: • Power utilization and consumption: capacity, current usage, available, voltage, and temperature fan speed • Configuration of intelligent power switch (Compaq Power Down Manager) Servers with this feature, just add the SoftPwr parameter to a text editor or spreadsheet ...
Compaq Tips and Tricks for NetWare 5
Page 17
...affected by these error messages, you can create an empty text file called SHOWLOGO.NLM and save it today. Error messages include fan failure detection, caution temperature detection caution, power supply monitoring, ECC memory monitoring, and automatic server recovery. SWAP simply produces a ...health error messages are your options: • To prevent the Novell splash screen from the original system to dupe your server configurations. Compaq Tips and Tricks for your server. Here's a quick way to setup your next server. A word of caution: Any programs that ...
...affected by these error messages, you can create an empty text file called SHOWLOGO.NLM and save it today. Error messages include fan failure detection, caution temperature detection caution, power supply monitoring, ECC memory monitoring, and automatic server recovery. SWAP simply produces a ...health error messages are your options: • To prevent the Novell splash screen from the original system to dupe your server configurations. Compaq Tips and Tricks for your server. Here's a quick way to setup your next server. A word of caution: Any programs that ...
Deploying the ProLiant Cluster for NetWare 4.2
Page 1
... and internal hot-plug storage • Redundant hot-plug fans, power supplies, and NICs • Automatic Server Recovery-2 (ASR-2) • ECC protected memory • Integrated Management Display (IMD) • Integrated Remote Console (IRC) • Compaq SmartStart and Compaq Insight Manager The Compaq ProLiant Cluster for NetWare 4.2. Compaq servers and storage deliver on different servers. • No...
... and internal hot-plug storage • Redundant hot-plug fans, power supplies, and NICs • Automatic Server Recovery-2 (ASR-2) • ECC protected memory • Integrated Management Display (IMD) • Integrated Remote Console (IRC) • Compaq SmartStart and Compaq Insight Manager The Compaq ProLiant Cluster for NetWare 4.2. Compaq servers and storage deliver on different servers. • No...
Compaq ProLiant 6400R Servers
Page 3
Contents About This Guide Symbols in Text...vii Symbols on Equipment viii Compaq Technician Notes ix Where to Go for Additional Help ix Integrated Management Display x Telephone Numbers x Chapter 1 Illustrated Parts Catalog Mechanical Parts Exploded ...Server Warnings and Precautions 2-4 Top Access Panel ...2-5 Power On/Standby Switch 2-6 Front Bezel ...2-8 Hot-Plug Fans...2-9 I/O Hot-Plug Fans 2-10 Hot-Plug Dual Redundant CPU Fan Assembly 2-11 External Rear Hot-Plug Redundant System Fan Assembly 2-12 Removable Media and Hard Drives 2-12 Media Storage 2-13 Hot-Plug Hard Drives 2-14 ...
Contents About This Guide Symbols in Text...vii Symbols on Equipment viii Compaq Technician Notes ix Where to Go for Additional Help ix Integrated Management Display x Telephone Numbers x Chapter 1 Illustrated Parts Catalog Mechanical Parts Exploded ...Server Warnings and Precautions 2-4 Top Access Panel ...2-5 Power On/Standby Switch 2-6 Front Bezel ...2-8 Hot-Plug Fans...2-9 I/O Hot-Plug Fans 2-10 Hot-Plug Dual Redundant CPU Fan Assembly 2-11 External Rear Hot-Plug Redundant System Fan Assembly 2-12 Removable Media and Hard Drives 2-12 Media Storage 2-13 Hot-Plug Hard Drives 2-14 ...
Compaq ProLiant 6400R Servers
Page 4
iv Compaq ProLiant 6400R Maintenance and Service Guide Removal and Replacement Procedures continued Cable Folding and Routing Diagrams 2-21 24X or Higher Low-Profile CD-ROM Cable 2-21 Diskette Drive Cable 2-22 External Fan Cable 2-22 Power Supply Cable 2-23 ...Chapter 3 Diagnostics and Troubleshooting Diagnostic Tools Utility Overview 3-1 Default Configuration 3-4 Default Configuration Messages 3-4 Inspect Utility...3-4 Utilities Access...3-5 Running Compaq Utilities 3-5 Power-On Self-Test 3-6 Error Messages of the Power-On Self-Test 3-7 Diagnostics Software 3-20 Steps for Diagnostics...
iv Compaq ProLiant 6400R Maintenance and Service Guide Removal and Replacement Procedures continued Cable Folding and Routing Diagrams 2-21 24X or Higher Low-Profile CD-ROM Cable 2-21 Diskette Drive Cable 2-22 External Fan Cable 2-22 Power Supply Cable 2-23 ...Chapter 3 Diagnostics and Troubleshooting Diagnostic Tools Utility Overview 3-1 Default Configuration 3-4 Default Configuration Messages 3-4 Inspect Utility...3-4 Utilities Access...3-5 Running Compaq Utilities 3-5 Power-On Self-Test 3-6 Error Messages of the Power-On Self-Test 3-7 Diagnostics Software 3-20 Steps for Diagnostics...
Compaq ProLiant 6400R Servers
Page 5
... Service Features 3-61 ROMPaq Error Recovery Options 3-62 ROMPaq Disaster Recovery 3-62 Redundant ROM Image Recovery 3-63 Compaq Insight Manager 3-64 Features ...3-64 Compaq Insight Management Software Architecture 3-65 Chapter 4 Connectors, Switches, and LED Indicators Connectors...4-1 Rear Panel Connectors 4-1 System...SW1 4-7 Processor Core Frequency Switches (SW2 and SW3 4-8 LED Indicators ...4-9 Hot-Plug Power Supply LED Indicators 4-9 Hot-Plug Fan LED Indicators 4-10 Front Bezel LED Indicators 4-11 PCI Hot Plug Board LED Indicators 4-13 Hot-Plug Hard Drives 4-15 Interlock...
... Service Features 3-61 ROMPaq Error Recovery Options 3-62 ROMPaq Disaster Recovery 3-62 Redundant ROM Image Recovery 3-63 Compaq Insight Manager 3-64 Features ...3-64 Compaq Insight Management Software Architecture 3-65 Chapter 4 Connectors, Switches, and LED Indicators Connectors...4-1 Rear Panel Connectors 4-1 System...SW1 4-7 Processor Core Frequency Switches (SW2 and SW3 4-8 LED Indicators ...4-9 Hot-Plug Power Supply LED Indicators 4-9 Hot-Plug Fan LED Indicators 4-10 Front Bezel LED Indicators 4-11 PCI Hot Plug Board LED Indicators 4-13 Hot-Plug Hard Drives 4-15 Interlock...
Compaq ProLiant 6400R Servers
Page 27
... not necessary to turn off the server to replace an I/O hot-plug fan. See "Top Access Panel" earlier in Chapter 4. Lift the hot-plug fan straight out of the fan . 3. 2-10 Compaq ProLiant 6400R Maintenance and Service Guide I /O hot-plug fan: 1. Loosen the thumbscrew located at the top of the chassis . 1 2 Figure 2-6. Remove the top access panel...
... not necessary to turn off the server to replace an I/O hot-plug fan. See "Top Access Panel" earlier in Chapter 4. Lift the hot-plug fan straight out of the fan . 3. 2-10 Compaq ProLiant 6400R Maintenance and Service Guide I /O hot-plug fan: 1. Loosen the thumbscrew located at the top of the chassis . 1 2 Figure 2-6. Remove the top access panel...
Compaq ProLiant 6400R Servers
Page 29
... Ultra2 SCSI simplex board. 2 2-12 Compaq ProLiant 6400R Maintenance and Service Guide External Rear Hot-Plug Redundant System Fan Assembly IMPORTANT: It is amber, the fan has failed. If the LED indicator is green, the fan is working properly. See the section "Hot-Plug Fan LED Indicators" in Chapter 4. Move the fan up and then away from the...
... Ultra2 SCSI simplex board. 2 2-12 Compaq ProLiant 6400R Maintenance and Service Guide External Rear Hot-Plug Redundant System Fan Assembly IMPORTANT: It is amber, the fan has failed. If the LED indicator is green, the fan is working properly. See the section "Hot-Plug Fan LED Indicators" in Chapter 4. Move the fan up and then away from the...
Compaq ProLiant 6400R Servers
Page 33
..." earlier in this chapter. 4. Disconnect the SCSI and power cables from the simplex board . 3. Remove the dual fan assembly. Removing the Ultra2 SCSI simplex board Reverse steps 1 through 6 to the hard drive cage . 6. 2-16 Compaq ProLiant 6400R Maintenance and Service Guide Ultra2 SCSI Simplex Board To remove the Ultra2 SCSI simplex board, 1. Perform the...
..." earlier in this chapter. 4. Disconnect the SCSI and power cables from the simplex board . 3. Remove the dual fan assembly. Removing the Ultra2 SCSI simplex board Reverse steps 1 through 6 to the hard drive cage . 6. 2-16 Compaq ProLiant 6400R Maintenance and Service Guide Ultra2 SCSI Simplex Board To remove the Ultra2 SCSI simplex board, 1. Perform the...
Compaq ProLiant 6400R Servers
Page 39
2-22 Compaq ProLiant 6400R Maintenance and Service Guide Diskette Drive Cable Figure 2-18. Folding and routing diagram of the external fan cable NOTE: The fan cable folding and routing diagram is identical for the external rear hot-plug redundant CPU fan or the external rear hot-plug redundant system fan assembly. Folding and routing diagram of the diskette drive cable with the diskette drive signal extension cable External Fan Cable Figure 2-19.
2-22 Compaq ProLiant 6400R Maintenance and Service Guide Diskette Drive Cable Figure 2-18. Folding and routing diagram of the external fan cable NOTE: The fan cable folding and routing diagram is identical for the external rear hot-plug redundant CPU fan or the external rear hot-plug redundant system fan assembly. Folding and routing diagram of the diskette drive cable with the diskette drive signal extension cable External Fan Cable Figure 2-19.
Compaq ProLiant 6400R Servers
Page 57
... chassis . 6. Power Backplane Board Assembly To remove the power backplane board assembly, 1. Remove the hot-plug fans. Perform the preparation procedures. Remove the Power On/Standby switch. Remove I /O Hot-Plug Fans" earlier in this chapter. 3. 2-40 Compaq ProLiant 6400R Maintenance and Service Guide PCI Hot Plug Switch/LED Board and Cable To remove the PCI...
... chassis . 6. Power Backplane Board Assembly To remove the power backplane board assembly, 1. Remove the hot-plug fans. Perform the preparation procedures. Remove the Power On/Standby switch. Remove I /O Hot-Plug Fans" earlier in this chapter. 3. 2-40 Compaq ProLiant 6400R Maintenance and Service Guide PCI Hot Plug Switch/LED Board and Cable To remove the PCI...
Compaq ProLiant 6400R Servers
Page 65
NOTE: The external rear fan has been removed for clarity. 6 7 Figure 2-48. Removing the T-15 green ground wire screw from the plug assembly. 5 5 Figure 2-47. 2-48 Compaq ProLiant 6400R Maintenance and Service Guide 17. Remove the T-15 green ground wire screw from the plug assembly , and lift the cover up and away from the plug assembly 18. Removing the AC power supply connector from the chassis Remove the two T-15 screws securing the power supply connector to the chassis , then push in the plug assembly .
NOTE: The external rear fan has been removed for clarity. 6 7 Figure 2-48. Removing the T-15 green ground wire screw from the plug assembly. 5 5 Figure 2-47. 2-48 Compaq ProLiant 6400R Maintenance and Service Guide 17. Remove the T-15 green ground wire screw from the plug assembly , and lift the cover up and away from the plug assembly 18. Removing the AC power supply connector from the chassis Remove the two T-15 screws securing the power supply connector to the chassis , then push in the plug assembly .
Compaq ProLiant 6400R Servers
Page 73
... PPMs Fans Power-On Self-Test POST is a series of the utilities from the Compaq SmartStart and Support Software CD, 4. To run , and then select Next. POST checks the following assemblies to run these utilities directly from the CD, 1. 3-6 Compaq ProLiant 6400R Maintenance ...and Service Guide To create diskette versions of diagnostic tests that the computer system is turned on the screen. Boot the Compaq SmartStart and Support Software CD. 2.
... PPMs Fans Power-On Self-Test POST is a series of the utilities from the Compaq SmartStart and Support Software CD, 4. To run , and then select Next. POST checks the following assemblies to run these utilities directly from the CD, 1. 3-6 Compaq ProLiant 6400R Maintenance ...and Service Guide To create diskette versions of diagnostic tests that the computer system is turned on the screen. Boot the Compaq SmartStart and Support Software CD. 2.
Compaq ProLiant 6400R Servers
Page 77
.... 1. Run Diagnostics to set the diskette type correctly. continued Make sure the diskette drive cables are assigned to COM1. Required fan not installed or spinning I /O Fan (Fan X) failure detected 2 short 2 short 2 short 2 short 2 short 2 short Probable Source of Problem Keyboard failure. (ZZ...ports are assigned to COM2, COM3, or COM4. Replace the part indicated. Replace failed assembly as indicated. 1. 3-10 Compaq ProLiant 6400R Maintenance and Service Guide Table 3-2 POST Error Messages continued Error Code Audible Beeps ZZ-301-Keyboard None Error 303-Keyboard ...
.... 1. Run Diagnostics to set the diskette type correctly. continued Make sure the diskette drive cables are assigned to COM1. Required fan not installed or spinning I /O Fan (Fan X) failure detected 2 short 2 short 2 short 2 short 2 short 2 short Probable Source of Problem Keyboard failure. (ZZ...ports are assigned to COM2, COM3, or COM4. Replace the part indicated. Replace failed assembly as indicated. 1. 3-10 Compaq ProLiant 6400R Maintenance and Service Guide Table 3-2 POST Error Messages continued Error Code Audible Beeps ZZ-301-Keyboard None Error 303-Keyboard ...